Experimental mechanical testing of Poly (L-Lactide) (PLLA) to facilitate pre-degradation characteristics for application in cardiovascular stenting

被引:33
作者
Bobel, Anna C. [1 ]
Lohfeld, Stefan [1 ]
Shirazi, Reyhaneh Neghabat [1 ]
McHugh, Peter E. [1 ]
机构
[1] NUI Galway, Biomech Res Ctr BMEC, Biomed Engn, Coll Engn & Informat, Galway, Ireland
关键词
Biodegradable polymer; Poly (L-Lactide) (PLLA); Mechanical testing; BIODEGRADABLE POLYMERS; POLY(L-LACTIDE); ABSORB; SYSTEM;
D O I
10.1016/j.polymertesting.2016.07.011
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Next-generation stents made from Biodegradable Polymers (BPs) aim to address the long-term risks (i.e. late restenosis and in-stent thrombosis) associated with both Bare Metal Stents and Drug Eluting Stents, whilst aiming to reduce the healthcare costs associated with secondary care. However, the true potential of BPs for cardiovascular load bearing applications does not appear to be fully realised. While the literature provides data on stiffness and strength of BPs, it is lacking pre-degradation experimental data on the recovery behaviour and temperature and strain rate dependency. In this paper, an experimental study is undertaken to address this knowledge gap using Poly (L-Lactide) (PLLA) samples, subjected to tensile testing. Stress-strain characteristics, recovery, relaxation and creep data at body temperature are reported and considered in the context of real-life stent deployment. The experimental data herein reveal a strong temperature and strain rate dependency, whilst demonstrating associated plasticity within the material. The work provides a physical evaluation of PLLA's pre-degradation behaviour, establishing key data points to allow the assessment of PLLA as a viable material in the wider context of stent deployment and load carrying capacity. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 30 条
  • [1] Serial Multimodality Imaging and 2-Year Clinical Outcomes of the Novel DESolve Novolimus-Eluting Bioresorbable Coronary Scaffold System for the Treatment of Single De Novo Coronary Lesions
    Abizaid, Alexandre
    Costa, Ricardo A.
    Schofer, Joachim
    Ormiston, John
    Maeng, Michael
    Witzenbichler, Bernhard
    Botelho, Roberto V.
    Ribamar Costa, J., Jr.
    Chamie, Daniel
    Abizaid, Andrea S.
    Castro, Juliana P.
    Morrison, Lynn
    Toyloy, Sara
    Bhat, Vinayak
    Yan, John
    Verheye, Stefan
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (06) : 565 - 574
  • [2] Agrawal C M, 1995, Tissue Eng, V1, P241, DOI 10.1089/ten.1995.1.241
  • [3] Orthopaedic applications for PLA-PGA biodegradable polymers
    Athanasiou, KA
    Agrawal, CM
    Barber, FA
    Burkhart, SS
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) : 726 - 737
  • [4] Computational Bench Testing to Evaluate the Short-Term Mechanical Performance of a Polymeric Stent
    Bobel, A. C.
    Petisco, S.
    Sarasua, J. R.
    Wang, W.
    McHugh, P. E.
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2015, 6 (04) : 519 - 532
  • [5] Chowdhury A.W., 2014, CARDIOVASC J, V6, P90
  • [6] Poly(trimethylene terephthalate) molecular weight and Mark-Houwink equation
    Chuah, HH
    Lin-Vien, D
    Soni, U
    [J]. POLYMER, 2001, 42 (16) : 7137 - 7139
  • [7] A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent
    Debusschere, Nic
    Segers, Patrick
    Dubruel, Peter
    Verhegghe, Benedict
    De Beule, Matthieu
    [J]. JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2012 - 2018
  • [8] Eswaran S.K., MAT MODELING POLYLAC
  • [9] Absorbable stent: focus on clinical applications and benefits
    Gonzalo, Nieves
    Macaya, Carlos
    [J]. VASCULAR HEALTH AND RISK MANAGEMENT, 2012, 8 : 125 - 132
  • [10] Mechanical properties of laser cut poly(L-lactide) micro-specimens: Implications for stent design, manufacture, and sterilization
    Grabow, N
    Schlun, M
    Sternberg, K
    Hakansson, N
    Kramer, S
    Schmitz, KP
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 25 - 31