Radiochromic film dosimetry of rectal inhomogeneity and applicator attenuation in high dose rate brachytherapy of uterine cervix

被引:0
作者
Uniyal, Satish C. [1 ,4 ]
Naithani, Umesh C. [2 ]
Sharma, Sunil D. [3 ]
Srivastava, Anoop K. [4 ]
机构
[1] HIHT Univ, Dept Radiol, Himalayan Inst Med Sci, Dehra Dun 248140, Uttarakhand, India
[2] HNB Garhwal Cent Univ, Dept Phys, Pauri Garhwal 246001, Uttarakhand, India
[3] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Bombay 400094, Maharashtra, India
[4] HIHT Univ, Canc Res Inst, Dehra Dun 248140, Uttarakhand, India
关键词
brachytherapy; dosimetry; treatment planning; film; Monte Carlo; RADIATION-THERAPY; INTERSTITIAL BRACHYTHERAPY; CARCINOMA; COMPLICATIONS; EBT; RECOMMENDATIONS; IRRADIATION; DELIVERY; BREAST; CANCER;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Heterogeneities existing in the patient during treatment are neglected, as the treated subject is considered homogeneous in most of the commercially-available treatment planning systems (TPSs) used for high dose rate (HDR) brachytherapy. The choice of a suitable dosimeter for experimental dosimetry near the HDR source is crucial, mainly due to existence of steep dose gradients. The present work aimed to assess the effect of rectal air heterogeneity and applicator attenuation in the HDR Ir-192 brachytherapy treatment of carcinoma uterine cervix by utilizing GAFCHROMIC EBT2 film dosimetry. The dose to rectal walls under the condition of rectal air heterogeneity was measured experimentally using EBT2 film in a rectal phantom, and the measurements were validated by the Monte Carlo (MC) simulations. The applicator attenuation was measured by EBT2 film for a commonly used stainless steel uterine tube in a homogeneous water equivalent phantom. The measured doses were compared with the TPS calculated values. In case of the air cavity, the measured dose at the closest rectal surface was 12.8% less than the TPS calculated value due to lack of back scattering, whereas at the farthest rectal surface, it was higher by 24.5% due to no attenuation. The magnitude of attenuation due to the metal applicator was measured as high as 2% when compared with the TPS calculation. The dose reduction at the nearest rectal surface due to the effect of rectal air has indicated a clinically favorable dose distribution within the rectum, whereas the shielding effect posed by the metallic applicator was found to be less significant. Mutual agreement of the measured doses with the MC calculated dose values confirmed the suitability of EBT2 film for clinical dosimetry in HDR brachytherapy.
引用
收藏
页码:66 / 75
页数:10
相关论文
共 30 条
[1]   Rectal bleeding after high-dose-rate brachytherapy combined with hypofractionated external-beam radiotherapy for localized prostate cancer: Impact of rectal dose in high-dose-rate brachytherapy on occurrence of grade 2 or worse rectal bleeding [J].
Akimoto, Tetsuo ;
Katoh, Hiroyuki ;
Kitamoto, Yoshizumi ;
Tamaki, Tomoaki ;
Harada, Kosaku ;
Shirai, Katsuyuki ;
Nakano, Takashi .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :364-370
[2]   A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT [J].
Andres, C. ;
del Castillo, A. ;
Tortosa, R. ;
Alonso, D. ;
Barquero, R. .
MEDICAL PHYSICS, 2010, 37 (12) :6271-6278
[3]  
[Anonymous], 1985, ICRU Report 38
[4]   Beta versus gamma dosimetry close to Ir-192 brachytherapy sources [J].
Baltas, D ;
Karaiskos, P ;
Papagiannis, P ;
Sakelliou, L ;
Loeffler, E ;
Zamboglou, N .
MEDICAL PHYSICS, 2001, 28 (09) :1875-1882
[5]   RECTAL COMPLICATIONS IN PATIENTS WITH CARCINOMA OF THE CERVIX TREATED WITH CONCOMITANT CISPLATIN AND EXTERNAL-BEAM IRRADIATION WITH HIGH-DOSE-RATE BRACHYTHERAPY - A DOSIMETRIC ANALYSIS [J].
CLARK, BG ;
SOUHAMI, L ;
ROMAN, TN ;
EVANS, MDC ;
PLA, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05) :1243-1250
[6]  
CULLEN D, 1997, EVALUATED PHOTON DAT, V6
[7]  
Daskalov Georgi M., 1998, MED PHYS, V25, P2200
[8]   Dosimetry of intracavitary applications in carcinoma of the cervix: Rectal dose analysis [J].
Deshpande, DD ;
Shrivastav, SK ;
Pradhan, AS ;
Viswanathan, PS ;
Dinshaw, KA .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (02) :163-166
[9]   Absorption spectroscopy of EBT model GAFCHROMIC™ film [J].
Devic, Slobodan ;
Tomic, Nada ;
Pang, Zhiyu ;
Seuntjens, Jan ;
Podgorsak, Ervin B. ;
Soares, Christopher G. .
MEDICAL PHYSICS, 2007, 34 (01) :112-118
[10]  
E Mainegra-Hing, 2005, PIRS801 NAT RES COUN