Development of specifications for an integrated piezoelectric wafer active sensors system

被引:1
作者
Jenkins, C [1 ]
Giurgiutiu, V [1 ]
Lin, B [1 ]
Liu, WP [1 ]
机构
[1] Univ S Carolina, Dept Mech Engn, Columbia, SC 29208 USA
来源
Smart Structures and Materials 2005: Smart Structures and Integrated Systems | 2005年 / 5764卷
关键词
structural health monitoring; piezoelectric wafer active sensor; envelope extraction; nondestructive evaluation; piezoelectric; damage detection; cracks; ultrasonic; Lamb waves; SHM; PWAS; NDE;
D O I
10.1117/12.599877
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes work performed in the development of a set of specification for the construction of an integrated electronic system for piezoelectric wafer active sensor (PWAS). The paper starts with a comprehensive review of the PWAS material properties, dimensions, and electrical characteristics. PWAS of various shapes and sizes are considered. Two boundary conditions were examined: free PWAS and PWAS attached to actual structures. For both, the PWAS immittance and the allowable dc and ac voltages were considered. The predicted values were compared with measurements performed over a wide frequency range (10 kHz to 2 MHz). Next, the electronic-equipment specifications were considered. The PWAS can be used in a number of different ways to actively detect damage in structures. Our aim was to develop electronic-equipment specifications that would extract the optimum performance from the PWAS, i.e., maximize the coupling with the structure and obtain large-amplitude Lamb wave transmission and reception. Analytical predictions were compared with measurements made using current laboratory equipment. The comparative analysis revealed that the current electronic equipment does not fully exploit the PWAS capabilities. Hence, the PWAS equipment specifications were divided into two categories: "existing" and "desired". The former category designates integrated electronic equipment that would offer the same PWAS performance as the existing lab equipment, but be of a lower volume/weight/cost. The latter category refers to advanced electronic equipment that will exploit the full potential of PWAS transducers while being of lower volume/weight/cost than the lab equipment. Both categories are presented and discussed in the paper.
引用
收藏
页码:509 / 521
页数:13
相关论文
共 6 条
[1]  
Crawley E. F., 1990, Journal of Intelligent Material Systems and Structures, V1, P4, DOI 10.1177/1045389X9000100102
[2]   The potential of guided waves for monitoring large areas of metallic aircraft fuselage structure [J].
Dalton, RP ;
Cawley, P ;
Lowe, MJS .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2001, 20 (01) :29-46
[3]  
DEUTSCH WAK, 1999, IEEE T ULTRASONICS F, V46
[4]  
Giurgiutiu V, 2000, J INTEL MAT SYST STR, V11, P959, DOI [10.1106/AlHU-23JD-M5AU-ENGW, 10.1106/A1HU-23JD-M5AU-ENGW]
[5]   Active sensors for health monitoring of aging aerospace structures [J].
Giurgiutiu, V ;
Redmond, J ;
Roach, D ;
Rackow, K .
SMART STRUCTURES AND MATERIAL 2000: SMART STRUCTURES AND INTEGRATED SYSTEMS, 2000, 3985 :294-305
[6]   Modelling the input-output behaviour of piezoelectric structural health monitoring systems for composite plates [J].
Liu, TR ;
Veidt, M ;
Kitipornchai, S .
SMART MATERIALS & STRUCTURES, 2003, 12 (05) :836-844