Method for Evaluation of Trustworthiness of Oscillometric Blood Pressure Measurements

被引:0
作者
Koohi, Iraj [1 ]
Ahmad, Saif [1 ]
Batkin, Izmail [1 ]
Groza, Voicu Z. [1 ]
Shirmohammadi, Shervin [1 ]
Dajani, Hilmi R. [1 ]
Petriu, Emil M. [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON, Canada
来源
2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS | 2015年
关键词
Mean arterial pressure; systolic; diastolic; blood pressure; vessel compliance; oscillometric waveform simulation; PULSE-WAVE VELOCITY; ARTERIAL STIFFNESS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simple, unobtrusive, and reliable estimation of cardiovascular parameters is a challenge. We present a novel, simple, and noninvasive method called Ratio2 that provides expected ranges for systolic and diastolic blood pressure values (SBP, DBP) estimated by any algorithm, and an evaluation of vessel compliance. Ratio2 was developed in the frame of the oscillometric blood pressure estimation and it exploits the equality between the arterial blood pressure and the cuff pressure at the mean arterial pressure (MAP). This method is based on the observation that the brachial arterial blood pressure pulses, with MAP used as baseline, are characterized by a peak to trough ratio close to 2. This ratio is employed to characterize expected ranges for estimates of systolic and diastolic blood pressure. Any SBP or DBP measurement which is not contained in these intervals is deemed untrustworthy, and it is marked as such. Ratio2 also provides parameters that are used in a mathematical model of arterial blood pressure (BP) to evaluate vessel stiffness. We tested the performance of the Ratio2 method on 150 oscillometric recordings and their corresponding Omron BP estimates obtained from 10 healthy subjects. Results are encouraging, whereby, (a) out-of-range values obtained with the maximum amplitude algorithm (MAA) and the maximum/minimum slope algorithm (MMSA) methods were successfully detected, and (b) linear correlation between age and vessel compliance is -85% (p<0.005). Therefore, we conclude that the proposed work shows promise towards providing noninvasive BP monitors with an inbuilt mechanism for assessing the fidelity of their BP estimates along with an indicator of vessel compliance.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [31] A Developed Algorithm for Oscillometric Blood Pressure Measurement
    Chen, Min
    Wang, Qun
    Mei, Zhe
    Liu, Zhiwen
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [32] VibroBP: An Oscillometric Smartphone Blood Pressure App
    Barry, Colin
    Kumamoto, Tatsuo
    Averbuj, Amparo
    Wang, Edward Jay
    COMPANION OF THE 2024 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING, UBICOMP COMPANION 2024, 2024, : 220 - 224
  • [33] Evaluation the Accuracy of Oscillometric Blood Pressure Measurement According to the AAMI SP10
    Xiang, H. Y.
    Liu, Y. Y.
    Guo, T.
    Qin, Y. F.
    Yu, M. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 998 - 1001
  • [34] Blood Pressure Assessed through Oscillometric and Auscultatory Method Before and After Exercise in the Elderly
    de Lima Scher, Luria Melo
    Ferriolli, Eduardo
    Moriguti, Julio C.
    Lima, Nereida K. C.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 94 (05) : 656 - 662
  • [35] VALIDATION OF A NOVEL METHOD FOR NONINVASIVE ESTIMATION OF CARDIAC OUTPUT USING BRACHIAL OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS IN PATIENTS WITH VARIOUS CLINICAL CONDITIONS
    Madrid-Munoz, Camilo
    Alvarez-Montoya, Diego
    Fernandez-Ruiz, Ricardo
    Gallo-Villegas, Jaime
    Aristizabal-Ocampo, Dagnovar
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [36] Oscillometric and auscultatory blood pressure measurement in the assessment of blood pressure and target organ damage
    Johansson, Jouni K.
    Puukka, Pauli J.
    Jula, Antti M.
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 6 - 13
  • [37] Evaluation of a Novel Brachial Cuff-Based Oscillometric Method for Estimating Central Systolic Pressure in Hemodialysis Patients
    Sarafidis, Pantelis A.
    Georgianos, Panagiotis I.
    Karpetas, Antonios
    Bikos, Athanasios
    Korelidou, Linda
    Tersi, Maria
    Divanis, Dimitrios
    Tzanis, Georgios
    Mavromatidis, Konstantinos
    Liakopoulos, Vassilios
    Zebekakis, Pantelis E.
    Lasaridis, Anastasios
    Protogerou, Athanase D.
    AMERICAN JOURNAL OF NEPHROLOGY, 2014, 40 (03) : 242 - 250
  • [38] Oscillometric blood pressure waveform analysis: challenges and developments
    Balestrieri, Eulalia
    Daponte, Pasquale
    De Vito, Luca
    Picariello, Francesco
    Rapuano, Sergio
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2019,
  • [39] Effect of Peripheral Edema on Oscillometric Blood Pressure Measurement
    Ghaffari, Shamsi
    Malaki, Majid
    Rezaeifar, Afshin
    Fakhim, Shahin Abdollahi
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2014, 6 (04) : 217 - 221
  • [40] BLOOD-PRESSURE MONITORING - AUTOMATED OSCILLOMETRIC DEVICES
    RAMSEY, M
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (01): : 56 - 67