The aim of this work is to develop a high spatial resolution, high sensitivity, compact PET detector for small animal PET/MR imaging. The key design features are the use of trapezoidal slat crystals (TSC), the use of silicon photomultiplier (SiPM) arrays, and the use of a 3D statistics based positioning (SBP) algorithm. Through simulation, the performance of a detector module consisting of 8 trapezoidal 0.92 mm (0.63 mm) by 47.52 mm by 12 mm crystals readout by a 2x12 SiPM array was evaluated. A PET detector ring with a 57 mm inner ring diameter could be built using 32 of these detector modules. The average intrinsic spatial resolution in Y and X were 0.84 mm and 0.72 mm FHWM, respectively. There was a 28% miscoding error in X, mainly from Compton scatter in the crystal array. The Z or depth of interaction (DOI) resolution is 1.74 mm. The intrinsic spatial resolution is reasonably uniform across the whole detector module.
引用
收藏
页码:2598 / 2601
页数:4
相关论文
共 43 条
[31]   A GATE Monte Carlo model for a newly developed small animal PET scanner: the IRI-microPET [J].
Rad, S. Z. Islami ;
Peyvandi, R. Gholipour ;
Sadeghi, M. K. .
POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (02) :93-100
[32]   A Cone-Shaped Phantom for Assessment of Small Animal PET Scatter Fraction and Count Rate Performance [J].
Prasad, Rameshwar ;
Zaidi, Habib .
MOLECULAR IMAGING AND BIOLOGY, 2012, 14 (05) :561-571
[33]   Design Considerations for Double-Sided Silicon Strip Detectors Applicable to PET Imaging [J].
Studen, A. ;
Clinthorne, N. H. .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :3076-3081
[34]   Shine-Through in PET/MR Imaging: Effects of the Magnetic Field on Positron Range and Subsequent Image Artifacts [J].
Kolb, Armin ;
Sauter, Alexander W. ;
Eriksson, Lars ;
Vandenbrouke, Arne ;
Liu, Chih C. ;
Levin, Craig ;
Pichler, Bernd J. ;
Rafecas, Magdalena .
JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (06) :951-954
[35]   A PET detector module with monolithic crystal, single end readout, SiPM array and high depth-of-interaction resolution [J].
Zhang, H. ;
Zhou, R. ;
Yang, C. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[36]   A comparison of a Monte Carlo-based detection probability matrix with analytical probability matrix for small animal PET scanners [J].
Sarrhini, Otman ;
Bentourkia, M'hamed .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36 (04) :314-324
[37]   TOF Benefits and Trade-offs on Image Contrast-to-Noise Ratio Performance for a Small Animal PET Scanner [J].
Yussefian, Nikta Zarif ;
Toussaint, Maxime ;
Gaudin, Emilie ;
Lecomte, Roger ;
Fontaine, Rejean .
IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (05) :687-693
[38]   Misalignments calibration in small-animal PET scanners based on rotating planar detectors and parallel-beam geometry [J].
Abella, M. ;
Vicente, E. ;
Rodriguez-Ruano, A. ;
Espana, S. ;
Lage, E. ;
Desco, M. ;
Udias, J. M. ;
Vaquero, J. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22) :7493-7518
[39]   Simultaneous scanning of two mice in a small-animal PET scanner: a simulation-based assessment of the signal degradation [J].
Reilhac, Anthonin ;
Boisson, Frederic ;
Wimberley, Catriona ;
Parmar, Arvind ;
Zahra, David ;
Hamze, Hasar ;
Davis, Emma ;
Arthur, Andrew ;
Bouillot, Caroline ;
Charil, Arnaud ;
Gregoire, Marie-Claude .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03) :1371-1388
[40]   Assessment of reduced 18F-FDG dosage in pediatric PET/MR imaging through randomized down-sampling [J].
Tan, Xiaoyue ;
Zhou, Yongrong ;
Zhang, Qing ;
Yuan, Hui ;
Yao, Xinchao ;
Sun, Chang ;
Liu, Entao ;
Jiang, Lei .
ANNALS OF NUCLEAR MEDICINE, 2025,