High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics

被引:195
作者
Bourier, Felix [1 ,2 ]
Duchateau, Josselin [1 ,2 ]
Vlachos, Konstantinos [1 ,2 ]
Lam, Anna [1 ,2 ]
Martin, Claire A. [1 ,2 ]
Takigawa, Masateru [1 ,2 ]
Kitamura, Takeshi [1 ,2 ]
Frontera, Antonio [1 ,2 ]
Cheniti, Ghassen [1 ,2 ]
Pambrun, Thomas [1 ,2 ]
Klotz, Nicolas [1 ,2 ]
Denis, Arnaud [1 ,2 ]
Derval, Nicolas [1 ,2 ]
Cochet, Hubert [1 ,2 ]
Sacher, Frederic [1 ,2 ]
Hocini, Meleze [1 ,2 ]
Haissaguerre, Michel [1 ,2 ]
Jais, Pierre [1 ,2 ]
机构
[1] Fdn Bordeaux Univ, Electrophysiol & Heart Modeling Inst, IHU Liryc, Pessac, France
[2] Bordeaux Univ Hosp CHU, Electrophysiol & Ablat Unit, Ave Magellan 1, F-33600 Pessac, France
关键词
catheter ablation; computer model; contact force; high-power short-duration; radiofrequency; PULMONARY VEIN ISOLATION; CONTACT-FORCE; ATRIAL-FIBRILLATION; STEAM POP; CATHETER; RECONNECTION; TEMPERATURE; TECHNOLOGY; ELECTRODE; SIZE;
D O I
10.1111/jce.13724
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Radiofrequency (RF) lesion metrics are influenced by underlying parameters like RF power, duration, and contact force (CF), and utilization of lesion metric indices (ablation index [AI]) is a proposed strategy to predict lesion quality. The aim of this study was to analyze the influence of underlying parameters on lesion metrics of high-power short-duration (HPSD) and standard RF applications using an in silico and ex vivo model. Methods and Results Conclusion An in silico simulation study was designed to simulate HPSD and standard ablations, in which ablation parameters could systematically be varied. For each simulated ablation process (n = 5732), the corresponding AI value was calculated. HPSD and standard RF settings were then applied in a porcine ex vivo model (n = 120 lesions). The resulting lesion metrics were compared and analyzed regarding underlying parameters. RF applications of 50 W/13 seconds, 60 W/10 seconds, 70 W/7 seconds, and 80 W/6 seconds resulted in lesion volumes not significantly different from standard RF applications (30 W/30 seconds, P > 0.05). HPSD lesion diameters were significantly larger and lesion depths were significantly smaller (P < 0.01) when compared with standard settings. Prolonging RF duration from 5 to 10 seconds resulted in a +27.5% increase, whereas a prolongation of RF duration from 35 to 40 seconds resulted in a +4.8% increase of AI value only. An increase of CF from 1 to 10 g resulted in a +73.0%, an increase of CF from 20 to 30 g resulted in a +10.1% increase of AI value. HPSD RF applications resulted in similar lesion volumes but significantly different lesion geometries when compared with standard setting RF applications.
引用
收藏
页码:1570 / 1575
页数:6
相关论文
共 19 条
[1]   Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysis [J].
Afzal, Muhammad R. ;
Chatta, Jawaria ;
Samanta, Anweshan ;
Waheed, Salman ;
Mahmoudi, Morteza ;
Vukas, Rachel ;
Gunda, Sampath ;
Reddy, Madhu ;
Dawn, Buddhadeb ;
Lakkireddy, Dhanunjaya .
HEART RHYTHM, 2015, 12 (09) :1990-1996
[2]   Five seconds of 50-60 W radio frequency atrial ablations were transmural and safe: an in vitro mechanistic assessment and force-controlled in vivo validation [J].
Bhaskaran, Abhishek ;
Chik, William ;
Pouliopoulos, Jim ;
Nalliah, Chrishan ;
Qian, Pierre ;
Barry, Tony ;
Nadri, Fazlur ;
Samanta, Rahul ;
Tran, Ying ;
Thomas, Stuart ;
Kovoor, Pramesh ;
Thiagalingam, Aravinda .
EUROPACE, 2017, 19 (05) :874-880
[3]   Fiberoptic Contact-Force Sensing Electrophysiological Catheters: How Precise Is the Technology? [J].
Bourier, Felix ;
Gianni, Carola ;
Dare, Matthew ;
Deisenhofer, Isabel ;
Hessling, Gabriele ;
Reents, Tilko ;
Mohanty, Sanghamitra ;
Trivedi, Chintan ;
Natale, Andrea ;
Al-Ahmad, Amin .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (01) :109-114
[4]   The architecture of the left lateral atrial wall: a particular anatomic region with implications for ablation of atrial fibrillation [J].
Cabrera, Jose Angel ;
Ho, Siew Yen ;
Climent, Vicente ;
Sanchez-Quintana, Damian .
EUROPEAN HEART JOURNAL, 2008, 29 (03) :356-362
[5]  
Calzolari Vittorio, 2017, JACC Clin Electrophysiol, V3, P1126, DOI 10.1016/j.jacep.2017.08.016
[6]   Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values [J].
Das, Moloy ;
Loveday, Jonathan J. ;
Wynn, Gareth J. ;
Gomes, Sean ;
Saeed, Yawer ;
Bonnett, Laura J. ;
Waktare, Johan E. P. ;
Todd, Derick M. ;
Hall, Mark C. S. ;
Snowdon, Richard L. ;
Modi, Simon ;
Gupta, Dhiraj .
EUROPACE, 2017, 19 (05) :775-783
[7]  
HAINES D E, 1991, Journal of Cardiovascular Electrophysiology, V2, P509, DOI 10.1111/j.1540-8167.1991.tb01353.x
[8]   Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size [J].
Ikeda, Atsushi ;
Nakagawa, Hiroshi ;
Lambert, Hendrik ;
Shah, Dipen C. ;
Fonck, Edouard ;
Yulzari, Aude ;
Sharma, Tushar ;
Pitha, Jan V. ;
Lazzara, Ralph ;
Jackman, Warren M. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) :1174-1180
[9]   High-Power and Short-Duration Ablation for Pulmonary Vein Isolation Biophysical Characterization [J].
Leshem, Eran ;
Zilberman, Israel ;
Tschabrunn, Cory M. ;
Barkagan, Michael ;
Contreras-Valdes, Fernando M. ;
Govari, Assaf ;
Anter, Elad .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (04) :467-479
[10]   Real-Time Contact Force Sensing for Pulmonary Vein Isolation in the Setting of Paroxysmal Atrial Fibrillation: Procedural and 1-Year Results [J].
Marijon, Eloi ;
Fazaa, Samia ;
Narayanan, Kumar ;
Guy-Moyat, Benoit ;
Bouzeman, Abdeslam ;
Providencia, Rui ;
Treguer, Frederic ;
Combes, Nicolas ;
Bortone, Agustin ;
Boveda, Serge ;
Combes, Stephane ;
Albenque, Jean-paul .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (02) :130-137