Detection of gamma ray polarization using a 3D position sensitive CdZnTe detector

被引:0
作者
Xu, D [1 ]
He, Z [1 ]
机构
[1] Univ Michigan, Nucl Engn & Radiol Sci Dept, Ann Arbor, MI 48109 USA
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
When a polarized gamma ray photon undergoes a Compton scattering, the probability to scatter at a fixed scattering angle theta depends on the azimuthal angle phi. The polarization of incident gamma rays can he measured using this effect by observing the angular distribution of scatterings. Room temperature 3-dimensional position sensitive CdZnTe detector can provide good energy resolution as well as positions of interactions, allowing to perform Compton imaging and polarization detection simultaneously. In this paper, we demonstrate that a 11 x 11 pixilated 15 x 15 x 10mm(3) CdZnTe detector with 3D position sensing capability can be an effective instrument to detect the polarization of incident gamma rays.
引用
收藏
页码:376 / 380
页数:5
相关论文
共 50 条
[21]   A modeling method to calibrate the interaction depth in 3-D position sensitive CdZnTe gamma-ray spectrometers [J].
Li, W ;
He, Z ;
Knoll, GF ;
Wehe, DK ;
Du, YF .
1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, :478-482
[22]   Monte Carlo investigation of the charge sharing effects in 3-D position sensitive CdZnTe gamma ray spectrometers [J].
Du, Y.F. ;
He, Z. ;
Li, W. ;
Knoll, G.F. ;
Wehe, D.K. .
IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 :634-637
[23]   Thermal Neutron Source Location Using a 3-D Position-Sensitive CdZnTe Detector Array [J].
Brown, S. T. ;
Boucher, Y. A. ;
Mann, J. ;
Zhu, Y. ;
He, Z. .
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
[24]   A modeling method to calibrate the interaction depth in 3-D position sensitive CdZnTe gamma-ray spectrometers [J].
Li, W ;
He, Z ;
Knoll, GF ;
Wehe, DK ;
Du, YF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :890-894
[25]   A POSITION-SENSITIVE GAMMA-RAY DETECTOR [J].
CHIAVASSA, E ;
DELLACASA, G ;
DEMARCO, N ;
FERRERO, F ;
MUSSO, MGA ;
PICCOTTI, A ;
VERCELLIN, E .
NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1989, 101 (05) :805-814
[26]   Monte Carlo investigation of the charge sharing effects in 3-D position sensitive CdZnTe gamma ray spectrometers [J].
Univ of Michigan, Ann Arbor, United States .
IEEE Trans Nucl Sci, 4 I (844-847)
[27]   Sensitivity of Gamma-Ray Source Detection Using 3D-Position-Sensitive Semiconductor Detectors [J].
Wahl, Christopher G. ;
He, Zhong .
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, :2609-2613
[28]   Development of a gamma ray monitor using a CdZnTe semiconductor detector [J].
Rasolonjatovo, AHD ;
Shiomi, T ;
Nakamura, T ;
Nishizawa, H ;
Tsudaka, Y ;
Fujiwara, H ;
Araki, H ;
Matsuo, K .
RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) :77-80
[29]   Development of a gamma ray monitor using a CdZnTe semiconductor detector [J].
Rasolonjatovo, AHD ;
Shiomi, T ;
Nakamura, T ;
Nishizawa, H ;
Tsudaka, Y ;
Fujiwara, H ;
Araki, H ;
Matsuo, K .
SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, :A77-A80
[30]   Efficient temperature corrections for gamma-ray energy reconstruction in 3-D position-sensitive CdZnTe detectors [J].
Xia, Jiawei ;
Zhu, Yuefeng ;
He, Zhong .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954