Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom

被引:62
作者
Komlosh, Michal E. [1 ]
Oezarslan, Evren [1 ]
Lizak, Martin J. [2 ]
Horkay, Ferenc [1 ]
Schram, Vincent [3 ]
Shemesh, Noam [4 ]
Cohen, Yoram [4 ]
Basser, Peter J. [1 ]
机构
[1] NICHD, Sect Tissue Biophys & Biomimet, Program Pediat Imaging & Tissue Sci, NIH, Bethesda, MD 20892 USA
[2] NINDS, NMRF, NIH, Bethesda, MD USA
[3] NICHD, NIH, Bethesda, MD USA
[4] Tel Aviv Univ, Raymond & Beverly Sackler Sch Exact Sci, Sch Chem, Ramat Aviv, Israel
关键词
Double; Pulsed-field gradient; PEG; D-PFG; NMR; MRI; Diffusion; DWI; Validation; Phantom; Wave vector; Microcapillary; Array; GCA; Restricted; Cross-term; Pore diameter; EXPERIMENTAL PARAMETERS; DIFFUSION-DIFFRACTION; WATER DIFFUSION; SELF-DIFFUSION; AXON DIAMETER; NMR DIFFUSION; SPINAL-CORD; ANISOTROPY; MATTER; TENSOR;
D O I
10.1016/j.jmr.2010.10.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Double pulsed-field gradient (d-PFG) MRI can provide quantitative maps of microstructural quantities and features within porous media and tissues. We propose and describe a novel MRI phantom, consisting of wafers of highly ordered glass capillary arrays (GCA), and its use to validate and calibrate a d-PFG MRI method to measure and map the local pore diameter. Specifically, we employ d-PFG Spin-Echo Filtered MRI in conjunction with a recently introduced theoretical framework, to estimate a mean pore diameter in each voxel within the imaging volume. This simulation scheme accounts for all diffusion and imaging gradients within the diffusion weighted MRI (DWI) sequence, and admits the violation of the short gradient pulse approximation. These diameter maps agree well with pore sizes measured using both optical microscopy and single PFG diffusion diffraction NMR spectroscopy using the same phantom. Pixel-by-pixel analysis shows that the local pore diameter can be mapped precisely and accurately within a specimen using d-PFG MRI. (C) 2010 Published by Elsevier Inc.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 36 条
[21]   NMR ''diffusion-diffraction'' of water revealing alignment of erythrocytes in a magnetic field and their dimensions and membrane transport characteristics [J].
Kuchel, PW ;
Coy, A ;
Stilbs, P .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :637-643
[22]   SELF-DIFFUSION IN NORMAL AND HEAVY-WATER IN RANGE 1-45 DEGREES [J].
MILLS, R .
JOURNAL OF PHYSICAL CHEMISTRY, 1973, 77 (05) :685-688
[23]   EFFECTS OF FINITE GRADIENT-PULSE WIDTHS IN PULSED-FIELD-GRADIENT DIFFUSION MEASUREMENTS [J].
MITRA, PP ;
HALPERIN, BI .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 113 (01) :94-101
[24]   MULTIPLE WAVE-VECTOR EXTENSIONS OF THE NMR PULSED-FIELD-GRADIENT SPIN-ECHO DIFFUSION MEASUREMENT [J].
MITRA, PP .
PHYSICAL REVIEW B, 1995, 51 (21) :15074-15078
[25]   Microscopic anisotropy revealed by NMR double pulsed field gradient experiments with arbitrary timing parameters [J].
Oezarslan, Evren ;
Basser, Peter J. .
JOURNAL OF CHEMICAL PHYSICS, 2008, 128 (15)
[26]   MR diffusion-"diffraction" phenomenon in multi-pulse-field-gradient experiments [J].
Oezarslan, Evren ;
Basser, Peter J. .
JOURNAL OF MAGNETIC RESONANCE, 2007, 188 (02) :285-294
[27]   Indirect measurement of regional axon diameter in excised mouse spinal cord with q-space imaging:: Simulation and experimental studies [J].
Ong, Henry H. ;
Wright, Alex C. ;
Wehrli, Suzanne L. ;
Souza, Andre ;
Schwartz, Eric D. ;
Hwang, Scott N. ;
Wehrli, Felix W. .
NEUROIMAGE, 2008, 40 (04) :1619-1632
[28]   Compartment shape anisotropy (CSA) revealed by double pulsed field gradient MR [J].
Ozarslan, Evren .
JOURNAL OF MAGNETIC RESONANCE, 2009, 199 (01) :56-67
[29]   A general framework to quantify the effect of restricted diffusion on the NMR signal with applications to double pulsed field gradient NMR experiments [J].
Ozarslan, Evren ;
Shemesh, Noam ;
Basser, Peter J. .
JOURNAL OF CHEMICAL PHYSICS, 2009, 130 (10)
[30]   SPIN-ECHO DECAY OF SPINS DIFFUSING IN A BOUNDED REGION [J].
ROBERTSON, B .
PHYSICAL REVIEW, 1966, 151 (01) :273-+