Standardized Aortic Valve Neocuspidization for Treatment of Aortic Valve Diseases

被引:8
作者
Amabile, Andrea
Krane, Markus
Dufendach, Keith
Baird, Christopher W.
Ganjoo, Nikhil
Eckstein, Friedrich S.
Albertini, Alberto
Gruber, Peter J.
Mumtaz, Mubashir A.
Bacha, Emile A.
Benedetto, Umberto
Chikwe, Joanna
Geirsson, Arnar
Holfeld, Johannes
Iida, Yasunori
Lange, Rudiger
Morell, Victor O.
Chu, Danny [1 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Cardiothorac Surg, Div Cardiac Surg, 200 Lothrop St,Ste C-700, Pittsburgh, PA 15213 USA
关键词
PROSTHESIS-PATIENT MISMATCH; HEMODYNAMIC PERFORMANCE; AUTOLOGOUS PERICARDIUM; RAPID DEPLOYMENT; REPLACEMENT; RECONSTRUCTION; BIOPROSTHESIS; EXPERIENCE; OUTCOMES; REPAIR;
D O I
10.1016/j.athoracsur.2022.03.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Aortic valve replacement is the traditional surgical treatment for aortic valve diseases, yet standardized aortic valve neocuspidization (AVNeo) is a promising alternative that is gaining popularity. The purpose of this article is to review the available published literature of AVNeo using glutaraldehyde-treated autologous pericardium, also known as the Ozaki procedure, including indications, outcomes, potential benefits, and modes of failure for the reconstructed valve.METHODS A comprehensive literature search was performed using keywords related to aortic valve repair, AVNeo, or Ozaki procedure. All articles describing performance of AVNeo were reviewed. RESULTS Reported early mortality after AVNeo varies from 0% to 5.88%. The largest cohort of patients in the literature includes 850 patients with an inhospital mortality rate of 1.88%. Cumulative incidence of aortic valve reoperation was 4.2% in the largest series. Reoperation was uncommon and mainly due to infective endo-carditis or degeneration of the reconstructed valve (most commonly due to aortic valve regurgitation, rather than stenosis).CONCLUSIONS Aortic valve neocuspidization is a versatile and standardized alternative to aortic valve replacement with a biological prosthesis. Early to midterm outcomes from a number of centers are excellent and demonstrate the safety and durability of the procedure. Long-term outcomes and clinical trial data are necessary to determine which patients benefit the most from this procedure.(Ann Thorac Surg 2022;114:1108-17)(c) 2022 by The Society of Thoracic Surgeons
引用
收藏
页码:1108 / 1117
页数:10
相关论文
共 58 条
  • [1] Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve
    Aicher, Diana
    Kunihara, Takashi
    Abou Issa, Omar
    Brittner, Brigitte
    Graeber, Stefan
    Schaefers, Hans-Joachim
    [J]. CIRCULATION, 2011, 123 (02) : 178 - 185
  • [2] Midterm outcome of aortic valve neocuspidization for aortic valve stenosis with small annulus
    Akiyama, Sho
    Iida, Yasunori
    Shimura, Kazuma
    Fujii, Susumu
    Shimizu, Hideyuki
    Sawa, Shigeharu
    [J]. GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (08) : 762 - 767
  • [3] Intermediate-term outcome of 500 consecutive rapid-deployment surgical aortic valve procedures
    Andreas, Martin
    Coti, Iuliana
    Rosenhek, Raphael
    Shabanian, Shiva
    Mahr, Stephane
    Uyanik-Uenal, Keziban
    Wiedemann, Dominik
    Binder, Thomas
    Kocher, Alfred
    Laufer, Guenther
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 55 (03) : 527 - 533
  • [4] Congenital aortic and truncal valve reconstruction using the Ozaki technique: Short-term clinical results
    Baird, Christopher W.
    Cooney, Brenda
    Chavez, Mariana
    Sleeper, Lynn A.
    Marx, Gerald R.
    del Nido, Pedro J.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 161 (05) : 1567 - 1577
  • [5] Aortic valve neo-cuspidation using the Ozaki technique for acquired and congenital disease: where does this procedure currently stand?
    Baird, Christopher W.
    Marathe, Supreet P.
    del Nido, Pedro J.
    [J]. INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 36 (Suppl 1) : 113 - 122
  • [6] Bashir Mohamad, 2014, Aorta (Stamford), V2, P1, DOI 10.12945/j.aorta.2014.14-005
  • [7] Aortic valve neocuspidization with autologous pericardium in adult patients: UK experience and meta-analytic comparison with other aortic valve substitutes
    Benedetto, Umberto
    Sinha, Shubhra
    Dimagli, Arnaldo
    Dixon, Lauren
    Stoica, Serban
    Cocomello, Lucia
    Quarto, Cesare
    Angelini, Gianni D.
    Dandekar, Uday
    Caputo, Massimo
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2021, 60 (01) : 34 - 46
  • [8] Patient-prosthesis mismatch following aortic valve replacement
    Bilkhu, Rajdeep
    Jahangiri, Marjan
    Otto, Catherine M.
    [J]. HEART, 2019, 105 : S28 - S33
  • [9] BJORK VO, 1964, J THORAC CARDIOV SUR, V47, P693
  • [10] Very Long-Term Outcomes of the Carpentier-Edwards Perimount Valve in Aortic Position
    Bourguignon, Thierry
    Bouquiaux-Stablo, Anne-Lorraine
    Candolfi, Pascal
    Mirza, Alain
    Loardi, Claudia
    May, Marc-Antoine
    El-Khoury, Rym
    Marchand, Michel
    Aupart, Michel
    [J]. ANNALS OF THORACIC SURGERY, 2015, 99 (03) : 831 - 837