Method for Evaluation of Trustworthiness of Oscillometric Blood Pressure Measurements

被引:0
作者
Koohi, Iraj [1 ]
Ahmad, Saif [1 ]
Batkin, Izmail [1 ]
Groza, Voicu Z. [1 ]
Shirmohammadi, Shervin [1 ]
Dajani, Hilmi R. [1 ]
Petriu, Emil M. [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON, Canada
来源
2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS | 2015年
关键词
Mean arterial pressure; systolic; diastolic; blood pressure; vessel compliance; oscillometric waveform simulation; PULSE-WAVE VELOCITY; ARTERIAL STIFFNESS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simple, unobtrusive, and reliable estimation of cardiovascular parameters is a challenge. We present a novel, simple, and noninvasive method called Ratio2 that provides expected ranges for systolic and diastolic blood pressure values (SBP, DBP) estimated by any algorithm, and an evaluation of vessel compliance. Ratio2 was developed in the frame of the oscillometric blood pressure estimation and it exploits the equality between the arterial blood pressure and the cuff pressure at the mean arterial pressure (MAP). This method is based on the observation that the brachial arterial blood pressure pulses, with MAP used as baseline, are characterized by a peak to trough ratio close to 2. This ratio is employed to characterize expected ranges for estimates of systolic and diastolic blood pressure. Any SBP or DBP measurement which is not contained in these intervals is deemed untrustworthy, and it is marked as such. Ratio2 also provides parameters that are used in a mathematical model of arterial blood pressure (BP) to evaluate vessel stiffness. We tested the performance of the Ratio2 method on 150 oscillometric recordings and their corresponding Omron BP estimates obtained from 10 healthy subjects. Results are encouraging, whereby, (a) out-of-range values obtained with the maximum amplitude algorithm (MAA) and the maximum/minimum slope algorithm (MMSA) methods were successfully detected, and (b) linear correlation between age and vessel compliance is -85% (p<0.005). Therefore, we conclude that the proposed work shows promise towards providing noninvasive BP monitors with an inbuilt mechanism for assessing the fidelity of their BP estimates along with an indicator of vessel compliance.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [21] A novel method for the noninvasive estimation of cardiac output with brachial oscillometric blood pressure measurements through an assessment of arterial compliance
    Alvarez-Montoya, Diego
    Madrid-Munoz, Camilo
    Escobar-Robledo, Luis
    Gallo-Villegas, Jaime
    Aristizabal-Ocampo, Dagnovar
    BLOOD PRESSURE MONITORING, 2021, 26 (06) : 426 - 434
  • [22] Comparison between oscillometric and invasive blood pressure measurements in critically ill premature infants
    Takci, Sahin
    Yigit, Sule
    Korkmaz, Ayse
    Yurdakok, Murat
    ACTA PAEDIATRICA, 2012, 101 (02) : 132 - 135
  • [23] Evaluation of arterial stiffness and hemodynamics by oscillometric method in patients with systemic sclerosis
    Sunbul, Murat
    Tigen, Kursat
    Ozen, Gulsen
    Durmus, Erdal
    Kivrak, Tarik
    Cincin, Altug
    Kepez, Alper
    Atas, Halil
    Direskeneli, Haner
    Basaran, Yelda
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 (15-16) : 461 - 466
  • [24] Intrasession Reliability Analysis for Oscillometric Blood Pressure Method Using a Digital Blood Pressure Monitor in Peruvian Population
    Barrios-Fernandez, Sabina
    Manuel Sosa-Sanchez, Eduardo
    Carlos-Vivas, Jorge
    Munoz-Bermejo, Laura
    Morenas-Martin, Jesus
    Dolores Apolo-Arenas, Maria
    Carmelo Adsuar, Jose
    Javier Dominguez-Munoz, Francisco
    HEALTHCARE, 2022, 10 (02)
  • [25] In vitro and in vivo evaluation of an oscillometric device for monitoring blood pressure in dialysis patients
    Lodi, Carlo Alberto
    Estridge, Charles
    Ghidini, Carlo
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (10) : 2950 - 2961
  • [26] Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs
    Sawyer, DC
    Guikema, AH
    Siegel, EM
    VETERINARY ANAESTHESIA AND ANALGESIA, 2004, 31 (01) : 27 - 39
  • [27] Reliability of oscillometric central blood pressure responses to submaximal exercise
    Lim, Weijie
    Faulkner, James
    Lambrick, Danielle
    Stoner, Lee
    JOURNAL OF HYPERTENSION, 2016, 34 (06) : 1084 - 1090
  • [28] Multi-channel architecture for evaluation of automated oscillometric blood pressure devices
    Postolache, Octavian
    Girao, Pedro Silva
    Postolache, Gabriela
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 207 - 212
  • [29] Indirect blood pressure determination in cats using Doppler ultrasonic and oscillometric method
    Möllenhoff, A
    Nolte, I
    Kramer, S
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2001, 29 (03): : 191 - 197
  • [30] RESEARCHES CONCERNING THE BLOOD PRESSURE IN CLINICALLY HEALTHY DOGS MEASURED BY OSCILLOMETRIC METHOD
    Morar, D.
    Falca, C.
    Mot, T.
    Petruse, Cristina
    REVISTA ROMANA DE MEDICINA VETERINARA, 2012, 22 (01): : 23 - 31