Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions

被引:93
作者
Anadioti, Evanthia [1 ]
Aquilino, Steven A. [2 ]
Gratton, David G. [2 ]
Holloway, Julie A. [2 ]
Denry, Isabelle L. [2 ]
Thomas, Geb W. [3 ]
Qian, Fang [4 ]
机构
[1] Boston Univ, Goldman Sch Dent Med, Dept Gen Dent, Boston, MA 02118 USA
[2] Univ Iowa, Coll Dent, Dept Prosthodont, Iowa City, IA 52242 USA
[3] Univ Iowa, Coll Engn, Mech & Ind Engn, Iowa City, IA 52242 USA
[4] Univ Iowa, Coll Dent, Dept Prevent & Community Dent, Iowa City, IA 52242 USA
关键词
CAD/CAM SYSTEMS; RESTORATIONS; THICKNESS; CASTINGS;
D O I
10.1016/j.prosdent.2014.09.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. No studies have evaluated the internal adaptation of pressed and milled ceramic crowns made from digital impressions. Purpose. The purpose of this in vitro study was to evaluate the internal fit of pressed and milled ceramic crowns made from digital and conventional impressions. Material and methods. Thirty polyvinyl siloxane (PVS) impressions and 30 Lava COS impressions made of a prepared dentoform tooth (master die) were fabricated. Thirty crowns were pressed in lithium disilicate (IPS e.max Press), and 30 crowns were milled from lithium disilicate blocks (IPS e.max CAD) (15/impression technique) with the E4D scanner and milling engine. The master die and the intaglio of the crowns were digitized with a 3-dimensional laser coordinate measurement machine. The digital master die and intaglio of each crown were merged. The distance between the die and the intaglio surface of the crown was measured at 3 standardized points. One-way ANOVA was used for statistical analysis (alpha=.05). Results. One-way ANOVA revealed that the internal gap obtained from the Lava/press group (0.211 mm, +/- SD 0.041) was significantly greater than that obtained from the other groups (P<.001), while no significant differences were found among PVS/press (0.111 mm +/- SD 0.047), PVS/CAD/CAM (0.116 mm +/- SD 0.02), and Lava/CAD/CAM (0.145 mm +/- SD 0.024). Conclusions. The combination of the digital impression and pressed crown produced the least accurate internal fit.
引用
收藏
页码:304 / 309
页数:6
相关论文
共 17 条
[1]  
Anadioti E., 2014, J Prosthodont, P1
[2]  
Chen Yu, 2012, J Pathol Inform, V3, P22, DOI 10.4103/2153-3539.96751
[3]   Ceramics for Dental Applications: A Review [J].
Denry, Isabelle ;
Holloway, Julie A. .
MATERIALS, 2010, 3 (01) :351-368
[4]   TECHNIQUES TO IMPROVE SEATING OF CASTINGS [J].
EAMES, WB ;
ONEAL, SJ ;
MONTEIRO, J ;
MILLER, C ;
ROAN, JD ;
COHEN, KS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1978, 96 (03) :432-437
[5]   A MATHEMATICAL TREATISE ON THE FIT OF CROWN CASTINGS [J].
GRAJOWER, R ;
LEWINSTEIN, I .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 49 (05) :663-674
[6]   Ceramics as biomaterials for dental restoration [J].
Hoeland, Wolfram ;
Schweiger, Marcel ;
Watzke, Ronny ;
Peschke, Arnd ;
Kappert, Heinrich .
EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (06) :729-745
[7]  
Holst S, 2010, IFMBE PROC, V31, P1479, DOI 10.1007/978-3-642-14515-5_377
[8]  
Holst S, 2011, QUINTESSENCE INT, V42, P651
[9]   Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems [J].
Lee, Kyu-Bok ;
Park, Charn-Woon ;
Kim, Kyo-Han ;
Kwon, Tae-Yub .
DENTAL MATERIALS JOURNAL, 2008, 27 (03) :422-426
[10]   The Effects of Adhesive Type and Thickness on Stress Distribution in Molars Restored with All-Ceramic Crowns [J].
Liu, Bin ;
Lu, Chenglin ;
Wu, Yanling ;
Zhang, Xiuyin ;
Arola, Dwayne ;
Zhang, Dongsheng .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (01) :35-44