Standardized Aortic Valve Neocuspidization for Treatment of Aortic Valve Diseases

被引:11
作者
Amabile, Andrea
Krane, Markus
Dufendach, Keith
Baird, Christopher W.
Ganjoo, Nikhil
Eckstein, Friedrich S.
Albertini, Alberto
Gruber, Peter J.
Mumtaz, Mubashir A.
Bacha, Emile A.
Benedetto, Umberto
Chikwe, Joanna
Geirsson, Arnar
Holfeld, Johannes
Iida, Yasunori
Lange, Rudiger
Morell, Victor O.
Chu, Danny [1 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Cardiothorac Surg, Div Cardiac Surg, 200 Lothrop St,Ste C-700, Pittsburgh, PA 15213 USA
关键词
PROSTHESIS-PATIENT MISMATCH; HEMODYNAMIC PERFORMANCE; AUTOLOGOUS PERICARDIUM; RAPID DEPLOYMENT; REPLACEMENT; RECONSTRUCTION; BIOPROSTHESIS; EXPERIENCE; OUTCOMES; REPAIR;
D O I
10.1016/j.athoracsur.2022.03.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Aortic valve replacement is the traditional surgical treatment for aortic valve diseases, yet standardized aortic valve neocuspidization (AVNeo) is a promising alternative that is gaining popularity. The purpose of this article is to review the available published literature of AVNeo using glutaraldehyde-treated autologous pericardium, also known as the Ozaki procedure, including indications, outcomes, potential benefits, and modes of failure for the reconstructed valve.METHODS A comprehensive literature search was performed using keywords related to aortic valve repair, AVNeo, or Ozaki procedure. All articles describing performance of AVNeo were reviewed. RESULTS Reported early mortality after AVNeo varies from 0% to 5.88%. The largest cohort of patients in the literature includes 850 patients with an inhospital mortality rate of 1.88%. Cumulative incidence of aortic valve reoperation was 4.2% in the largest series. Reoperation was uncommon and mainly due to infective endo-carditis or degeneration of the reconstructed valve (most commonly due to aortic valve regurgitation, rather than stenosis).CONCLUSIONS Aortic valve neocuspidization is a versatile and standardized alternative to aortic valve replacement with a biological prosthesis. Early to midterm outcomes from a number of centers are excellent and demonstrate the safety and durability of the procedure. Long-term outcomes and clinical trial data are necessary to determine which patients benefit the most from this procedure.(Ann Thorac Surg 2022;114:1108-17)(c) 2022 by The Society of Thoracic Surgeons
引用
收藏
页码:1108 / 1117
页数:10
相关论文
共 58 条
[21]   Biological Characterization of Human Autologous Pericardium Treated with the Ozaki Procedure for Aortic Valve Reconstruction [J].
Gardin, Chiara ;
Morciano, Giampaolo ;
Ferroni, Letizia ;
Mikus, Elisa ;
Tripodi, Alberto ;
Pin, Maurizio ;
Tremoli, Elena ;
Albertini, Alberto ;
Zavan, Barbara .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (17)
[22]   Long-term Outcomes Associated With Permanent Pacemaker Implantation After Surgical Aortic Valve Replacement [J].
Glaser, Natalie ;
Persson, Michael ;
Dalen, Magnus ;
Sartipy, Ulrik .
JAMA NETWORK OPEN, 2021, 4 (07) :E2116564
[23]   Aortic valve replacement with mechanical vs. biological prostheses in patients aged 50-69 years [J].
Glaser, Natalie ;
Jackson, Veronica ;
Holzmann, Martin J. ;
Franco-Cereceda, Anders ;
Sartipy, Ulrik .
EUROPEAN HEART JOURNAL, 2016, 37 (34) :2658-2667
[24]   Mechanical or Biologic Prostheses for Aortic-Valve and Mitral-Valve Replacement [J].
Goldstone, Andrew B. ;
Chiu, Peter ;
Baiocchi, Michael ;
Lingala, Bharathi ;
Patrick, William L. ;
Fischbein, Michael P. ;
Woo, Y. Joseph .
NEW ENGLAND JOURNAL OF MEDICINE, 2017, 377 (19) :1847-1857
[25]   Midterm results after aortic valve replacement with the autologous tissue cardiac valve [J].
Gross, C ;
Simon, P ;
Grabenwöger, M ;
Mair, R ;
Sihorsch, K ;
Kypta, A ;
Grimm, M ;
Brücke, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 16 (05) :533-539
[26]   Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve? [J].
Halees, ZA ;
Shahid, MA ;
Sanei, AA ;
Sallehuddin, A ;
Duran, C .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (02) :200-205
[27]   Reconstruction of aortic valve by autologous pericardium (Ozaki's procedure): Single center experience in Vietnam [J].
Hung Thanh Ngo ;
Huu Cong Nguyen ;
Thuy Tran Nguyen ;
Thanh Ngoc Le ;
Camilleri, Lionel ;
Hung Quoc Doan .
ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2021, 29 (05) :394-399
[28]   Aortic valve neocuspidization in patients under 65 years old [J].
Iida, Yasunori ;
Sawa, Shigeharu ;
Fujii, Susumu ;
Shimizu, Hideyuki .
GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (08) :780-784
[29]   Early and mid-term results of isolated aortic valve neocuspidization in patients with aortic stenosis [J].
Iida, Yasunori ;
Fujii, Susumu ;
Akiyama, Sho ;
Sawa, Shigeharu .
GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2018, 66 (11) :648-652
[30]   The BASILICA Trial Prospective Multicenter Investigation of Intentional Leaflet Laceration to Prevent TAVR Coronary Obstruction [J].
Khan, Jaffar M. ;
Greenbaum, Adam B. ;
Babaliaros, Vasilis C. ;
Rogers, Toby ;
Eng, Marvin H. ;
Paone, Gaetano ;
Leshnower, Bradley G. ;
Reisman, Mark ;
Satler, Lowell ;
Waksman, Ron ;
Chen, Marcus Y. ;
Stine, Annette M. ;
Tian, Xin ;
Dvir, Danny ;
Lederman, Robert J. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (13) :1240-1252