Harmonization protocols for TSH immunoassays: a multicenter study in Italy

被引:19
作者
Clerico, Aldo [1 ]
Ripoli, Andrea [2 ,3 ]
Fortunato, Antonio [4 ,5 ]
Alfano, Antonio [6 ]
Carrozza, Cinzia [7 ]
Correale, Mario [8 ]
Dittadi, Ruggero [9 ]
Gessoni, Gianluca [10 ]
Migliardi, Marco [11 ]
Rizzardi, Sara [12 ]
Prontera, Concetta [2 ,3 ]
Masotti, Silvia [2 ,3 ]
Zucchelli, Giancarlo [13 ,14 ]
Guiotto, Cristina [11 ]
Iacovazzi, Palma Aurelia [8 ]
Iervasi, Giorgio [14 ]
机构
[1] Fdn CNR Toscana G Monasterio, Lab Cardiovasc Endocrinol & Cell Biol, Dept Lab Med, Scuola Super St Anna, Via Trieste 41, I-56126 Pisa, Italy
[2] Fdn CNR Reg Toscana Gabriele Monasteri, Pisa, Italy
[3] Scuola Super Sant Anna, Pisa, Italy
[4] Osped San Bortolo, Lab Chim Clin & Ematol, Vicenza, Italy
[5] ASUR Marche Area Vasta, UOC Patol Clin, Ascoli Piceno, Italy
[6] Hosp ASL TO4, Clin Pathol, Turin, Italy
[7] Univ Cattolica Sacro Cuore, UO Anal Ormonali & Biol Mol Clin, Policlin A Gemelli, Rome, Italy
[8] IRCCS De Bellis, Clin Pathol Unit, Bari, Italy
[9] ULSS 12 Veneziana, UOC Lab Anal, Dept Lab Med, Osped Angelo, Venice, Italy
[10] Osped Madonna Navicella, Serv Med Lab, Chioggia, Italy
[11] AO Ordine Mauriziano Torino, SC Lab Anal, Turin, Italy
[12] Azienda Sociosanit Territoriale Cremona, Cremona, Italy
[13] Inst Pisa, QualiMedLab, Pisa, Italy
[14] Inst Pisa, CNR Clin Physiol, Pisa, Italy
关键词
harmonization; immunoassay methods; quality control; quality specification; standardization; thyroid-stimulating hormone (TSH); THYROID-FUNCTION TESTS; IFCC WORKING GROUP; STANDARDIZATION; PART; ALGORITHMS; THYROXINE;
D O I
10.1515/cclm-2016-0899
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Systematic difference between thyroid-stimulating hormone (TSH) immunoassays may produce misleading interpretation when samples of the same patients are measured with different methods. The study aims were to evaluate whether systematic differences are present among TSH immunoassays, and whether it is possible to obtain a better harmonization among TSH methods using results obtained in external quality assessment (EQA) schemes. Methods: Seven Italian clinical laboratories measured TSH in 745 serum samples of healthy subjects and patients with thyroid disorders. These samples were also re-measured by two reference laboratories of the study with the six TSH immunoassays most popular in Italy after 2 months of storage at -80 degrees C. Moreover, these data were compared to 53,823 TSH measurements, obtained by laboratories participant to 2012-2015 EQA annual cycles in 72 quality control samples (TSH concentrations from about 0.1 mIU/L to 18.0mIU/L). TSH concentrations were recalibrated using a mathematical approach based on the principal component analysis (PCA). Results: Systematic differences were found between the most popular commercially available TSH immunoassays. TSH concentrations measured by the clinical laboratories were very closely correlated to those measured with the same method by reference laboratories after 2 months of storage at -80 degrees C. After recalibration using the PCA approach the variation of TSH values significantly decreased from a median pre-calibration value of 13.53% (10.79%-16.53%) to 9.63% (6.90%-13.21%) after recalibration. Conclusions: Our data suggest that EQA schemes are useful to improve harmonization among TSH immunoassays and also to produce some mathematical formulas, which can be used by clinicians to better compare TSH values measured with different methods.
引用
收藏
页码:1722 / 1733
页数:12
相关论文
共 29 条
[1]  
[Anonymous], EXPLORATORY FACTOR A
[2]  
[Anonymous], PRINCIPAL COMPONENT
[3]   A survey of cross-validation procedures for model selection [J].
Arlot, Sylvain ;
Celisse, Alain .
STATISTICS SURVEYS, 2010, 4 :40-79
[4]   Statistical methods for the analysis of high-throughput metabolomics data [J].
Bartel, Joerg ;
Krumsiek, Jan ;
Theis, Fabian J. .
COMPUTATIONAL AND STRUCTURAL BIOTECHNOLOGY JOURNAL, 2013, 4 (05)
[5]   Boosting algorithms: Regularization, prediction and model fitting [J].
Buehlmann, Peter ;
Hothorn, Torsten .
STATISTICAL SCIENCE, 2007, 22 (04) :477-505
[6]   NEURAL NETWORKS - A REVIEW FROM A STATISTICAL PERSPECTIVE [J].
CHENG, B ;
TITTERINGTON, DM .
STATISTICAL SCIENCE, 1994, 9 (01) :2-30
[7]   Pilot study on harmonization of cardiac troponin I immunoassays using patients and quality control plasma samples. On behalf of the Italian Section of the European Ligand Assay Society (ELAS) and of the Study Group on Cardiovascular Biomarkers of the Society Italiana di Biochimica Clinica (SIBioC) [J].
Clerico, Aldo ;
Ripoli, Andrea ;
Masotti, Silvia ;
Prontera, Concetta ;
Storti, Simona ;
Fortunato, Antonio ;
Buzzi, Paola ;
Casagranda, Ivo ;
Franzini, Maria ;
Ndreu, Rudina ;
Zucchelli, Gian Carlo ;
Zaninotto, Martina ;
Plebani, Mario .
CLINICA CHIMICA ACTA, 2016, 456 :42-48
[8]   Harmonization protocols for thyroid stimulating hormone (TSH) immunoassays: different approaches based on the consensus mean value [J].
Clerico, Aldo ;
Ripoli, Andrea ;
Zucchelli, Gian Carlo ;
Plebani, Mario .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (03) :377-382
[9]   Algorithms for Projection - Pursuit robust principal component analysis [J].
Croux, C. ;
Filzmoser, P. ;
Oliveira, M. R. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 87 (02) :218-225
[10]  
Gantzer Mary Lou, 2012, Clin Biochem Rev, V33, P95