Wireless and Batteryless Blood Pressure Sensor

被引:0
作者
Sosa, J. [1 ]
Garcia-Alonso, S. [1 ]
Monzon-Verona, J. M.
Montiel-Nelson, J. A. [1 ]
Beriain, A. [2 ]
Fernandez, E. [2 ]
Solar, H. [2 ]
Garcia-Alonso, A. [2 ]
Gutierrez, I. [2 ]
机构
[1] Univ Las Palmas Gran Canaria, Dept Elect Engn & Automat, E-35017 Las Palmas Gran Canaria, Spain
[2] Univ Navarra, CElT, COMMIC, San Sebastian, Spain
来源
2011 IEEE 54TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS) | 2011年
关键词
OPTIMIZATION; MICROSYSTEM; MEMS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A low-power invasive blood pressure transducer has been designed. It is based on a structure of four high resistive strain gauges in a full Wheatstone bridge configuration. For obtaining the required sensitivity, the gauge was allocated performing a careful mechanical simulation of the membrane behaviour. The electronic conditioning circuit and the ADC were optimized to compensate the noise introduced by the high resistive gauges. A batteryless RFID tag designed to incorporate and to supply the sensor was fabricated and measured. It power supplies the sensor at a distance longer than 50 cm from a standard reader, while the reported ranges -to the best of our knowledge- are shorter than 10 cm. This wireless and batteryless sensor is especially suitable for surgery rooms and intensive care units.
引用
收藏
页数:4
相关论文
共 20 条
  • [1] Barlian A.A., 2009, IEEE P, V97
  • [2] Bryzek J., 2005, INSTRUMENTATION MEAS, V7, P51
  • [3] Cangialosi A., 2007, COMMUNICATIONS MAGAZ, V46, P18
  • [4] Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent
    Chow, Eric Y.
    Chlebowski, Arthur L.
    Chakraborty, Sudipto
    Chappell, William J.
    Irazoqui, Pedro P.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (06) : 1487 - 1496
  • [5] Wireless Batteryless Implantable Blood Pressure Monitoring Microsystem for Small Laboratory Animals
    Cong, Peng
    Ko, Wen H.
    Young, Darrin J.
    [J]. IEEE SENSORS JOURNAL, 2010, 10 (02) : 243 - 254
  • [6] A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring
    Cong, Peng
    Chaimanonart, Nattapon
    Ko, Wen H.
    Young, Darrin J.
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (12) : 3631 - 3644
  • [7] Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization
    Enz, CC
    Temes, GC
    [J]. PROCEEDINGS OF THE IEEE, 1996, 84 (11) : 1584 - 1614
  • [8] EPCglobal, 2008, Epc radio-frequency identity protocols class-1 generation-2 uhf rfid protocol for communications at 860 mhz-960 mhz version 1.2.0
  • [9] Herrera-May AL, 2009, REV MEX FIS, V55, P14
  • [10] RF-MEMS for wireless communications
    Hilbert, Jeffrey L.
    [J]. IEEE COMMUNICATIONS MAGAZINE, 2008, 46 (08) : 68 - 74