Implant Distribution in Surgically Instrumented Lenke 1 Adolescent Idiopathic Scoliosis Does It Affect Curve Correction?

被引:35
作者
Le Naveaux, Franck [1 ,2 ]
Aubin, Carl-Eric [1 ,2 ]
Larson, A. Noelle [3 ]
Polly, David W., Jr. [4 ]
Baghdadi, Yaser M. K. [3 ]
Labelle, Hubert [2 ]
机构
[1] Polytech Montreal, Dept Mech Engn, Montreal, PQ H3C 3A7, Canada
[2] St Justine Univ, Ctr Hosp, Res Ctr, Montreal, PQ, Canada
[3] Mayo Clin, Rochester, MN USA
[4] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55455 USA
基金
加拿大自然科学与工程研究理事会;
关键词
adolescent idiopathic scoliosis; pedicle screw; implant density; implant distribution; implant pattern; curve correction; PEDICLE SCREW FIXATION; SPINAL INSTRUMENTATION; FOLLOW-UP; DENSITY; CONFIGURATIONS; VARIABILITY; DEFORMITIES; PLACEMENT; SURGERY; HOOKS;
D O I
10.1097/BRS.0000000000000793
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Retrospective review of prospective multicenter database of patients with adolescent idiopathic scoliosis who underwent posterior spinal fusion. Objective. To analyze implant distribution in surgically instrumented Lenke 1 patients and evaluate how it impacts curve correction. Summary of Background Data. Although pedicle screw constructs have demonstrated successful surgical results, the optimal pedicle screw density and configuration remain unclear. Methods. A total of 279 patients with adolescent idiopathic scoliosis treated with pedicle screws were reviewed. Implant density was computed for each side of the instrumented segment, which was divided into 5 regions: distal and proximal ends (upper/lower instrumented vertebra + 1 adjacent vertebra), apical region (apex +/- 1 vertebra), and the 2 regions in between (upper/lower periapical). Centralized measurement of Cobb angle and thoracic kyphosis was performed on preoperative and at 1-year postoperative radiographs as well as percent curve flexibility. Results. The mean implant density was 1.66 implants per level fused (1.08 to 2) with greater available pedicles filled on the concavity (92%, 53%-100%) compared with the convex side (73%, 23%-100%, P < 0.01). The concave distal end region had the highest density with 99% of pedicles filled (P < 0.01), followed by the other concave regions and the convex distal end region (88%-94%) (P > 0.05). Other convex regions of the construct had less instrumentation, with only 54% to 78% of pedicles instrumented (P < 0.01). Implant density in the concave apical region (69%, 23%-100%) had a positive effect on curve correction (P = 0.002, R = 0.19). Conclusion. Significant variability exists in implant distribution with the greatest variation on the convex side and lowest implant density used in the periapical convex regions. Only instrumentation at the concave side, particularly at the apical region, was associated with curve correction. This suggests that for a low implant density construct, the best regions for planned screw dropout may be in the periapical convexity.
引用
收藏
页码:462 / 468
页数:7
相关论文
共 35 条
[1]  
ASHER MA, 1995, SPINE, V20, P1386, DOI 10.1097/00007632-199506000-00010
[2]   Variability of spinal instrumentation configurations in adolescent idiopathic scoliosis [J].
Aubin, Carl-Eric ;
Labelle, Hubert ;
Ciolofan, Oana C. .
EUROPEAN SPINE JOURNAL, 2007, 16 (01) :57-64
[3]   Low-density versus high-density thoracic pedicle screw constructs in adolescent idiopathic scoliosis: do more screws lead to a better outcome? [J].
Bharucha, Neil J. ;
Lonner, Baron S. ;
Auerbach, Joshua D. ;
Kean, Kristin E. ;
Trobisch, Per D. .
SPINE JOURNAL, 2013, 13 (04) :375-381
[4]   Surgical treatment of idiopathic adolescent scoliosis [J].
Bridwell, KH .
SPINE, 1999, 24 (24) :2607-2616
[5]   Correction of Lenke 5 Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation Does Implant Density Influence the Correction? [J].
Chen, Jiayu ;
Yang, Changwei ;
Ran, Bo ;
Wang, Yunhua ;
Wang, Chao ;
Zhu, Xiaodong ;
Bai, Yushu ;
Li, Ming .
SPINE, 2013, 38 (15) :E946-E951
[6]   Correlation of Scoliosis Curve Correction With the Number and Type of Fixation Anchors [J].
Clements, David H. ;
Betz, Randal R. ;
Newton, Peter O. ;
Rohmiller, Michael ;
Marks, Michelle C. ;
Bastrom, Tracey .
SPINE, 2009, 34 (20) :2147-2150
[7]   Pedicle screw fixation of the thoracic spine:: An in vitro biomechanical study on different configurations [J].
Deviren, V ;
Acaroglu, E ;
Lee, J ;
Fujita, M ;
Hu, S ;
Lenke, LG ;
Polly, D ;
Kuklo, TR ;
O'Brien, M ;
Brumfield, D ;
Puttlitz, CM .
SPINE, 2005, 30 (22) :2530-2537
[8]   Selective posterior thoracic fusions for adolescent idiopathic scoliosis [J].
Dobbs, Matthew B. ;
Lenke, Lawrence G. ;
Kim, Yongjung J. ;
Kamath, Ganesh ;
Peelle, Michael W. ;
Bridwell, Keith H. .
SPINE, 2006, 31 (20) :2400-2404
[9]   Do Anchor Density or Pedicle Screw Density Correlate With Short-Term Outcome Measures in Adolescent Idiopathic Scoliosis Surgery? [J].
Gebhart, Sandra ;
Alton, Timothy B. ;
Bompadre, Viviana ;
Krengel, Walter F. .
SPINE, 2014, 39 (02) :E104-E110
[10]   Randomized clinical study on surgical techniques with different pedicle screw densities in the treatment of adolescent idiopathic scoliosis types Lenke 1A and 1B [J].
Gotfryd A.O. ;
Avanzi O. .
Spine Deformity, 2013, 1 (4) :272-279