The Munich Compact Light Source: initial performance measures

被引:87
|
作者
Eggl, Elena [1 ]
Dierolf, Martin [1 ]
Achterhold, Klaus [1 ]
Jud, Christoph [1 ]
Guenther, Benedikt [1 ,2 ]
Braig, Eva [1 ]
Gleich, Bernhard [3 ]
Pfeiffer, Franz [1 ,4 ]
机构
[1] Tech Univ Munich, Phys Dept, James Franck Str 1, D-85748 Garching, Germany
[2] Max Planck Inst Quantum Opt, Hans Kopfermann Str 1, D-85748 Garching, Germany
[3] Tech Univ Munich, Inst Med Tech, Boltzmannstr 11, D-85748 Garching, Germany
[4] Tech Univ Munich, Inst Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
来源
JOURNAL OF SYNCHROTRON RADIATION | 2016年 / 23卷
基金
欧洲研究理事会;
关键词
inverse Compton X-rays; compact synchrotron; X-ray imaging; TOMOGRAPHY;
D O I
10.1107/S160057751600967X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hardening artifacts for imaging experiments. Over the last decade, compact synchrotron sources based on inverse Compton scattering have evolved as one of the most promising types of laboratory-scale X-ray sources: they provide a performance and brilliance that lie in between those of large-scale synchrotron sources and X-ray tube sources, with significantly reduced financial and spatial requirements. These sources produce X-rays through the collision of relativistic electrons with infrared laser photons. In this study, an analysis of the performance, such as X-ray flux, source size and spectra, of the first commercially sold compact light source, the Munich Compact Light Source, is presented.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 50 条
  • [41] Quantitative X-ray phase-contrast microtomography from a compact laser-driven betatron source
    Wenz, J.
    Schleede, S.
    Khrennikov, K.
    Bech, M.
    Thibault, P.
    Heigoldt, M.
    Pfeiffer, F.
    Karsch, S.
    NATURE COMMUNICATIONS, 2015, 6
  • [42] Tomography with compact laser plasma double-stream gas-puff target source of the EUV and SXR radiation
    Wachulak, P.
    Arikkatt, A. J.
    Bartnik, A.
    Wegrzynski, L.
    Fiedorowicz, H.
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE VI, 2019, 11032
  • [43] Biological Applications of Short Wavelength Microscopy Based on Compact, Laser-Produced Gas-Puff Plasma Source
    Torrisi, Alfio
    Wachulak, Przemyslaw W.
    Bartnik, Andrzej
    Wegrzynski, Lukasz
    Fok, Tomasz
    Fiedorowicz, Henryk
    APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 32
  • [44] Spatially modulated light source obliquely incident on a semi-infinite scattering medium
    Liemert, Andre
    Kienle, Alwin
    OPTICS LETTERS, 2012, 37 (19) : 4158 - 4160
  • [45] I12: the Joint Engineering, Environment and Processing (JEEP) beamline at Diamond Light Source
    Drakopoulos, Michael
    Connolley, Thomas
    Reinhard, Christina
    Atwood, Robert
    Magdysyuk, Oxana
    Vo, Nghia
    Hart, Michael
    Connor, Leigh
    Humphreys, Bob
    Howell, George
    Davies, Steve
    Hill, Tim
    Wilkin, Guy
    Pedersen, Ulrik
    Foster, Andrew
    De Maio, Nicoletta
    Basham, Mark
    Yuan, Fajin
    Wanelik, Kaz
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 828 - 838
  • [46] Development and applications of a phase contrast imaging and tomography facility (PCIT) at Singapore Synchrotron Light Source
    Cholewa, M.
    Ping, Yang
    Ling, Ng May
    Juan, Li Zhi
    Yeukuang, Hwu
    Moser, H. O.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 844 - +
  • [47] Variable optical activation of human cone photoreceptors visualized using a short coherence light source
    Rha, Jungtae
    Schroeder, Brett
    Godara, Pooja
    Carroll, Joseph
    OPTICS LETTERS, 2009, 34 (24) : 3782 - 3784
  • [48] FEATURES ON INITIAL COMPUTED-TOMOGRAPHY SCAN OF INFARCTS WITH A CARDIAC SOURCE OF EMBOLISM IN THE NINDS-STROKE-DATA-BANK
    KITTNER, SJ
    SHARKNESS, CM
    SLOAN, MA
    PRICE, TR
    DAMBROSIA, JM
    TUHRIM, S
    WOLF, PA
    MOHR, JP
    HIER, DB
    STROKE, 1992, 23 (12) : 1748 - 1751
  • [49] Morphological and Performance Measures of Polyurethane Foams Using X-Ray CT and Mechanical Testing
    Patterson, Brian M.
    Henderson, Kevin
    Gilbertson, Robert D.
    Tornga, Stephanie
    Cordes, Nikolaus L.
    Chavez, Manuel E.
    Smith, Zachary
    MICROSCOPY AND MICROANALYSIS, 2014, 20 (04) : 1284 - 1293
  • [50] X-ray imaging of a small electron beam in a low-emittance synchrotron light source
    Takano, S
    Masaki, M
    Ohkuma, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01) : 357 - 370