Flexural capacity of singly reinforced beam with 150 MPa ultra high-strength concrete

被引:0
作者
Shin, Sung-woo [1 ]
Kang, Hoon [1 ]
Ahn, Jong-mun [2 ]
Kim, Do-woo [1 ]
机构
[1] Hanyang Univ, Dept Architectural Engn, Seoul, South Korea
[2] Ansan Coll, Dept Architectural Engn, Ansan, South Korea
关键词
Ultra-high-strength-concrete; Maximum tensile steel ratio; Ductility; Flexural behavior;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, we have studied the 150 MPa ultra-high-strength concrete (UHSC). RC beam is reinforced by SD400 and SD500 bars to evaluate on range of maximum tensile steel ratio which have reasonable ductility capacities and flexural behaviors of UHSC through the flexural test. The reinforced ultra-high-strength-concrete beam subjected to flexural moment behaves more brittleness than the reinforced moderate strength concrete beam with equal reinforcement ratio (rho/rho(b), rho(b)=balanced steel ratio). In this study, 10 singly reinforced rectangular beam specimens using 150 MPa concrete compressive strength are tested to evaluate on flexural behavior. The ductility capacity of UHSC flexural member without compression reinforcements significantly decrease. Displacement ductility index indicates about 1.3 similar to 2.56 on 150 MPa UHSC. To obtain the minimum ductility ratio with above 3.0 for double reinforced beam and above 2.0 for singly reinforced beam, limit strain shall be set so that the net tensile strain of outermost tensile steel may be above 0.006 in excess of 0.005 and the tensile steel ratio is required to be 0.55 rho(b) or less.
引用
收藏
页码:414 / 426
页数:13
相关论文
共 17 条
[1]  
*ACI COMM, 2002, 31802 ACI COMM
[2]  
*ACI COMM, 2002, 31802 ACI COMM, P6
[3]  
BLUME JA, 1961, DESIGN MULTYSTORY RE
[4]  
JEONG CG, 1997, THESIS HANYANG U
[5]  
MCGREGOR JG, HDB CONCRETE ENG
[6]  
*MIN LAND TRANSP M, 2007, STAND CONCR STRUCT D
[7]  
PARK R, 1988, ACI STRUCT J, P217
[8]  
Rashid MA, 2005, ACI STRUCT J, V102, P462
[9]  
RICHARD WF, 1970, ACI J P, V67, P341
[10]  
SHIN SW, 1989, ACI STRUCT J, V86, P394