Pulmonary artery catheter monitoring in 2011

被引:38
作者
Richard, Christian [1 ]
Monnet, Xavier
Teboul, Jean-Louis
机构
[1] Hop Bicetre, AP HP, Serv Reanimat Med, F-94270 Le Kremlin Bicetre, France
关键词
cardiac output; pulmonary artery catheter; pulmonary hypertension; right ventricular failure; weaning from mechanical ventilation; RESPIRATORY-DISTRESS-SYNDROME; END-EXPIRATORY PRESSURE; THERMODILUTION CARDIAC-OUTPUT; ACUTE LUNG INJURY; TRANSPULMONARY THERMODILUTION; PULSE CONTOUR; VENTRICULAR FUNCTION; FAILURE; CARE; METAANALYSIS;
D O I
10.1097/MCC.0b013e3283466b85
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Hemodynamic monitoring has gained widespread acceptance in intensive care units. Despite ongoing debate regarding its safety and efficacy, monitoring with the pulmonary artery catheter (PAC) remains used for the management of severe heart failure and shock. Recent findings To reanalyze using the most recently published literature in the field, the role of the PAC to manage critically ill patients with right ventricular failure, pulmonary hypertension and weaning failure from cardiac origin. The role of PAC as a gold standard to validate new cardiac output monitoring devices was also reported. Summary Despite competition with less invasive hemodynamic monitoring devices or ultrasonic methods, the PAC remains a useful monitoring device in situations in which the knowledge of pulmonary artery pressure, pulmonary artery occlusion pressure and oxygenation parameters are needed. The proper use of PAC requires, however, a perfect knowledge of the numerous pitfalls and difficulties in interpretation of its measurements.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 46 条
[31]   Incidence and prognostic value of right ventricular failure in acute respiratory distress syndrome [J].
Osman, David ;
Monnet, Xavier ;
Castelain, Vincent ;
Anguel, Nadia ;
Warszawski, Josiane ;
Teboul, Jean-Louis ;
Richard, Christian .
INTENSIVE CARE MEDICINE, 2009, 35 (01) :69-76
[32]   Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets [J].
Osthaus, Wilhelm Alexander ;
Huber, Dirk ;
Beck, Carsten ;
Winterhalter, Michael ;
Boethig, Dietmar ;
Wessel, Armin ;
Suempelmann, Robert .
PEDIATRIC ANESTHESIA, 2007, 17 (08) :749-755
[33]   Minimally Invasive Measurement of Cardiac Output during Surgery and Critical Care A Meta-analysis of Accuracy and Precision [J].
Peyton, Philip J. ;
Chong, Simon W. .
ANESTHESIOLOGY, 2010, 113 (05) :1220-1235
[34]   Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives [J].
Reuter, Daniel A. ;
Huang, Cecil ;
Edrich, Thomas ;
Shernan, Stanton K. ;
Eltzschig, Holger K. .
ANESTHESIA AND ANALGESIA, 2010, 110 (03) :799-811
[35]  
Rich JD, 2010, CHEST
[36]   LEFT-VENTRICULAR FUNCTION DURING WEANING OF PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
RICHARD, C ;
TEBOUL, JL ;
ARCHAMBAUD, F ;
HEBERT, JL ;
MICHAUT, P ;
AUZEPY, P .
INTENSIVE CARE MEDICINE, 1994, 20 (03) :181-186
[37]   Weaning failure from cardiovascular origin [J].
Richard, C ;
Teboul, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (12) :1605-1607
[38]   Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome - A randomized controlled trial [J].
Richard, C ;
Warszawski, J ;
Anguel, N ;
Deye, N ;
Combes, A ;
Barnoud, D ;
Boulain, T ;
Lefort, Y ;
Fartoukh, M ;
Baud, F ;
Boyer, A ;
Brochard, L ;
Teboul, JL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (20) :2713-2720
[39]   Nitroglycerin can facilitate weaning of difficult-to-wean chronic obstructive pulmonary disease patients: a prospective interventional non-randomized study [J].
Routsi, Christina ;
Stanopoulos, Ioannis ;
Zakynthinos, Epaminondas ;
Politis, Panagiotis ;
Papas, Vassilios ;
Zervakis, Demetrios ;
Zakynthinos, Spyros .
CRITICAL CARE, 2010, 14 (06)
[40]   Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients [J].
Sakka, SG ;
Reinhart, K ;
Meier-Hellmann, A .
INTENSIVE CARE MEDICINE, 1999, 25 (08) :843-846