High-Temperature Ignition Kinetics of Gas Turbine Lubricating Oils

被引:6
作者
Cooper, Sean P. [1 ]
Petersen, Eric L. [1 ]
机构
[1] Texas A&M Univ, J Mike Walker 66 Dept Mech Engn, College Stn, TX 77843 USA
来源
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME | 2021年 / 143卷 / 11期
关键词
lubricating oil; auto-ignition; shock tube; spray injection; chemical kinetics; SHOCK-TUBE; JET; COMBUSTION; PRESSURES; SURROGATE; FACILITY; OCTANE;
D O I
10.1115/1.4051985
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Lubricant ignition is a highly undesirable event in any mechanical system, and surprisingly minimal work has been conducted to investigate the auto-ignition properties of gas turbine lubricants. To this end, using a recently established spray injection scheme in a shock tube, two gas turbine lubricants (Mobil DTE 732 and Lubricant A from Cooper et al. 2021, "Auto-Ignition of Gas Turbine Lubricating Oils in a Shock Tube Using Spray Injection," ASME J. Eng. Gas Turbines Power, 143(5), p. 051008) were subjected to high-temperature, post-reflected-shock conditions, and OH* chemiluminescence was monitored at the sidewall location of the shock tube to measure ignition delay time (tau(ign)). A combination of an extended shock-tube driver and driver-gas tailoring were utilized to observe ignition between 1183K and 1385K at near-atmospheric pressures. A clear, two-stage-ignition process was observed for all tests with Mobil DTE 732, and both first and second stage tau(ign )are compared. Second stage ignition was found to be more indicative of lubricant ignition and was used to compare tau(ign )values with lubricant A. Both lubricants exhibit three ignition regimes: a high-temperature, Arrhenius-like regime (>1275 K); an intermediate, negative-temperature-coefficient-like regime (1230 -1275 K); and a low-temperature ignition regime (<1230 K). Similar tau(ign )behavior in the high-temperature regime was seen for both lubricants, and a regression analysis using tau(ign )data from both lubricants in this region produced the Arrhenius expression tau(ign)(mu s) = 4.4 x 10(-14) exp(96.7(kcal/mol)/RT). While lubricant A was found to be less reactive in the intermediate-temperature regime, Mobil DTE 732 was less reactive in the low-temperature regime. As the low-temperature regime is more relevant to gas turbine conditions, Mobil DTE 732 is considered more desirable for system implementation. Chemical kinetic modeling was also performed using n-hexadecane models (a lubricant surrogate suggested in the literature). The current models are unable to reproduce the three regimes observed and predict activation energies much lower than those observed in the high-temperature regime, suggesting n-hexadecane is a poor surrogate for lubricant ignition. Additionally, experiments were conducted with Jet-A for temperatures between 1145 and 1419 K around 1 atm. Good agreement is seen with both literature data and model predictions, anchoring the experiment with previously established tau(ign )measurement methods and calculations. A linear regression analysis of the Jet-A data produced the Arrhenius expression: tau(ign)(mu s) = 6.39 x 10(-5) exp(41.4(kcal/mol)/RT).
引用
收藏
页数:8
相关论文
共 35 条
[21]  
Mullins B. P., 1953, Fuel, Land, V32, P363
[22]  
Mulvihill C.R., 2019, THESIS A M U COLL ST
[23]   A component library framework for deriving kinetic mechanisms for multi-component fuel surrogates: Application for jet fuel surrogates [J].
Narayanaswamy, Krithika ;
Pitsch, Heinz ;
Pepiot, Perrine .
COMBUSTION AND FLAME, 2016, 165 :288-309
[24]   Impact of shock-tube facility-dependent effects on incident- and reflected-shock conditions over a wide range of pressures and Mach numbers [J].
Nativel, Damien ;
Cooper, Sean P. ;
Lipkowicz, Timo ;
Fikri, Mustapha ;
Petersen, Eric L. ;
Schulz, Christof .
COMBUSTION AND FLAME, 2020, 217 :200-211
[25]   A facility for gas- and condensed-phase measurements behind shock waves [J].
Petersen, EL ;
Rickard, MJA ;
Crofton, MW ;
Abbey, ED ;
Traum, MJ ;
Kalitan, DM .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (09) :1716-1729
[26]   INTERPRETING ENDWALL AND SIDEWALL MEASUREMENTS IN SHOCK-TUBE IGNITION STUDIES [J].
Petersen, Eric L. .
COMBUSTION SCIENCE AND TECHNOLOGY, 2009, 181 (09) :1123-1144
[27]   High Pressure Shock Tube Ignition Delay Time Measurements During Oxy-Methane Combustion With High Levels of CO2 Dilution [J].
Pryor, Owen ;
Barak, Samuel ;
Lopez, Joseph ;
Ninnemann, Erik ;
Koroglu, Batikan ;
Nash, Leigh ;
Vasu, Subith .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2017, 139 (04)
[28]   Reduced Kinetic Schemes of Complex Reaction Systems: Fossil and Biomass-Derived Transportation Fuels [J].
Ranzi, Eliseo ;
Frassoldati, Alessio ;
Stagni, Alessandro ;
Pelucchi, Matteo ;
Cuoci, Alberto ;
Faravelli, Tiziano .
INTERNATIONAL JOURNAL OF CHEMICAL KINETICS, 2014, 46 (09) :512-542
[29]   Prevention of green energy loss: Estimation of fire hazard potential in wind turbines [J].
Sun, Wei ;
Lin, Wei-Cheng ;
You, Fei ;
Shu, Chi-Min ;
Qin, Sheng-Hui .
RENEWABLE ENERGY, 2019, 140 :62-69
[30]  
Teitge D., 2020, P AIAA 2020 3887 SES, DOI [10.2514/6.2020-3887, DOI 10.2514/6.2020-3887]