Comparative biomechanical analysis of rigid vs. flexible fixation devices for the lumbar spine: A geometrically patient-specific poroelastic finite element study

被引:16
作者
Khalaf, Kinda [1 ,2 ]
Nikkhoo, Mohammad [3 ]
机构
[1] Khalifa Univ Sci & Technol, Dept Biomed Engn, POB 127788, Abu Dhabi, U Arab Emirates
[2] Hlth Engn Innovat Ctr, POB 127788, Abu Dhabi, U Arab Emirates
[3] Islamic Azad Univ, Dept Biomed Engn, Sci & Res Branch, Tehran, Iran
关键词
Poroelastic modeling; Finite element analysis; Patient-specific; Lumbar fixation device; Dynamic rod; Interspinous process devices; INTERBODY FUSION; MOTION SEGMENT; INTERVERTEBRAL DISCS; INTRADISCAL PRESSURE; LOAD-BEARING; ADJACENT; MODEL; STABILIZATION; DEGENERATION; VALIDATION;
D O I
10.1016/j.cmpb.2021.106481
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Lumbar spinal stenosis (LSS), or the narrowing of the spinal canal, continues to be the leading preoperative diagnosis for adults older than 65 years who undergo spine surgery. Although the treatment of LSS depends on its severity, the optimal surgical technique towards decreasing the risk of adjacent segment disease (ASD) remains elusive. This study aimed to comparatively analyze spinal biomechanics with rigid and flexible fixation devices (i.e., rigid and dynamic posterolateral fusion (PLF) and interspinous process (ISP) devices) during daily activities. Methods: Using a validated parametric poroelastic finite element modeling approach, 8 subject-specific pre-operative models were developed, and their validity was evaluated. Parametric FE models of the lumbar spines were then regenerated based on post-operation images for (A) rigid PLF (B) dynamic PLF (C) rigid ISP device (Coflex) and (D) flexible ISP device (DIAM) at L4-L5 level. Biomechanical responses for instrumented and adjacent intervertebral discs (IVDs) were analyzed and compared subject to static and cyclic loading. Results: The preoperative models were well comparable with previous works in literature. The postoperative results for the PLF and Coflex rigid systems, demonstrated greater ROM; higher values of stress and strain in the AF region; and increased disc height and fluid loss at the adjacent levels, as compared with the pre-op models and the post-op results of the flexible systems (i.e., dynamic PLF and DIAM). The calculated forces on the facet joint were of smaller magnitude for the ISP devices as compared to the PLF, particularly during extension. Conclusions: This study demonstrates that the dynamic PLF construct and DIAM implants could be effective to maintain the natural poroelastic characteristics of adjacent IVDs, which could be beneficial for enhancing long-term clinical outcomes. FEM provides clinicians with an invaluable patient-specific quantitative tool for informed surgical planning and discerning follow-up management. (c) 2021 Published by Elsevier B.V.
引用
收藏
页数:12
相关论文
共 61 条
[31]   Biomechanical Investigation Between Rigid and Semirigid Posterolateral Fixation During Daily Activities: Geometrically Parametric Poroelastic Finite Element Analyses [J].
Nikkhoo, Mohammad ;
Lu, Meng-Ling ;
Chen, Wen-Chien ;
Fu, Chen-Ju ;
Niu, Chi-Chien ;
Lin, Yang-Hua ;
Cheng, Chih-Hsiu .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
[32]   Development of a novel geometrically-parametric patient-specific finite element model to investigate the effects of the lumbar lordosis angle on fusion surgery [J].
Nikkhoo, Mohammad ;
Khoz, Zahra ;
Cheng, Chih-Hsiu ;
Niu, Chi-Chien ;
El-Rich, Marwan ;
Khalaf, Kinda .
JOURNAL OF BIOMECHANICS, 2020, 102
[33]   Development and validation of a geometrically personalized finite element model of the lower ligamentous cervical spine for clinical applications [J].
Nikkhoo, Mohammad ;
Cheng, Chih-Hsiu ;
Wang, Jaw-Lin ;
Khoz, Zahra ;
El-Rich, Marwan ;
Hebela, Nader ;
Khalaf, Kinda .
COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 109 :22-32
[34]   Effect of degeneration on fluid-solid interaction within intervertebral disk under cyclic loading - a meta-model analysis of finite element simulations [J].
Nikkhoo, Mohammad ;
Khalaf, Kinda ;
Kuo, Ya-Wen ;
Hsu, Yu-Chun ;
Haghpanahi, Mohammad ;
Parnianpour, Mohamad ;
Wang, Jaw-Lin .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2015, 3
[35]   DYNAMIC RESPONSES OF INTERVERTEBRAL DISC DURING STATIC CREEP AND DYNAMIC CYCLIC LOADING: A PARAMETRIC POROELASTIC FINITE ELEMENT ANALYSIS [J].
Nikkhoo, Mohammad ;
Haghpanahi, Mohammad ;
Parnianpour, Mohamad ;
Wang, Jaw-Lin .
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (01)
[36]   Dynamic stabilization in the surgical management of painful lumbar spinal disorders [J].
Nockels, RP .
SPINE, 2005, 30 (16) :S68-S72
[37]   Pre-tension effects from tightening the ligature on spinous process fracture risk in interspinous process device implantation [J].
Park, Won Man ;
Choi, Dae Kyung ;
Kim, Yoon Hyuk ;
Kim, Kyungsoo .
INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (12) :2597-2604
[38]   Effects of degenerated intervertebral discs on intersegmental rotations, intradiscal pressures, and facet joint forces of the whole lumbar spine [J].
Park, Won Man ;
Kim, Kyungsoo ;
Kim, Yoon Hyuk .
COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (09) :1234-1240
[39]   3-DIMENSIONAL X-RAY-ANALYSIS OF NORMAL MOVEMENT IN THE LUMBAR SPINE [J].
PEARCY, M ;
PORTEK, I ;
SHEPHERD, J .
SPINE, 1984, 9 (03) :294-297
[40]   AXIAL ROTATION AND LATERAL BENDING IN THE NORMAL LUMBAR SPINE MEASURED BY 3-DIMENSIONAL RADIOGRAPHY [J].
PEARCY, MJ ;
TIBREWAL, SB .
SPINE, 1984, 9 (06) :582-587