Reference systems for oxygen sensors in molten 44.5% lead-55.5% bismuth alloy

被引:0
作者
Verdaguer, A. [1 ]
Colominas, S. [1 ]
Victori, L. [1 ]
Abella, J. [1 ]
机构
[1] Univ Ramon Llull, ETS Inst Quim Sarria, Dept Analyt Chem, Elect Methods Lab, Barcelona 08017, Spain
关键词
oxygen sensor; molten metals; lead; bismuth; reference electrode;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Reference systems for potentiometric oxygen sensor in molten 44.5% lead - 55.5% bismuth alloy have been evaluated. Two types of reference systems have been considered: metal / metal oxide and gas with a defined oxygen partial pressure. In/In2O3 and Sn/SnO have been chosen as a metal / metal oxide reference system, and Pt/air is the gas reference system tested. The sensor performance using all three reference systems has been Ar + 10% K or 99.999% Ar) and air (20% O-2). All the tests have been performed in stagnant conditions at 500 degrees C in an autoclave.
引用
收藏
页码:429 / 433
页数:5
相关论文
共 10 条
[1]  
Barin I., 1989, Thermochemical Data of Pure Substances
[2]  
COLOMINAS S, 2004, J NUCL MATER, V260, P335
[3]  
COUROURAU JL, 2004, J NUCL MATER, V254, P335
[4]   NON-ISOTHERMAL PROBE FOR CONTINUOUS MEASUREMENT OF OXYGEN IN STEEL [J].
ETSELL, TH ;
ALCOCK, CB .
SOLID STATE IONICS, 1981, 3-4 (AUG) :621-626
[5]  
FERNANDEZ J, 2002, J NUCL MATER, V47, P301
[6]  
KONYS J, 2001, J NUCL MATER, V289, P296
[7]   ACTIVITY-COEFFICIENT OF OXYGEN IN COPPER-SULFUR MELTS [J].
OTSUKA, S ;
CHANG, YA .
METALLURGICAL TRANSACTIONS B-PROCESS METALLURGY, 1984, 15 (02) :337-344
[8]  
PARKINSON B, 1996, J AM CHEM SOC, V118, P933
[9]  
SEILD A, 1994, J ELECTROCHEM SOC, V141, P2564
[10]  
SEILD A, 1997, J ELECTROCHEM SOC, V144, P3243