High-resolution breast tomography at high energy: a feasibility study of phase contrast imaging on a whole breast

被引:47
作者
Sztrokay, A. [1 ]
Diemoz, P. C. [2 ,3 ]
Schlossbauer, T. [1 ]
Brun, E. [3 ]
Bamberg, F. [1 ]
Mayr, D. [4 ]
Reiser, M. F. [1 ]
Bravin, A. [3 ]
Coan, P. [1 ,2 ]
机构
[1] Univ Munich, Inst Clin Radiol, Munich, Germany
[2] Univ Munich, Fac Phys, Munich, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Univ Munich, Inst Pathol, D-8000 Munich, Germany
关键词
X-RAY; SYNCHROTRON-RADIATION; COMPUTED-TOMOGRAPHY; TABLE-TOP; MAMMOGRAPHY; CT; SCATTERING; REFRACTION; ABSORPTION; SPECIMENS;
D O I
10.1088/0031-9155/57/10/2931
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (> 12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92 x 92 mu m(2) pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.
引用
收藏
页码:2931 / 2942
页数:12
相关论文
共 34 条
[1]   2008 update of the guideline: early detection of breast cancer in Germany [J].
Albert, Ute-Susann ;
Altland, Helmut ;
Duda, Volker ;
Engel, Jutta ;
Geraedts, Max ;
Heywang-Koebrunner, Syvia ;
Hoelzel, Dieter ;
Kalbheim, Eva ;
Koller, Michael ;
Konig, Klaus ;
Kreienberg, Rolf ;
Kuehn, Thorsten ;
Lebeau, Annette ;
Nass-Griegoleit, Irmgard ;
Schlake, Werner ;
Schmutzler, Rita ;
Schreer, Ingrid ;
Schulte, Hilde ;
Schulz-Wendtland, Ruediger ;
Wagner, Uwe ;
Kopp, Ina .
JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2009, 135 (03) :339-354
[2]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[3]   Computed tomography for imaging the breast [J].
Boone, John M. ;
Kwan, Alex L. C. ;
Yang, Kai ;
Burkett, George W. ;
Lindfors, Karen K. ;
Nelson, Thomas R. .
JOURNAL OF MAMMARY GLAND BIOLOGY AND NEOPLASIA, 2006, 11 (02) :103-111
[4]   High-resolution CT by diffraction-enhanced x-ray imaging:: mapping of breast tissue samples and comparison with their histo-pathology [J].
Bravin, Alberto ;
Keyrilainen, Jani ;
Fernandez, Manuel ;
Fiedler, Stefan ;
Nemoz, Christian ;
Karjalainen-Lindsberg, Marja-Liisa ;
Tenhunen, Mikko ;
Virkkunen, Pekka ;
Leidenius, Marjut ;
von Smitten, Karl ;
Sipila, Petri ;
Suortti, Pekka .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08) :2197-2211
[5]   Mammography with Synchrotron Radiation: First Clinical Experience with Phase-Detection Technique [J].
Castelli, Edoardo ;
Tonutti, Maura ;
Arfelli, Fulvia ;
Longo, Renata ;
Quaia, Emilio ;
Rigon, Luigi ;
Sanabor, Daniela ;
Zanconati, Fabrizio ;
Dreossi, Diego ;
Abrami, Alessando ;
Quai, Elisa ;
Bregant, Paola ;
Casarin, Katia ;
Chenda, Valentina ;
Menk, Ralf Hendrik ;
Rokvic, Tatjana ;
Vascotto, Alessandro ;
Tromba, Giuliana ;
Cova, Maria Assunta .
RADIOLOGY, 2011, 259 (03) :684-694
[6]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[7]   Evaluation of imaging performance of a taper optics CCD 'FReLoN' camera designed for medical imaging [J].
Coan, P ;
Peterzol, A ;
Fiedler, S ;
Ponchut, C ;
Labiche, JC ;
Bravin, A .
JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 :260-270
[8]   Characterization of Osteoarthritic and Normal Human Patella Cartilage by Computed Tomography X-ray Phase-Contrast Imaging A Feasibility Study [J].
Coan, Paola ;
Bamberg, Fabian ;
Diemoz, Paul C. ;
Bravin, Alberto ;
Timpert, Kirsten ;
Muetzel, Elisabeth ;
Raya, Jose G. ;
Adam-Neumair, Silvia ;
Reiser, Maximilian F. ;
Glaser, Christian .
INVESTIGATIVE RADIOLOGY, 2010, 45 (07) :437-444
[9]   Analyzer-based imaging technique in tomography of cartilage and metal implants: A study at the ESRF [J].
Coan, Paola ;
Mollenhauer, Juergen ;
Wagner, Andreas ;
Muehleman, Carol ;
Bravin, Alberto .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :S41-S48
[10]   PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS [J].
DAVIS, TJ ;
GAO, D ;
GUREYEV, TE ;
STEVENSON, AW ;
WILKINS, SW .
NATURE, 1995, 373 (6515) :595-598