Determination of adenosine phosphates in mouse myocardium tissue by HPLC with UV detection and using porous graphite carbon column

被引:13
作者
Feng, Jia-Hua [1 ]
Wei, Ke-Zhao [1 ]
Gao, Jian-Ping [1 ]
Xu, Xu [2 ]
机构
[1] Shanghai Univ Tradit Chinese Med, Sch Pharm, Shanghai 201203, Peoples R China
[2] Shanghai Inst Technol, Sch Chem & Environm Engn, Shanghai 201418, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2020年 / 1145卷
关键词
HPLC; Porous graphite carbon column; Adenosine phosphates; Energy metabolism; LIQUID-CHROMATOGRAPHY; NUCLEOTIDES; NUCLEOSIDES; SEPARATION; RETENTION; SYSTEM;
D O I
10.1016/j.jchromb.2020.122110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography (HPLC) method with UV detection was established and validated for the simultaneous determination of adenosine triphosphate (ATP), adenosine diphosphate (ADP) and adenosine monophosphate (AMP) in mouse myocardial tissues. After protein precipitation and compound extraction with pre-cooled perchloric acid and the supernatant was centrifuged with the pH value adjusted to 6.5-7.5, the analytes were separated on a porous graphitic carbon LC column (4.6 mm x 100 mm, 5 mu m) using gradient elution with a mobile phase of 10 mmol/L borax solution, pH 9.18(A) and acetonitrile-tetrahydrofuran (1:1, v/v) (B). The LC flow rate was 0.8 mL/min; the UV detection wavelength was 254 nm and the column temperature was maintained at 35 degrees C. ATP, ADP, and AMP were separated and the infra-day relative standard deviations (RSDs) of peak area repeatability were 1.3-2.5% (n = 6). The correlation coefficients of the linearity between UV responses and adenosine phosphate concentrations were larger than 0.9998 in all cases, within concentration ranges of 0.71-91.6 mu g/mL for ATP, 1.3-81.5 mu g/mL for ADP and 1.69-108.1 mu g/mL for AMP. The limits of detection were within 0.17-0.21 mu g/mL. The average standard substance spiked-in recoveries were 93.6-104.7% (n = 3). The established HPLC method was successfully applied to quantitate ATP, ADP, and AMP in mouse myocardial tissues.
引用
收藏
页数:6
相关论文
共 21 条
  • [1] HPLC-UV Method for Simultaneous Determination of Adenosine Triphosphate and Its Metabolites in Mycobacterium smegmatis
    Akhova, Anna V.
    Tkachenko, Alexander G.
    [J]. ACTA CHROMATOGRAPHICA, 2019, 31 (01) : 45 - 48
  • [2] Understanding the Complexity of Porous Graphitic Carbon (PGC) Chromatography: Modulation of Mobile-Stationary Phase Interactions Overcomes Loss of Retention and Reduces Variability
    Bapiro, Tashinga E.
    Richards, Frances M.
    Jodrell, Duncan I.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (12) : 6190 - 6194
  • [3] A sensitive method for the separation and quantification of low-level adenine nucleotides using porous graphitic carbon-based liquid chromatography and tandem mass spectrometry
    Bustamante, Sonia
    Gilchrist, Robert B.
    Richani, Dulama
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1061 : 445 - 451
  • [4] Mitochondrial ion transport pathways: Role in metabolic diseases
    Cardoso, Ariel R.
    Queliconi, Bruno B.
    Kowaltowski, Alicia J.
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2010, 1797 (6-7): : 832 - 838
  • [5] Eluotropic strength in non-aqueous liquid chromatography with porous graphitic carbon
    Gaudin, K
    Chaminade, P
    Baillet, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) : 61 - 68
  • [6] Separation of polar compounds using carbon columns
    Hanai, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 989 (02) : 183 - 196
  • [7] Retention studies of 2′-2′-difluorodeoxycytidine and 2′-2′-difluorodeoxyuridine nucleosides and nucleotides on porous graphitic carbon: Development of a liquid chromatography-tandem mass spectrometry method
    Jansen, Robert S.
    Rosing, Hilde
    Schellens, Jan H. M.
    Beijnen, Jos H.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 3168 - 3174
  • [8] CELLULAR-ENERGY METABOLISM AND REGULATION
    KELLY, JM
    SUMMERS, M
    PARK, HS
    MILLIGAN, LP
    MCBRIDE, BW
    [J]. JOURNAL OF DAIRY SCIENCE, 1991, 74 (02) : 678 - 694
  • [9] Liu F., 2010, ANAL TESTING TECHNOL, V16, P71
  • [10] Lv L., 2013, J Anal Sci Meth Instrum, V03, P17, DOI DOI 10.4236/JASMI.2013.33A003