Arthroscopic suture bridge transosseus equivalent fixation of rotator cuff tendon preserves intratendinous blood flow at the time of initial fixation

被引:102
作者
Christoforetti, John J. [1 ]
Krupp, Ryan J. [2 ]
Singleton, Steven B. [3 ]
Kissenberth, Michael J. [4 ,5 ]
Cook, Chad [6 ]
Hawkins, Richard J. [4 ,5 ]
机构
[1] Tristate Orthopaed & Sports Med Inc, Pittsburgh, PA 15237 USA
[2] Norton Orthopaed Specialists, Louisville, KY USA
[3] Spartanburg Reg Healthcare Syst, Spartanburg, SC USA
[4] Steadman Hawkins Clin Carolinas, Greenville, SC USA
[5] Steadman Hawkins Clin Carolinas, Spartanburg, SC USA
[6] Walsh Univ, N Canton, OH USA
关键词
Blood flow; doppler; laser; rotator cuff; surgery; LASER-DOPPLER FLOWMETRY; FULL-THICKNESS TEARS; STRUCTURAL FAILURE; ANCHOR REPAIR; SINGLE-ROW; SUPRASPINATUS; SHOULDER; PATTERNS; ANATOMY; TRIAL;
D O I
10.1016/j.jse.2011.02.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Current etiologic theories concerning healing rates in rotator cuff repair have focused on the blood supply in the tendinous portion of the cuff. We currently have little information regarding the effect of our repair techniques on this critical variable. We hypothesize that intratendinous blood flow is changed during transosseus equivalent tendon fixation. Methods: Eighteen consecutive patients with rotator cuff tears amenable to double row fixation were included in the study. Each patient underwent a standard arthroscopic transosseous equivalent double row fixation procedure using the Arthrex SutureBridge technique (Arthrex, Naples, FL, USA). After tying down of the medial row, a first set of recordings was taken using a custom laser doppler flowmetry probe (Perimed, Inc., Ohio, USA). A second recording was made following securing of the lateral PushLock anchors. The data were compared to determine the overall effect on blood flow associated with this technique. Results: Summated averages for the 2 groups show a significant (44.67%) decline in the blood flow present after the second row of implants are placed (P<.01). Individual calculations for regions of the cuff tear indicate significant differences in anterior third (P=.01), middle third (P<.01), and posterior third (P=.02) of the tear after transosseous equivalent fixation. Conclusion: Completion of the construct with lateral anchors in the transosseous equivalent technique results in reduced but preserved blood flow in the tendon repair site. Further study is required to determine the implications for tendon healing. Clinical relevance: Intratendinous blood flow is a variable that should be considered when evaluating repair methods in rotator cuff surgery. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 30 条
[1]   Rotator cuff tears:: The effect of the reconstruction method on three-dimensional repair site area [J].
Apreleva, M ;
Özbaydar, M ;
Fitzgibbons, PG ;
Warner, JJP .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (05) :519-526
[2]   Laser Doppler flowmetry in the assessment of tendon blood flow [J].
Åström, M .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2000, 10 (06) :365-367
[3]  
ASTROM M, 1994, CLIN ORTHOP RELAT R, P166
[4]  
Astrom M, 1991, SCAND J PLAST RECONS, V23, P213
[5]   Structure-function relationships in tendons: a review [J].
Benjamin, M. ;
Kaiser, E. ;
Milz, S. .
JOURNAL OF ANATOMY, 2008, 212 (03) :211-228
[6]   Micro circulation associated with degenerative rotator cuff lesions - In vivo assessment with orthogonal polarization spectral imaging during arthroscopy of the shoulder [J].
Biberthaler, P ;
Wiedemann, E ;
Nerlich, A ;
Kettler, A ;
Mussack, T ;
Deckelmann, S ;
Mutschler, W .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :475-480
[7]   Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal? [J].
Boileau, P ;
Brassart, N ;
Watkinson, DJ ;
Carles, M ;
Hatzidakis, AM ;
Krishnan, SG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) :1229-1240
[8]   A Prospective Randomized Clinical Trial Comparing Arthroscopic Single- and Double-Row Rotator Cuff Repair Magnetic Resonance Imaging and Early Clinical Evaluation [J].
Burks, Robert T. ;
Crim, Julia ;
Brown, Nick ;
Fink, Barbara ;
Greis, Patrick E. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (04) :674-682
[9]   TENDONS, LIGAMENTS, AND CAPSULE OF THE ROTATOR CUFF - GROSS AND MICROSCOPIC ANATOMY [J].
CLARK, JM ;
HARRYMAN, DT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :713-725
[10]   Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations [J].
Cole, Brian J. ;
ElAttrache, Neal S. ;
Anbari, Ammar .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (06) :662-669