Challenges encountered during closure of patent ductus arteriosus

被引:54
|
作者
Ewert, P [1 ]
机构
[1] German Heart Inst, Dept Congenital Heart Dis, D-13353 Berlin, Germany
关键词
congenital heart disease; persistent ductus arteriosus; transcatheter closure;
D O I
10.1007/s00246-005-1010-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure of patent ductus arteriosus ( PDA) was one of the first interventions established in invasive cardiology and is now more than 30 years old. The challenges for successful closure with the first devices in children consisted of handling the rather large introducer sheaths and stiff application systems. Today, interventional closure can be performed with different types of plugs, occluders, and coils. Thus, beyond infancy, transcatheter closure can be successfully performed in almost all cases. Challenging from the technical standpoint can be the closure of window-type ducts, in which excessive protrusion of the device into the descending aorta should be avoided, as well as the closure of tubular ducts, in which secure anchoring of one or more devices in the vessel can be very difficult. For the combination of a coarctation and an open duct, different strategies can be considered. In selected cases, use of a covered stent can be helpful. From the physiological standpoint, open ducts in patients with pulmonary hypertension with or without concomitant congenital heart diseases can be challenging because testing of vasoreactivity with temporarily blocked duct and the option of subsequent treatment with vasodilators may be necessary prior to making the decision whether the patient may benefit from definitive duct occlusion or not. Large ducts in infants less than 8 kg can be difficult to treat due to a relative mismatch of introducers, plugs, or occluders to the small anatomic dimensions. The implantation of multiple coils can be associated witha higher risk of device embolization. Unfortunately, for the large group of preterm infants with very low body weights and large ducts of tubular shape there is currently no standardized interventional therapy available.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 50 条
  • [21] Percutaneous closure of patent ductus arteriosus with the Nit-Occlud® patent ductus arteriosus device in 268 consecutive cases
    Maksymenko, Andrii, V
    Kuzmenko, Yulia L.
    Dovhaliuk, Arkadii A.
    Motrechko, Oleksandra O.
    Herrmann, Florian E.
    Haas, Nikolaus A.
    Lehner, Anja
    ANNALS OF PEDIATRIC CARDIOLOGY, 2019, 12 (03) : 206 - 211
  • [22] Patent ductus arteriosus closure using an Amplatzer™ ventricular septal defect closure device
    Fernando, Rajeev
    Koranne, Ketan
    Loyalka, Pranav
    Kar, Biswajit
    Gregoric, Igor
    EXPERIMENTAL & CLINICAL CARDIOLOGY, 2013, 18 (01): : E50 - E54
  • [23] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Yasuhara, Jun
    Kuno, Toshiki
    Kumamoto, Takashi
    Kojima, Takuro
    Shimizu, Hiroyuki
    Yoshiba, Shigeki
    Kobayashi, Toshiki
    Sumitomo, Naokata
    HEART AND VESSELS, 2020, 35 (11) : 1605 - 1613
  • [24] Clinical Outcomes After Percutaneous Patent Ductus Arteriosus Closure in Adults
    Wilson, William M.
    Shah, Ashish
    Osten, Mark D.
    Benson, Lee N.
    Abraha, Natalie
    Breitner, Daniel
    Horlick, Eric M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2020, 36 (06) : 837 - 843
  • [25] Percutaneous Patent Ductus Arteriosus (PDA) Closure During Infancy: A Meta-analysis
    Backes, Carl H.
    Rivera, Brian K.
    Bridge, Jeffrey A.
    Armstrong, Aimee K.
    Boe, Brian A.
    Berman, Darren P.
    Fick, Tyler
    Holzer, Ralf J.
    Hijazi, Ziyad M.
    Abadir, Sylvia
    Justino, Henri
    Bergersen, Lisa
    Smith, Charles V.
    Kirpalani, Haresh
    PEDIATRICS, 2017, 139 (02)
  • [26] Transcatheter Closure of the Patent Ductus Arteriosus: An Intention to Treat Analysis
    Sheridan, Bennett J.
    Ward, Cameron J.
    Anderson, Benjamin W.
    Justo, Robert N.
    HEART LUNG AND CIRCULATION, 2013, 22 (06) : 428 - 432
  • [27] Transcatheter Closure of Patent Ductus Arteriosus via Different Approaches
    Zhou, Zeming
    Gu, Yuanrui
    Zheng, Hong
    Li, Shiguo
    Xu, Liang
    Liu, Qiong
    Wan, Junyi
    Lv, Jianhua
    Song, Huijun
    Yan, Chaowu
    Hu, Haibo
    Zhang, Gejun
    Xu, Zhongying
    Jin, Jinglin
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [28] Thrombocytopenia associated with transcatheter closure of giant patent ductus arteriosus
    Liu, Lei
    Yue, Peng
    Zheng, Xiaolan
    Liao, Hongyu
    Li, Jiawen
    Hua, Yimin
    Li, Yifei
    Zhou, Kaiyu
    CARDIOLOGY IN THE YOUNG, 2020, 30 (12) : 1896 - 1901
  • [29] Intravascular Ultrasound during transcatheter coil closure of patent ductus arteriosus: Comparison with angiography
    Hijazi, ZM
    Ahmad, WH
    Geggel, RL
    Marx, GR
    JOURNAL OF INVASIVE CARDIOLOGY, 1998, 10 (05) : 251 - 254
  • [30] Percutaneous closure of the patent ductus arteriosus with Gianturco-coils
    Gildein, HP
    Germeroth, O
    Lilje, C
    Krüger, M
    Wildberg, A
    Mocellin, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 1999, 88 (07): : 514 - 520