Visual function comparison of 2 aspheric multifocal intraocular lenses

被引:45
作者
Alfonso, Jose F. [1 ,2 ]
Fernandez-Vega, Luis [1 ,2 ]
Blazquez, Jose I. [1 ]
Montes-Mico, Robert [3 ]
机构
[1] Univ Oviedo, Sch Med, Fernandez Vega Ophthalmol Inst, Oviedo 33012, Spain
[2] Univ Oviedo, Sch Med, Dept Surg, Oviedo 33012, Spain
[3] Univ Valencia, Fac Phys, Dept Opt, Valencia, Spain
关键词
CONTRAST SENSITIVITY FUNCTION; BILATERAL IMPLANTATION; ACRYSOF RESTOR; PATIENT SATISFACTION; CLINICAL-OUTCOMES; MULTICENTER; DISTANCE; ACUITY; PERFORMANCE; EXCHANGE;
D O I
10.1016/j.jcrs.2011.08.034
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL). SETTING: Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN: Comparative case series. METHODS: Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured. RESULTS: The mean CDVA was 0.02 +/- 0.06 (SD) with the copolymer aspheric IOL and -0.06 +/- 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 +/- 0.06 and -0.09 +/- 0.06 logMAR, respectively. The DCNVA was better with the hybrid aspheric IOL (P<.05). The defocus curve showed that the hybrid aspheric IOL provided better visual acuity from 0.00 to -5.00 diopter (D) vergences (P<.05) except for -1.00 and -1.50 D, where the IOLs were comparable. Contrast sensitivity was better with the hybrid aspheric IOL at 12 cycles per degree (cpd) and 18 cpd under photopic conditions (P<.05). No significant differences were found under mesopic conditions (P>.05). CONCLUSIONS: Both IOL models gave good and comparable visual acuity at distance. However, the hybrid aspheric IOL provided better DCNVA than the copolymer aspheric IOL. Intermediate vision was not as good as distance and near and was similar between the 2 IOLs. Photopic contrast sensitivity was better with the hybrid aspheric IOL at high spatial frequencies and comparable between IOLs at low frequencies and under mesopic conditions.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 32 条
[1]   Prospective visual evaluation of apodized diffractive intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Mont-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1235-1243
[2]   Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens system [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Senaris, Ana ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02) :197-202
[3]   Outcomes and Patient Satisfaction After Presbyopic Bilateral Lens Exchange With the ReSTOR IOL in Emmetropic Patients [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (12) :927-933
[4]   Contrast Sensitivity Comparison Between AcrySof ReSTOR and Acri.LISA Aspheric Intraocular Lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Merayo, Carmen ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (07) :471-477
[5]   Intermediate visual function with different multifocal intraocular lens models [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Puchades, Cristina ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) :733-739
[6]   Visual function after implantation of an aspheric bifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Amhaz, Hussein ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :885-892
[7]   Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :672-676
[8]   Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution [J].
Alio, Jorge L. ;
Elkady, Bassarn ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :942-948
[9]   Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens [J].
Alio, Jorge L. ;
Pinero, David P. ;
Plaza-Puche, Ana B. ;
Joanna Rodriguez, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :241-250