Retrograde Transcatheter Closure of Ventricular Septal Defects in Children Using The Amplatzer Duct Occluder II

被引:27
作者
Koneti, Nageswara Rao [1 ]
Penumatsa, Raghava Raju [1 ]
Kanchi, Vasudevan [1 ]
Arramraj, Srinivas Kumar [1 ]
Jaishankar, S. [1 ]
Bhupathiraju, Somaraju [1 ]
机构
[1] Care Hosp, Inst Med Sci, Dept Pediat Cardiol, Hyderabad, Andhra Pradesh, India
关键词
congenital heart defects; left to right shunts; endovascular closure; ventricular septal defect; septal occluder device; MEMBRANOUS VSD OCCLUDER; DEVICE CLOSURE; EXPERIENCE;
D O I
10.1002/ccd.22675
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To describe the technique and results of transcatheter closure of ventricular septal defects (VSDs) by a modified retrograde transarterial approach using the new Amplatzer Duct Occluder II (ADO II). Background: Transcatheter device closure of ventricular septal defects (VSDs) by antegrade method is well established, but a challenging procedure. We describe a retrograde technique that obviates the need for arteriovenous looping. Material and Methods: This is a prospective study from a single center. Between April 2009 and February 2010 13 children were identified for closure of various types of perimembranous and muscular VSDs using the ADO II device. All had met the criteria for surgical closure. Following left ventricular angiogram two were excluded as technically nonfeasible. The median age was 48 months (range 15-78). The median weight was 14 kg (range 7.5-20). The device was successfully deployed in the 11 selected children by the method described. The follow-up evaluation included chest roentgenogram, ECG, and echocardiogram on day 1, at 6 weeks, at 3, 6, and 12 months. Results: The immediate and follow up complete closure rates were 73 and 82%, respectively. The median fluoroscopic time was 14 min (range 8.2-45). There were no procedure related complications. All patients were doing well at median follow up of 10 months; none showing any conduction abnormality. Conclusion: Transcatheter retrograde device closure of selected cases of Ventricular Septal Defects using the Amplatzer Duct Occluder II is simple and appears safe in the short term and can be completed within a short fluoroscopic time. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:252 / 259
页数:8
相关论文
共 14 条
  • [1] Initial human experience with the Amplatzer perimembranous ventricular septal occluder device
    Bass, JL
    Kalra, GS
    Arora, R
    Masura, J
    Gavora, P
    Thanopoulos, BD
    Torres, W
    Sievert, H
    Carminati, M
    Fischer, G
    Ewert, P
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) : 238 - 245
  • [2] Clinical Evaluation of the New Amplatzer Duct Occluder II for Patent Arterial Duct Occlusion
    Bhole, V.
    Miller, P.
    Mehta, C.
    Stumper, O.
    Reinhardt, Z.
    De Giovanni, J. V.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (05) : 762 - 769
  • [3] Transcatheter closure of congenital ventricular septal defect with amplatzer septal occluders
    Carminati, M
    Butera, G
    Chessa, M
    Drago, M
    Negura, D
    Piazza, L
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (12A) : 52L - 58L
  • [4] NATURAL-HISTORY OF VENTRICULAR SEPTAL-DEFECT - STUDY INVOLVING 790 CASES
    CORONE, P
    DOYON, F
    GAUDEAU, S
    GUERIN, F
    VERNANT, P
    DUCAM, H
    RUMEAUROUQUETTE, C
    GAUDEUL, P
    [J]. CIRCULATION, 1977, 55 (06) : 908 - 915
  • [5] The Amplatzer® Membranous VSD Occluder and the vulnerability of the atrioventricular conduction system
    Fischer, Gunther
    Apostolopoulou, Sotiria C.
    Rammos, Spyros
    Schneider, Martin B.
    Bjornstad, Per G.
    Kramer, Hans Heiner
    [J]. CARDIOLOGY IN THE YOUNG, 2007, 17 (05) : 499 - 504
  • [6] Experimental Evaluation of a New Articulated Amplatzer® Ductal Occluder Device Without Fabric
    Gruenstein, Daniel H.
    Bass, John L.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (03) : 482 - 487
  • [7] Catheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder: Initial clinical experience
    Hijazi, ZM
    Hakim, F
    Abu Haweleh, A
    Madani, A
    Tarawna, W
    Hiari, A
    Cao, OL
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) : 508 - 515
  • [8] Hijazi ZM, 2000, CATHETER CARDIO INTE, V49, P167, DOI 10.1002/(SICI)1522-726X(200002)49:2<167::AID-CCD11>3.0.CO
  • [9] 2-S
  • [10] Device closure of muscular ventricular septal defects using the amplatzer muscular ventricular septal defect occluder - Immediate and mid-term results of a US registry
    Holzer, R
    Balzer, D
    Cao, QL
    Lock, K
    Hijazi, ZM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1257 - 1263