Soft tissue artefact in the thoracic spine during axial rotation and arm elevation using ultrasound imaging: A descriptive study

被引:21
作者
Heneghan, Nicola R. [1 ]
Balanos, George M. [1 ]
机构
[1] Univ Birmingham, Sch Sport & Exercise Sci, Birmingham B15 2TT, W Midlands, England
关键词
Thoracic spine; Skin tissue artefact; Motion analysis; Ultrasound; IN-VIVO; KINEMATICS; PALPATION; MOVEMENTS; MOTION; LEVEL; MODEL;
D O I
10.1016/j.math.2010.05.004
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Much of the current understanding of thoracic motion analysis is based on the use of skin sensors or markers. Skin tissue artefact, movement occurring between the skin and underlying bone, is readily acknowledged by researchers as a source or measurement error, yet to date has not been quantified. The aim of this study was therefore to evaluate skin tissue artefact, during thoracic axial rotation and single arm elevation. Using an ultrasound imaging technique this study describes soft tissue artefact in the thoracic spine during axial rotation and single arm elevation in sitting using 30 asymptomatic individuals. The findings from this study indicate that soft tissue artefact (STA) in the mid thoracic region ranges between 14 and 16 mm for 35-degrees of rotation. During single arm elevation 0.8-1.5 mm STA was measured at the levels of T1-T6-T12. The results of this study suggests that STA is a considerable and variable source of error in all regions of the thoracic spine, but most notably for the mid thoracic region during axial rotation. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:599 / 602
页数:4
相关论文
共 16 条
[1]   Studies of human locomotion: past, present and future [J].
Andriacchi, TP ;
Alexander, EJ .
JOURNAL OF BIOMECHANICS, 2000, 33 (10) :1217-1224
[2]   Reproducibility and repeatability: errors of three groups of physiotherapists in locating spinal levels by palpation [J].
Billis, EV ;
Foster, NE ;
Wright, CC .
MANUAL THERAPY, 2003, 8 (04) :223-232
[3]   Non-invasive approach towards the in vivo estimation of 3D inter-vertebral movements: methods and preliminary results [J].
Cerveri, P ;
Pedotti, A ;
Ferrigno, G .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (10) :841-853
[4]  
EDMONSTON S, 2006, J MANIP PHYSIOL THER, V30, P193
[5]   Investigation of soft tissue movement during level walking: Translations and rotations of skin markers [J].
Gao, Bo ;
Zheng, Naiquan .
JOURNAL OF BIOMECHANICS, 2008, 41 (15) :3189-3195
[6]   A new model to facilitate palpation of the level of the transverse processes of the thoracic spine [J].
Geelhoed, Michael A. ;
McGaugh, Janna ;
Brewer, Patricia A. ;
Murphy, Douglas .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (11) :876-881
[7]   Stability and intra-tester reliability of an in vivo measurement of thoracic axial rotation using an innovative methodology [J].
Heneghan, Nicola R. ;
Hall, Alison ;
Hollands, Mark ;
Balanos, George M. .
MANUAL THERAPY, 2009, 14 (04) :452-455
[8]  
Kirby A, 1999, RES SPINAL DEFORMITI, V59
[9]   Human movement analysis using stereophotogrammetry - Part 3. Soft tissue artifact assessment and compensation [J].
Leardini, A ;
Chiari, L ;
Della Croce, U ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :212-225
[10]   A three-dimensional MRI analysis of knee kinematics [J].
Patel, VV ;
Hall, K ;
Ries, M ;
Lotz, J ;
Ozhinsky, E ;
Lindsey, C ;
Lu, Y ;
Majumdar, S .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) :283-292