Predicting Severity of Huntington's Disease With Wearable Sensors

被引:7
作者
Scheid, Brittany H. [1 ,2 ]
Aradi, Stephen [3 ,4 ,5 ]
Pierson, Robert M. [1 ,2 ]
Baldassano, Steven [6 ]
Tivon, Inbar [1 ]
Litt, Brian [1 ,2 ,3 ]
Gonzalez-Alegre, Pedro [3 ,4 ,7 ]
机构
[1] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[2] Univ Penn, Ctr Neuroengn & Therapeut, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA USA
[4] Univ Penn, Huntingtons Dis Ctr Excellence, Philadelphia, PA USA
[5] Univ S Florida, Dept Neurol, Tampa, FL USA
[6] Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[7] Spark Therapeut, Philadelphia, PA USA
来源
FRONTIERS IN DIGITAL HEALTH | 2022年 / 4卷
关键词
movement disorders; biosensors; gait; accelerometer; Huntington's disease (HD); machine learning; wearables; RATING-SCALE; RELIABILITY; IMPAIRMENT;
D O I
10.3389/fdgth.2022.874208
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The Unified Huntington's Disease Rating Scale (UHDRS) is the primary clinical assessment tool for rating motor function in patients with Huntington's disease (HD). However, the UHDRS and similar rating scales (e.g., UPDRS) are both subjective and limited to in-office assessments that must be administered by a trained and experienced rater. An objective, automated method of quantifying disease severity would facilitate superior patient care and could be used to better track severity over time. We conducted the present study to evaluate the feasibility of using wearable sensors, coupled with machine learning algorithms, to rate motor function in patients with HD. Fourteen participants with symptomatic HD and 14 healthy controls participated in the study. Each participant wore five adhesive biometric sensors applied to the trunk and each limb while completing brief walking, sitting, and standing tasks during a single office visit. A two-stage machine learning method was employed to classify participants by HD status and to predict UHDRS motor subscores. Linear discriminant analysis correctly classified all participants' HD status except for one control subject with abnormal gait (96.4% accuracy, 92.9% sensitivity, and 100% specificity in leave-one-out cross-validation). Two regression models accurately predicted individual UHDRS subscores for gait, and dystonia within a 10% margin of error. Our regression models also predicted a composite UHDRS score-a sum of left and right arm rigidity, total chorea, total dystonia, bradykinesia, gait, and tandem gait subscores-with an average error below 15%. Machine learning classifiers trained on brief in-office datasets discriminated between controls and participants with HD, and could accurately predict selected motor UHDRS subscores. Our results could enable the future use of biosensors for objective HD assessment in the clinic or remotely and could inform future studies for the use of this technology as a potential endpoint in clinical trials.
引用
收藏
页数:7
相关论文
共 25 条
[1]   Wearable Sensors in Huntington Disease: A Pilot Study [J].
Andrzejewski, Kelly L. ;
Dowling, Ariel V. ;
Stamler, David ;
Felong, Timothy J. ;
Harris, Denzil A. ;
Wong, Cynthia ;
Cai, Hang ;
Reilmann, Ralf ;
Little, Max A. ;
Gwin, Joseph T. ;
Biglan, Kevin M. ;
Dorsey, E. Ray .
JOURNAL OF HUNTINGTONS DISEASE, 2016, 5 (02) :199-206
[2]   Wavelet-based characterization of gait signal for neurological abnormalities [J].
Baratin, E. ;
Sugavaneswaran, L. ;
Umapathy, K. ;
Ioana, C. ;
Krishnan, S. .
GAIT & POSTURE, 2015, 41 (02) :634-639
[3]   Automated Assessment of Movement Impairment in Huntington's Disease [J].
Bennasar, M. ;
Hicks, Y. A. ;
Clinch, S. P. ;
Jones, P. ;
Holt, C. ;
Rosser, A. ;
Busse, M. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (10) :2062-2069
[4]   Huntington's Disease Assessment Using Tri Axis Accelerometers [J].
Bennasar, Mohamed ;
Hicks, Yulia ;
Clinch, Susanne ;
Jones, Philippa ;
Rosser, Anne ;
Busse, Monica ;
Holt, Cathy .
KNOWLEDGE-BASED AND INTELLIGENT INFORMATION & ENGINEERING SYSTEMS: PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE KES-2016, 2016, 96 :1193-1201
[5]   Quantitative biomechanical assessment of trunk control in Huntington's disease reveals more impairment in static than dynamic tasks [J].
Deb, Kegelmeyer A. ;
Sandra, Kostyk K. ;
Nora, Fritz E. ;
Marianne, Fiumedora M. ;
Ajit, Chaudhari ;
Marilly, Palettas ;
Gregory, Young ;
Anne, Kloos D. .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 376 :29-34
[6]   A Longitudinal Wearable Sensor Study in Huntington's Disease [J].
Dinesh, Karthik ;
Snyder, Christopher W. ;
Xiong, Mulin ;
Tarolli, Christopher G. ;
Sharma, Saloni ;
Dorsey, E. Ray ;
Sharma, Gaurav ;
Adams, Jamie L. .
JOURNAL OF HUNTINGTONS DISEASE, 2020, 9 (01) :69-81
[7]   Objective measurement in routine care of people with Parkinson's disease improves outcomes [J].
Farzanehfar, Parisa ;
Woodrow, Holly ;
Braybrook, Michelle ;
McGregor, Sarah ;
Evans, Andrew ;
Nicklason, Frank ;
Horne, Malcolm .
NPJ PARKINSONS DISEASE, 2018, 4
[8]  
Gordon Mark Forrest, 2019, Digit Biomark, V3, P103, DOI 10.1159/000502136
[9]  
Hastie T., 2009, The Elements of Statistical Learning: Data Mining, Inference and Prediction, V2nd, DOI [10.1007/978-0-387-84858-7, DOI 10.1007/978-0-387-84858-7]
[10]  
Heldman D, 2017, NEUROLOGY, V88, DOI 10.1159/000475801