Four-Dimensional Flow Assessment of Pulmonary Artery Flow and Wall Shear Stress in Adult Pulmonary Arterial Hypertension: Results from Two Institutions

被引:104
|
作者
Barker, Alex J. [1 ]
Roldan-Alzate, Alejandro [2 ,3 ]
Entezari, Pegah [1 ]
Shah, Sanjiv J. [4 ]
Chesler, Naomi C. [5 ]
Wieben, Oliver [2 ,3 ]
Markl, Michael [1 ,6 ]
Francois, Christopher J. [2 ,3 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[4] Northwestern Univ, Div Cardiol, Feinberg Sch Med, Chicago, IL 60611 USA
[5] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[6] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
pulmonary hypertension; 4D flow MRI; wall shear stress; CARDIOVASCULAR MAGNETIC-RESONANCE; BLOOD-FLOW; INTRACELLULAR CALCIUM; DIASTOLIC FUNCTION; HEART; REPRODUCIBILITY; PATTERNS; MASS; MRI; RESISTANCE;
D O I
10.1002/mrm.25326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare pulmonary artery flow using Cartesian and radially sampled four-dimensional flow-sensitive (4D flow) MRI at two institutions. MethodsNineteen healthy subjects and 17 pulmonary arterial hypertension (PAH) subjects underwent a Cartesian 4D flow acquisition (institution 1) or a three-dimensional radial acquisition (institution 2). The diameter, peak systolic velocity (Vmax), peak flow (Qmax), stroke volume (SV), and wall shear stress (WSS) were computed in two-dimensional analysis planes at the main, right, and left pulmonary artery. Interobserver variability, interinstitutional differences, flow continuity, and the hemodynamic measurements in healthy and PAH subjects were assessed. ResultsVmax, Qmax, SV, and WSS at all locations were significantly lower (P<0.05) in PAH compared with healthy subjects. The limits of agreement were 0.16 m/s, 2.4 L/min, 10 mL, and 0.31 N/m(2) for Vmax, Qmax, SV, and WSS, respectively. Differences between Qmax and SV using Cartesian and radial sequences were not significant. Plane placement and acquisition exhibited isolated, site-based differences between Vmax and WSS. Conclusions4D flow MRI was used to detect differences in pulmonary artery hemodynamics for PAH subjects. Flow and WSS in healthy and PAH subject cohorts were similar between Cartesian- and radial-based 4D flow MRI acquisitions with minimal interobserver variability. Magn Reson Med 73:1904-1913, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1904 / 1913
页数:10
相关论文
共 50 条
  • [31] Phase-contrast magnetic resonance imaging for analyzing hemodynamic parameters and wall shear stress of pulmonary arteries in patients with pulmonary arterial hypertension
    Hung-Hsuan Wang
    Wen-Yih Isaac Tseng
    Hsi-Yu Yu
    Meng-Chu Chang
    Hsu-Hsia Peng
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 617 - 627
  • [32] Validation of cardiac index measured by four-dimensional cardiac magnetic resonance flow against the invasively measured cardiac index in patients with pulmonary hypertension
    Romeih, Soha
    Elkafrawy, Fatma
    Shaaban, Mahmoud
    Hassan, Ahmed
    Samuel, Irini
    Gergis, Micheal
    El Mozy, Wesam
    Yacoub, Magdi
    PULMONARY CIRCULATION, 2023, 13 (01)
  • [33] Characteristics of pulmonary arterial flow derived from phase contrast magnetic resonance imaging in patients with pulmonary arterial hypertension: correlations with right ventricular function and hemodynamics
    Li, Wen
    Yang, Tao
    Zhang, Yan
    Wang, Hao
    Gu, Qing
    Zhao, Zhi-Hui
    Ni, Xin-Hai
    Liu, Zhi-Hong
    Xiong, Chang-Ming
    He, Jian-Guo
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (12): : 23386 - 23396
  • [34] Analysis of right ventricular flow with 4-dimensional flow cardiovascular magnetic resonance imaging in patients with pulmonary arterial hypertension
    Wang, Lei
    Liu, Min
    Zhang, Pei Yao
    Dai, Jin Zhu
    Ma, Hai Yi
    Tao, Xin Cao
    Xie, Wan Mu
    Wan, Jun
    Jing, An
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (08) : 3655 - 3665
  • [35] Hemodynamic Assessment of Celiaco-mesenteric Anastomosis in Patients with Pancreaticoduodenal Artery Aneurysm Concomitant with Celiac Artery Occlusion using Flow-sensitive Four-dimensional Magnetic Resonance Imaging
    Mano, Y.
    Takehara, Y.
    Sakaguchi, T.
    Alley, M. T.
    Isoda, H.
    Shimizu, T.
    Wakayama, T.
    Sugiyama, M.
    Sakahara, H.
    Konno, H.
    Unno, N.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (03) : 321 - 328
  • [36] Flow-sensitive four-dimensional magnetic resonance imaging facilitates the quantitative analysis of systemic-to-pulmonary collateral flow in patients with univentricular hearts
    Sarah Nordmeyer
    Israel Valverde
    Sergio Uribe
    Gerald F Greil
    Felix Berger
    Titus Kuehne
    Philipp B Beerbaum
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [37] Assessment of Pulmonary Arterial Hypertension and Vascular Resistance by Measurements of the Pulmonary Arterial Flow Velocity Curve in the Absence of a Measurable Tricuspid Regurgitant Velocity in Childhood Congenital Heart Disease
    Ayhan Cevik
    Serdar Kula
    Rana Olgunturk
    F. Sedef Tunaoglu
    A. Deniz Oguz
    Berna Saylan
    Erman Cilsal
    Cihat Sanli
    Pediatric Cardiology, 2013, 34 : 646 - 655
  • [38] Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins
    Sun, Xue
    Zhang, Ying
    Fan, Miao
    Wang, Yu
    Wang, Meilian
    Siddiqui, Faiza Amber
    Sun, Wei
    Sun, Feifei
    Zhang, Dongyu
    Lei, Wenjia
    Hu, Guyue
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (06): : 906 - 914
  • [39] Assessment of Pulmonary Arterial Hypertension and Vascular Resistance by Measurements of the Pulmonary Arterial Flow Velocity Curve in the Absence of a Measurable Tricuspid Regurgitant Velocity in Childhood Congenital Heart Disease
    Cevik, Ayhan
    Kula, Serdar
    Olgunturk, Rana
    Tunaoglu, F. Sedef
    Oguz, A. Deniz
    Saylan, Berna
    Cilsal, Erman
    Sanli, Cihat
    PEDIATRIC CARDIOLOGY, 2013, 34 (03) : 646 - 655
  • [40] Flow-sensitive four-dimensional magnetic resonance imaging facilitates and improves the accurate diagnosis of partial anomalous pulmonary venous drainage
    Nordmeyer, Sarah
    Berger, Felix
    Kuehne, Titus
    Riesenkampff, Eugenie
    CARDIOLOGY IN THE YOUNG, 2011, 21 (05) : 528 - 535