Interlayer spray ionization mass spectrometry for the simple direct analysis of low amounts of sample

被引:10
作者
Chen, Jin [1 ]
Tang, Fei [1 ]
Guo, Cheng'an [1 ]
Huo, Xinming [1 ]
Zhang, Sichun [2 ]
Wang, Xiaohao [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Beijing Key Lab Microanalyt Methods & Instrumenta, Dept Chem, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Ionization source; Trace analysis; Sandwich structure; Interlayer spray; Mass spectrometry; PAPER SPRAY; ELECTROSPRAY-IONIZATION; QUANTITATIVE-ANALYSIS; NANO-ELECTROSPRAY; DRUGS; MS;
D O I
10.1007/s00216-016-9600-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Interlayer spray is proposed as a convenient ionization source for direct analysis by mass spectrometry. Two slices of non-absorbent substrate hold the liquid sample to form a sandwich structure. By applying a high voltage to the sample, spray is generated at the tip of the substrate. The sampling procedure can be operated easily in an open condition and the spray is processed in a semi-enclosed condition, which leads to a relatively stable process. An ultralow amount (< 2 mu L) of the liquid sample can be analyzed without dilution, which ensures that the natural concentration and properties of the target are maintained. Less influence from the substrate is achieved compared with the spray methods based on porous absorbent materials, which results in a sensitivity enhancement of large molecule samples. It is demonstrated that the interlayer spray is applicable for the analysis of various compounds, including therapeutic drugs, peptides, and proteins. Good linearity can be obtained at a concentration as low as 50 ng/mL in the quantitative analysis for imatinib. We also show the ability to identify the chemical residuals on surfaces with high sensitivity by the "wipe-spray" method, which is useful for the fast screening of illicit substances. Interlayer spray working with mass spectrometry provides a promising method for direct analysis in an ambient environment.
引用
收藏
页码:5005 / 5012
页数:8
相关论文
共 50 条
  • [31] Cold-spray ionization mass spectrometry: principle and applications
    Yamaguchi, K
    JOURNAL OF MASS SPECTROMETRY, 2003, 38 (05): : 473 - 490
  • [32] Tissue-spray ionization mass spectrometry for raw herb analysis
    Chan, Sharon Lai-Fung
    Wong, Melody Yee-Man
    Tang, Ho-Wai
    Che, Chi-Ming
    Kwan-Ming Ng
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (19) : 2837 - 2843
  • [33] In Situ Separation and Analysis of Lipids by Paper Spray Ionization Mass Spectrometry
    Kal, Youngju
    Cha, Sangwon
    MOLECULES, 2021, 26 (01):
  • [34] Cold-spray ionization mass spectrometry
    Sei, Y
    Shikiii, K
    Sakamoto, S
    Kunimura, M
    Kobayashi, T
    Seki, H
    Tashiro, M
    Fujita, M
    Yamaguchi, K
    BUNSEKI KAGAKU, 2004, 53 (06) : 457 - 474
  • [35] Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry
    Yang, Qian
    Manicke, Nicholas E.
    Wang, He
    Petucci, Christopher
    Cooks, R. Graham
    Ouyang, Zheng
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (05) : 1389 - 1397
  • [36] Direct monitoring of drug degradation by easy ambient sonic-spray ionization mass spectrometry: the case of enalapril
    Amaral, Phellipe H.
    Fernandes, Raquel
    Eberlin, Marcos N.
    Hoeehr, Nelci F.
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (12): : 1269 - U27
  • [37] Rapid analysis of Aurantii Fructus Immaturus (Zhishi) using paper spray ionization mass spectrometry
    Liu, Xuemei
    Gu, Zhixin
    Guo, Yuan
    Liu, Jingjing
    Ma, Ming
    Chen, Bo
    Wang, Liping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 137 : 204 - 212
  • [38] A Polymer Coating Transfer Enrichment Method for Direct Mass Spectrometry Analysis of Lipids in Biofluid Samples
    Zhang, Wenpeng
    Chiang, Spencer
    Li, Zishuai
    Chen, Qinhua
    Xia, Yu
    Ouyang, Zheng
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2019, 58 (18) : 6064 - 6069
  • [39] RECENT DEVELOPMENTS IN SAMPLE IONIZATION INTERFACES USED IN MASS SPECTROMETRY
    Donegan, Michael
    Browning, Marc
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (16) : 2345 - 2363
  • [40] Biogenic aldehyde determination by reactive paper spray ionization mass spectrometry
    Bag, Soumabha
    Hendricks, P. I.
    Reynolds, J. C.
    Cooks, R. G.
    ANALYTICA CHIMICA ACTA, 2015, 860 : 37 - 42