Performance Evaluation of PV Interfaced Z-Source-Network-Based Shunt Active Power Filter

被引:1
|
作者
Sellakumar, S. [1 ]
Vijayakumar, M. [2 ]
机构
[1] Jeppiaar Engn Coll, Dept Elect & Elect Engn, Madras 600119, Tamil Nadu, India
[2] JNTU Ananthapur Univ, Anantapur 515002, Andhra Pradesh, India
关键词
photovoltaic system; second-order generalized integrator; shunt active power filter; voltage source inverter; total harmonic distortion; Z-SOURCE INVERTER; QUALITY CONDITIONER; ENERGY-STORAGE; REACTIVE POWER; VOLTAGE; COMPENSATION; DESIGN; BOOST; TIME;
D O I
10.1520/JTE20160260
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, a photovoltaic supported Z-source-inverter (ZSI)-based shunt active power filter (SAPF) is proposed for power-quality improvement. The topology has a voltage source inverter (VSI), which is connected in parallel with the point of common coupling (PCC), and is assisted by an impedance network. The Z-source network is really a distinct impedance network to facilitate interconnection between the photovoltaic (PV) power-generating system and VSI. The key features of ZSI can boost up the changeable dc voltage into any specified AC output voltage, decrease the components required, and mitigate harmonic content. The compensation capability of the SAPF mainly depends on the control scheme utilized to reference current generations. In addition, the control scheme decides a number of sensor essential and measurement practices; thus, it also estimates the cost of the topology. In this proposed system, second-order generalized integrator (SOGI) is employed to extract the reference current of SAPF. The SOGI-based control scheme uses only the measurement of the converter, and load current as the feedback signals therefore does not need voltage measurement and sensors. The proposed SAPF topology utilizes an alternative energy source having an energy storage unit to compensate the long-term current disturbances and voltage interruption and mete out the active power requirement of the utility grid. The PV-supported ZSI-based SAPF tested with various kinds of loads can examine the performance of the system under steady and dynamic state conditions. To verify the effectiveness of the proposed control scheme and PV-supported SAPF topology, the simulation and experimental results are presented.
引用
收藏
页码:2151 / 2165
页数:15
相关论文
共 50 条
  • [31] A Shunt Active Power Filter With Enhanced Performance Using ANN-Based Predictive and Adaptive Controllers
    Bhattacharya, Avik
    Chakraborty, Chandan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (02) : 421 - 428
  • [32] Modified SOGI based shunt active power filter to tackle various grid voltage abnormalities
    Patil, Kalpeshkumar
    Patel, Hiren H.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2017, 20 (05): : 1466 - 1474
  • [33] Performance Evaluation of LLCL Filter for Active Power Filter
    Buyuk, Mehmet
    Inci, Mustafa
    Tumay, Mehmet
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [34] A MULTI-OBJECTIVE OPTIMIZATION FOR PERFORMANCE IMPROVEMENT OF THE Z-SOURCE ACTIVE POWER FILTER
    Hosseini, Seyed Mohsen
    Beromi, Yousef Alinejad
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2016, 67 (05): : 358 - 364
  • [35] Shunt Active Power Filter Based on Savitzky-Golay Filter: Pragmatic Modelling and Performance Validation
    Hasan, Kamrul
    Othman, Muhammad Murtadha
    Meraj, Sheikh Tanzim
    Mekhilef, Saad
    Abidin, Ahmad Farid Bin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (07) : 8838 - 8850
  • [36] Experimental validation of solar PV sustained ZSI based Unified Active Power Filter for enrichment of power quality
    Parthiban, S.
    Vijayakumar, M.
    AUTOMATIKA, 2021, 62 (01) : 154 - 171
  • [37] Investigations on Split-Source Inverter Based Shunt Active Power Filter Integrated Microgrid System for Improvement of Power Quality Issues
    Barik, Prasanta Kumar
    Shankar, Gauri
    Sahoo, Pradeepta Kumar
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (04) : 2025 - 2047
  • [38] Synergetic control for three-level voltage source inverter-based shunt active power filter to improve power quality
    Deffaf, Brahim
    Farid, Hamoudi
    Benbouhenni, Habib
    Medjmadj, Slimane
    Debdouche, Naamane
    ENERGY REPORTS, 2023, 10 : 1013 - 1027
  • [39] Solar PV Based Shunt Active Filter with p-q Theory Control for Improvement of Power Quality
    Balamurugan, R.
    Nithya, R.
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2017, 26 (09)
  • [40] A Novel Hybrid Switching Scheme based Implementation of Shunt Active Power Filter
    Chandwani, Ashwin
    Mallik, Ayan
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 1205 - 1210