Functional assessment of the left atrium by real-time three-dimensional echocardiography using a novel dedicated analysis tool: initial validation studies in comparison with computed tomography

被引:54
作者
Rohner, Andreas [1 ]
Brinkert, Miriam [1 ]
Kawel, Nadine [2 ]
Buechel, Ronny R. [1 ]
Leibundgut, Gregor [1 ]
Grize, Leticia [3 ]
Kuehne, Michael [1 ]
Bremerich, Jens [2 ]
Kaufmann, Beat A. [1 ]
Zellweger, Michael J. [1 ]
Buser, Peter [1 ]
Osswald, Stefan [1 ]
Handke, Michael [1 ,4 ]
机构
[1] Univ Basel Hosp, Dept Cardiol, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Radiol, CH-4031 Basel, Switzerland
[3] Univ Basel, Swiss Trop & Publ Hlth Inst, CH-4002 Basel, Switzerland
[4] Cantonal Hosp Liestal, Dept Cardiol, CH-4410 Liestal, Switzerland
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2011年 / 12卷 / 07期
关键词
Three-dimensional echocardiography; Imaging left atrium; Computed tomography; CARDIAC RESYNCHRONIZATION THERAPY; RIGHT-VENTRICULAR VOLUMES; HYPERTROPHIC CARDIOMYOPATHY; QUANTITATIVE-ANALYSIS; 3D ECHOCARDIOGRAPHY; CATHETER ABLATION; ADULT PATIENTS; HEART-FAILURE; SINUS RHYTHM; SIZE;
D O I
10.1093/ejechocard/jer066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims A novel real-time three-dimensional echocardiography (RT3DE) analysis tool specifically designed for evaluation of the left atrium enables comprehensive evaluation of left atrial (LA) size, global, and regional function using a dynamic 16-segment model. The aim of this study was the initial validation of this method using computed tomography (CT) as the method of reference. Methods and results The study population consisted of 34 prospectively enrolled patients with clinical indication for pulmonary vein isolation. A dynamic polyhedron model of the left atrium was generated using RT3DE. LA maximum and minimum volumes (LA(max)/LA(min)) and emptying fraction (LAEF) were determined and compared with the results obtained by CT. High correlations between RT3DE and CT were found for LA(max) (r = 0.92, P < 0.001), LA(min) (r = 0.95, P < 0.001), and LAEF (r = 0.82, P < 0.001). LA(max) and LA(min) were lower by RT3DE than by CT (95.0 +/- 44.7 vs. 119.8 +/- 50.5 mL, P < 0.001 and 58.1 +/- 41.3 vs. 83.3 +/- 52.6 mL, P < 0.001, respectively), whereas LAEF was measured higher by RT3DE (42.8 +/- 15.2 vs. 34.2 +/- 15.4%, P < 0.001, respectively). RT3DE measurements closely correlated in terms of intra-observer (intra-class correlation r = 0.99, r = 0.99, r = 0.96, respectively) and interobserver variability (r = 0.97, r = 0.98, r = 0.88, respectively). Conclusions LA volumes and EF as assessed by RT3DE correlate highly with CT measurements, albeit there is some bias between the imaging modalities. Most importantly, RT3DE measurements using the novel dedicated LA analysis tool are robust in terms of observer variability and thus suitable for follow-up analyses.
引用
收藏
页码:497 / 505
页数:9
相关论文
共 45 条
[1]   Assessment of left atrial volume and function by real-time three-dimensional echocardiography [J].
Anwar, Ashraf M. ;
Soliman, Osama I. I. ;
Geleijnse, Marcel L. ;
Nemes, Attila ;
Vletter, Wim B. ;
ten Cate, Folkert J. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 123 (02) :155-161
[2]   Assessment of left atrial ejection force in hypertrophic cardiomyopathy using real-time three-dimensional echocardiography [J].
Anwar, Ashraf M. ;
Soliman, Osama I. I. ;
Geleijnse, Marcel L. ;
Michels, Michelle ;
Vletter, Wim B. ;
Nemes, Attila ;
ten Cate, Folkert J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (06) :744-748
[3]   Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging [J].
Artang, Ramin ;
Migrino, Raymond Q. ;
Harmann, Leanne ;
Bowers, Mark ;
Woods, Timothy D. .
CARDIOVASCULAR ULTRASOUND, 2009, 7
[4]   Normal reference ranges for left and right atrial volume indexes and ejection fractions obtained with real-time three-dimensional echocardiography [J].
Aune, Erlend ;
Baekkevar, Morten ;
Roislien, Jo ;
Rodevand, Olaf ;
Otterstad, Jan Erik .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (06) :738-744
[5]   Left Atrial Volume and Geometry in Healthy Aging The Cardiovascular Health Study [J].
Aurigemma, Gerard P. ;
Gottdiener, John S. ;
Arnold, Alice M. ;
Chinali, Marcello ;
Hill, Jeffrey C. ;
Kitzman, Dalane .
CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (04) :282-289
[6]   Comparison of the Accuracy of Multidetector Computed Tomography Versus Two-Dimensional Echocardiography to Measure Left Atrial Volume [J].
Avelar, Erick ;
Durst, Ronen ;
Rosito, Guido A. ;
Thangaroopan, Molly ;
Kumar, Simi ;
Tournoux, Francois ;
Chan, Raymond C. ;
Hung, Judy ;
Hoffmann, Udo ;
Abbara, Suhny ;
Brady, Thomas ;
Cury, Ricardo C. .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (01) :104-109
[7]   Three-Dimensional Echocardiographic Assessment of Left Atrial Size and Function and the Normal Range of Asynchrony in Healthy Individuals [J].
Azar, Francisco ;
de Isla, Leopoldo Perez ;
Moreno, Mar ;
Landaeta, Agustin ;
Refoyo, Elena ;
Fernandez, Teresa Loez ;
Macaya, Carlos ;
Zamorano, Jose .
REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (07) :816-819
[8]   Quantitative analysis of left atrial function during left ventricular ischemia with and without left atrial ischemia: A real-time 3-dimensional echocardiographic study [J].
Bauer, F ;
Jones, M ;
Qin, JX ;
Castro, P ;
Asada, J ;
Sitges, M ;
Cardon, LA ;
Tsujino, H ;
Zetts, AD ;
Panza, JA ;
Thomas, JD ;
Shiota, T .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (08) :795-801
[9]   Determinant of left atrial dilation in patients with hypertrophic cardiomyopathy: A real-time 3-dimensional echocardiographic study [J].
Bauer, F ;
Shiota, T ;
White, RD ;
Lever, HM ;
Qin, JX ;
Drinko, J ;
Martin, M ;
Tsujino, H ;
Sitges, M ;
Kim, YJ ;
Thomas, JD .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (09) :968-975
[10]   LEFT ATRIAL SIZE AND THE RISK OF STROKE AND DEATH - THE FRAMINGHAM HEART-STUDY [J].
BENJAMIN, EJ ;
DAGOSTINO, RB ;
BELANGER, AJ ;
WOLF, PA ;
LEVY, D .
CIRCULATION, 1995, 92 (04) :835-841