In situ measurement method for the quantification of the thermal transmittance of a non-homogeneous wall or a thermal bridge using an inverse technique and active infrared thermography
被引:24
作者:
Francois, Adrien
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris Est Creteil, CERTES, F-94010 Creteil, France
St Gobain Res Paris, 39 Quai Lucien Lefranc, F-93300 Aubervilliers, FranceUniv Paris Est Creteil, CERTES, F-94010 Creteil, France
Francois, Adrien
[1
,2
]
Ibos, Laurent
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris Est Creteil, CERTES, F-94010 Creteil, FranceUniv Paris Est Creteil, CERTES, F-94010 Creteil, France
Ibos, Laurent
[1
]
Feuillet, Vincent
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris Est Creteil, CERTES, F-94010 Creteil, FranceUniv Paris Est Creteil, CERTES, F-94010 Creteil, France
Feuillet, Vincent
[1
]
Meulemans, Johann
论文数: 0引用数: 0
h-index: 0
机构:
St Gobain Res Paris, 39 Quai Lucien Lefranc, F-93300 Aubervilliers, FranceUniv Paris Est Creteil, CERTES, F-94010 Creteil, France
Meulemans, Johann
[2
]
机构:
[1] Univ Paris Est Creteil, CERTES, F-94010 Creteil, France
[2] St Gobain Res Paris, 39 Quai Lucien Lefranc, F-93300 Aubervilliers, France
in situ;
Measurements;
Thermal resistance;
Thermal bridges;
Building envelope;
Inverse methods;
Heat transfer coefficient;
Active infrared thermography;
Non-destructive testing (NDT);
BUILDING ENVELOPE;
EXPERIMENTAL VALIDATION;
ENERGY PERFORMANCE;
INSULATION DEFECTS;
IMPACT;
DIFFUSIVITY;
IMPROVEMENT;
LOSSES;
D O I:
10.1016/j.enbuild.2020.110633
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
Thermal bridges tend to increase overall buildings energy demand and might cause water condensation problems. They are thermally characterized by a linear transmission coefficient psi or a point transmission coefficient chi. Today, most studies of thermal bridges are based on theoretical or numerical calculations. Standardized methods define default values and assumptions to make in simple or detailed simulations. The few existing in situ characterization methods of thermal bridges are based on steady-state assumptions. This makes them highly sensitive to weather conditions and often requires very long measurements. The present paper proposes a novel active method for the in situ characterization of a thermal bridge. It generalizes a measurement of a homogeneous wall thermal resistance. The indoor air is rapidly heated for a few hours (typically 6) and the wall thermal response is analyzed with an inverse technique based on a white-box model. Surface temperatures and heat fluxes are measured with contact sensors on a sound area and these quantities are then extrapolated to nearby thermal bridges using infrared thermography. The total heat transfer coefficient, required in the heat flux extrapolation process, is monitored with a specific device. The method is validated on a full-size load-bearing wall built inside a climate chamber. The mechanical supports, holding the internal insulation system implemented on the wall, generate several thermal bridges. The psi-values estimated by the active method are less than 20% away from steady-state measurements taken as reference. Many configurations were tested with constant and varying external temperature and the method proved its robustness to these unsteady conditions. (C) 2020 Elsevier B.V. All rights reserved.