New Grafted Nanosilica-Based Sorbent for Needle Trap Extraction of Polycyclic Aromatic Hydrocarbons from Water Samples Followed by GC/MS

被引:20
作者
Bagheri, Habib [1 ]
Roostaie, Ali [1 ]
Babanezhad, Esmaeil [1 ]
机构
[1] Sharif Univ Technol, Dept Chem, Environm & Bioanalyt Labs, Tehran, Iran
关键词
Gas chromatography/Mass spectrometry; Needle trap extraction; Modified nanosilica; cis-9-Octadecenoic acid; Polycyclic aromatic hydrocarbons; CHROMATOGRAPHY-MASS SPECTROMETRY; SOLID-PHASE MICROEXTRACTION; VOLATILE ORGANIC-COMPOUNDS; GAS-CHROMATOGRAPHY; SILICA; PRECONCENTRATION; DEGRADATION; POLYMER; DEVICES; ONLINE;
D O I
10.1007/s10337-011-2094-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the preparation of a new grafted nanosilica-based sorbent was extensively investigated. An inexpensive modifier, cis-9-octadecenoic acid (oleic acid) was selected to be grafted on the surface of the nanosilica particles as the support. The grafting process was accurately confirmed by Fourier transform infra-red spectrometry (FT-IR). Applicability of the prepared sorbent was thoroughly examined by needle trap extraction (NTE) method. The grafted sorbent was dispersed in the appropriate solvent and carefully packed inside a steel needle. Feasibility of the method was completely examined using polycyclic aromatic hydrocarbons (PAHs), as model compounds. For extraction of analytes from aqueous samples, the prepared needle trap device (NTD) was placed in the headspace of the sample and another needle was also inserted into the sample solution to purge the circulating headspace into the sample. For increasing the extraction efficiency, influencing parameters including extraction time and temperature, flow rate of analyte through the needle trap, the ionic strength, desorption temperature, and time were optimized. The limit of detection (LOD) and relative standard deviation (RSD) values of the method under optimized conditions were 2-5 ng L(-1) and 1.1-4.8%, respectively. The RSD% for fluorene was somewhat higher and a value of 16.8% at 40 ng L(-1) was achieved. Finally the developed method was applied to the analysis of tap water and Zayandeh-roud river samples and the relative recovery (RR %) values were found to be in the range of 77-109%, under the optimized conditions.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 29 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   Sol-gel-based solid-phase microextraction and gas chromatography-mass spectrometry determination of dextromethorphan and dextrorphan in human plasma [J].
Bagheri, H ;
Es-Haghi, A ;
Rouini, MR .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (02) :147-157
[3]   Pyrrole-based conductive polymer as the solid-phase extraction medium for the preconcentration of environmental pollutants in water samples followed by gas chromatography with flame ionization and mass spectrometry detection [J].
Bagheri, H ;
Mohammadi, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :23-30
[4]   A novel needle trap sorbent based on carbon nanotube-sol-gel for microextraction of polycyclic aromatic hydrocarbons from aquatic media [J].
Bagheri, Habib ;
Ayazi, Zahra ;
Aghakhani, Ali .
ANALYTICA CHIMICA ACTA, 2011, 683 (02) :212-220
[5]   An interior needle electropolymerized pyrrole-based coating for headspace solid-phase dynamic extraction [J].
Bagheri, Habib ;
Babanezhad, Esmaeil ;
Khalilian, Faezeh .
ANALYTICA CHIMICA ACTA, 2009, 634 (02) :209-214
[6]  
Berland R.G., 1989, WATER POLLUT RES J C, V24, P179
[7]   Simultaneous sampling and analysis for vapor mercury in ambient air using needle trap coupled with gas chromatography-mass spectrometry [J].
Cai, Jibao ;
Ouyang, Gangfeng ;
Gong, Ying ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (01) :19-24
[8]   Fast and sensitive environmental analysis utilizing microextraction in packed syringe online with gas chromatography-mass spectrometry - Determination of polycyclic aromatic hydrocarbons in water [J].
El-Beqqali, Aziza ;
Kussak, Anders ;
Abdel-Rehim, Mohamed .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (02) :234-238
[9]   Immobilization strategies for laccase from Trametes versicolor on mesostructured silica materials and the application to the degradation of naphthalene [J].
Fernando Bautista, L. ;
Morales, Gabriel ;
Sanz, Raquel .
BIORESOURCE TECHNOLOGY, 2010, 101 (22) :8541-8548
[10]   On-column injection system for use of large diameter inside needle capillary adsorption trap devices [J].
Hrivnak, Jan ;
Tolgyessy, Peter ;
Kral'ovicova, Eva .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (23) :4815-4816