The Munich Compact Light Source: initial performance measures

被引:87
|
作者
Eggl, Elena [1 ]
Dierolf, Martin [1 ]
Achterhold, Klaus [1 ]
Jud, Christoph [1 ]
Guenther, Benedikt [1 ,2 ]
Braig, Eva [1 ]
Gleich, Bernhard [3 ]
Pfeiffer, Franz [1 ,4 ]
机构
[1] Tech Univ Munich, Phys Dept, James Franck Str 1, D-85748 Garching, Germany
[2] Max Planck Inst Quantum Opt, Hans Kopfermann Str 1, D-85748 Garching, Germany
[3] Tech Univ Munich, Inst Med Tech, Boltzmannstr 11, D-85748 Garching, Germany
[4] Tech Univ Munich, Inst Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
来源
JOURNAL OF SYNCHROTRON RADIATION | 2016年 / 23卷
基金
欧洲研究理事会;
关键词
inverse Compton X-rays; compact synchrotron; X-ray imaging; TOMOGRAPHY;
D O I
10.1107/S160057751600967X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hardening artifacts for imaging experiments. Over the last decade, compact synchrotron sources based on inverse Compton scattering have evolved as one of the most promising types of laboratory-scale X-ray sources: they provide a performance and brilliance that lie in between those of large-scale synchrotron sources and X-ray tube sources, with significantly reduced financial and spatial requirements. These sources produce X-rays through the collision of relativistic electrons with infrared laser photons. In this study, an analysis of the performance, such as X-ray flux, source size and spectra, of the first commercially sold compact light source, the Munich Compact Light Source, is presented.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 50 条
  • [1] The versatile X-ray beamline of the Munich Compact Light Source: design, instrumentation and applications
    Guenther, Benedikt
    Gradl, Regine
    Jud, Christoph
    Eggl, Elena
    Huang, Juanjuan
    Kulpe, Stephanie
    Achterhold, Klaus
    Gleich, Bernhard
    Dierolf, Martin
    Pfeiffer, Franz
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1395 - 1414
  • [2] Mono-Energy Coronary Angiography with a Compact Light Source
    Eggl, Elena
    Meehlem, Korbinian
    Braig, Eva
    Kulpe, Stephanie
    Dierolf, Martin
    Guenther, Benedikt
    Achterhold, Klaus
    Herzen, Julia
    Gleich, Bernhard
    Rummeny, Ernst
    Noel, Peter B.
    Pfeiffer, Franz
    Muenzel, Daniela
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [3] Multimodal hard X-ray imaging of a mammography phantom at a compact synchrotron light source
    Schleede, Simone
    Bech, Martin
    Achterhold, Klaus
    Potdevin, Guillaume
    Gifford, Martin
    Loewen, Rod
    Limborg, Cecile
    Ruth, Ronald
    Pfeiffer, Franz
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 525 - 529
  • [4] Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays
    Bech, Martin
    Bunk, Oliver
    David, Christian
    Ruth, Ronald
    Rifkin, Jeff
    Loewen, Rod
    Feidenhans'l, Robert
    Pfeiffer, Franz
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 43 - 47
  • [5] Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source
    Schleede, Simone
    Meinel, Felix G.
    Bech, Martin
    Herzen, Julia
    Achterhold, Klaus
    Potdevin, Guillaume
    Malecki, Andreas
    Adam-Neumair, Silvia
    Thieme, Sven F.
    Bamberg, Fabian
    Nikolaou, Konstantin
    Bohla, Alexander
    Yildirim, Ali Oe.
    Loewen, Roderick
    Gifford, Martin
    Ruth, Ronald
    Eickelberg, Oliver
    Reiser, Maximilian
    Pfeiffer, Franz
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (44) : 17880 - 17885
  • [6] Propagation-based Phase-Contrast X-ray Imaging at a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Hehn, Lorenz
    Guenther, Benedikt
    Yildirim, Ali Oender
    Gleich, Bernhard
    Achterhold, Klaus
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2017, 7
  • [7] In vivo Dynamic Phase-Contrast X-ray Imaging using a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Guenther, Benedikt
    Hehn, Lorenz
    Moeller, Winfried
    Kutschke, David
    Yang, Lin
    Donnelley, Martin
    Murrie, Rhiannon
    Erl, Alexander
    Stoeger, Tobias
    Gleich, Bernhard
    Achterhold, Klaus
    Schmid, Otmar
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2018, 8
  • [8] A compact, sample-in-atmospheric-pressure soft x-ray microscope developed at Pohang Light Source
    Lim, Jun
    Shin, Hyun-Joon
    Chae, Keun Hwa
    Hwang, Chan-Cuk
    Hwang, Han-Na
    Hong, Chung Ki
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (06)
  • [9] Tomographic imaging with the use of a compact soft X-ray microscope based on a laser plasma light source
    Wachulak, P. W.
    Torrisi, A.
    Krauze, W.
    Bartnik, A.
    Kostecki, J.
    Maisano, M.
    Fiedorowicz, H.
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE VI, 2019, 11032
  • [10] A compact light source providing high-flux, quasi-monochromatic, tunable X-rays in the laboratory
    Hornberger, Benjamin
    Kasahara, Jack
    Gifford, Martin
    Ruth, Ronald
    Loewen, Rod
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII, 2019, 11110