Reliability of measured tidal volume in mechanically ventilated young pigs with normal lungs

被引:14
|
作者
Heulitt, MJ
Holt, SJ
Thurman, TL
Hall, RA
Jo, CH
Simpson, P
机构
[1] Arkansas Childrens Hosp, Little Rock, AR 72202 USA
[2] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Sect Crit Care Med, Little Rock, AR 72205 USA
[3] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Biostat Sect, Little Rock, AR 72205 USA
关键词
respiratory physiology; mechanical ventilation; lung volume measurements; reproducibility of results;
D O I
10.1007/s00134-005-2717-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: This study examined whether volumes can be accurately measured at the expiratory valve of a conventional ventilator using pressure support ventilation and positive end expiratory pressure with software compensation for circuit compliance available in the Servo i ventilator. Design and setting: Comparison of two methods for measuring tidal volume in an animal laboratory. Subjects: Twenty healthy, intubated, sedated, spontaneously breathing pigs. Interventions: Volume was measured in ten neonatal-sized and ten pediatric-sized pigs ventilated with the Servo i' ventilator using pressure support ventilation and positive end expiratory pressure with and without circuit compliance compensation. We compared volume measured at the airway opening by pneumotachography to volume measured at the expiratory valve of a conventional ventilator. Measurements and results: The use of circuit compliance compensation significantly improved the agreement between the two volume methods in neonatal-sized piglets (concordance correlation coefficient: with circuit compliance compensation, 0.97; without, 0.87, p=0.002). In pediatric-sized pigs there was improvement in agreement between the two measurement methods due to circuit compliance compensation (concordance correlation coefficient with circuit compliance compensation, 0.97; without, 0.88, p=0.027). With circuit compliance compensation off there was positive bias: mean difference (bias) 2.97 +/- 0.12 in neonatal-sized and 3.75 +/- 0.38 in pediatric-sized pigs. Conclusions: Our results show that volume can be accurately measured at the expiratory valve of a conventional ventilator in neonatal- and pediatric-sized animals.
引用
收藏
页码:1255 / 1261
页数:7
相关论文
共 25 条
  • [21] Low tidal volume ventilation ameliorates left ventricular dysfunction in mechanically ventilated rats following LPS-induced lung injury
    Cherpanath, Thomas G. V.
    Smeding, Lonneke
    Hirsch, Alexander
    Lagrand, Wim K.
    Schultz, Marcus J.
    Groeneveld, A. B. Johan
    BMC ANESTHESIOLOGY, 2015, 15
  • [22] Effects of positive end-expiratory pressure and body position on pulmonary blood flow redistribution in mechanically ventilated normal pigs
    Richard, JC
    Decailliot, F
    Janier, M
    Annat, G
    Guérin, C
    CHEST, 2002, 122 (03) : 998 - 1005
  • [23] Tidal volume selection in volume-controlled ventilation guided by driving pressure versus actual body weight in healthy anesthetized and mechanically ventilated dogs: A randomized crossover trial
    Donati, Pablo A.
    Tarragona, Lisa
    Araos, Joaquin
    Zaccagnini, Andrea C.
    Diaz, Alfredo
    Nigro, Nestor
    Sandez, Ignacio
    Plotnikow, Gustavo
    Staffieri, Francesco
    Otero, Pablo E.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2024, 51 (05) : 408 - 416
  • [24] Serum levels of N–terminal proB–type natriuretic peptide in mechanically ventilated critically ill patients – relation to tidal volume size and development of acute respiratory distress syndrome
    Rogier M Determann
    Annick ANM Royakkers
    Jacqueline Schaefers
    Anita M de Boer
    Jan M Binnekade
    Jan P van Straalen
    Marcus J Schultz
    BMC Pulmonary Medicine, 13
  • [25] Serum levels of N-terminal proB-type natriuretic peptide in mechanically ventilated critically ill patients - relation to tidal volume size and development of acute respiratory distress syndrome
    Determann, Rogier M.
    Royakkers, Annick A. N. M.
    Schaefers, Jacqueline
    de Boer, Anita M.
    Binnekade, Jan M.
    van Straalen, Jan P.
    Schultz, Marcus J.
    BMC PULMONARY MEDICINE, 2013, 13