Differential pulse voltammetry in analysis of disinfectants-2-mercaptobenzothiazole, 4-chloro-3-methylphenol, triclosan, chloramine-T

被引:13
作者
Baranowska, Irena [1 ]
Bijak, Katarzyna [1 ]
机构
[1] Silesian Tech Univ, Dept Analyt Chem, Fac Chem, PL-44100 Gliwice, Poland
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2010年 / 8卷 / 06期
关键词
Disinfectants; Voltammetry; Glassy carbon electrode; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL DETERMINATION; ACCUMULATION;
D O I
10.2478/s11532-010-0111-2
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of this work was to study the possibility of simultaneous voltammetric determination of some disinfectants used as components in cosmetic products. The examined compounds were: triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol), chloramine-T (N-chloro-p-toluenesulfonamide sodium salt), 4-chloro-3-methylphenol and 2-mercaptobenzothiazole. Measurements were performed using glassy carbon electrode immersed in Britton-Robinson buffers which acted as supporting electrolytes. The dependence of oxidation and reduction potentials on pH was examined using cyclic voltammetry. Britton-Robinson buffer of pH 9.9 was chosen for further studies to ensure the best separation of compounds. The resultant oxidation potentials indicate the possibility to simultaneously determine some of the disinfectants.. Oxidation reactions of mixtures containing two compounds (4-chloro-3-methylphenol and chloramine-T, 2-mercaptobenzothiazole and 4-chloro-3-methylphenol, 2-mercaptobenzothiazole and triclosan) were recorded as differential pulse voltammograms.
引用
收藏
页码:1266 / 1272
页数:7
相关论文
共 17 条
[1]   Electrostatic accumulation and determination of triclosan in ultrathin carbon nanoparticle composite film electrodes [J].
Amiri, Mandana ;
Shahrokhian, Saeed ;
Psillakis, Elefteria ;
Marken, Frank .
ANALYTICA CHIMICA ACTA, 2007, 593 (01) :117-122
[2]   Simultaneous Differential Pulse Voltammetric Determination of Sulfamethoxazole and Trimethoprim on a Boron-Doped Diamond Electrode [J].
Andrade, Leonardo S. ;
Rocha-Filho, Romeu C. ;
Cass, Quezia B. ;
Fatibello-Filho, Orlando .
ELECTROANALYSIS, 2009, 21 (13) :1475-1480
[3]   Thin-film modified electrodes with reconstituted cellulose-PDDAC films for the accumulation and detection of triclosan [J].
Bonne, Michael J. ;
Edler, Karen J. ;
Buchanan, J. Grant ;
Wolverson, Daniel ;
Psillakis, Elefteria ;
Helton, Matthew ;
Thielemans, Wim ;
Marken, Frank .
JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (07) :2660-2666
[4]  
CARVALHO RM, 2000, ANAL CHIM ACTA, V420, P109, DOI DOI 10.1016/S0003-2670(00)01012-6
[5]   Cathodic stripping voltammetric determination of 2-mercaptobenzothiazole using the catalytic cobalt peak [J].
Fogg, AG ;
Ismail, R ;
Ahmad, R ;
Banica, FG .
TALANTA, 1997, 44 (03) :491-495
[6]   Microwave activation of electrochemical processes: High temperature phenol and triclosan electro-oxidation at carbon and diamond electrodes [J].
Ghanem, Mohamed A. ;
Compton, Richard G. ;
Coles, Barry A. ;
Psillakis, Elefteria ;
Kulandainathan, M. Anbu ;
Marken, Frank .
ELECTROCHIMICA ACTA, 2007, 53 (03) :1092-1099
[7]   VOLTAMMETRIC DETERMINATION OF 4-CHLORO-3-METHYLPHENOL AT A GLASSY-CARBON ELECTRODE [J].
GUIJARRO, EC ;
YANEZSEDENO, P ;
CARRAZON, JMP ;
DIEZ, LMP .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (03) :193-196
[8]   Electrochemical reduction of 5-chloro-2-(2,4-dichlorophenoxy)phenol (triclosan) in dimethylformamide [J].
Knust, Kyle N. ;
Foley, Matthew P. ;
Mubarak, Mohammad S. ;
Skljarevski, Sonja ;
Raghavachari, Krishnan ;
Peters, Dennis G. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 638 (01) :100-108
[9]   SIMULTANEOUS DETERMINATION OF ASCORBIC-ACID, CAFFEINE AND PARACETAMOL IN DRUG FORMULATIONS BY DIFFERENTIAL-PULSE VOLTAMMETRY USING A GLASSY-CARBON ELECTRODE [J].
LAU, OW ;
LUK, SF ;
CHEUNG, YM .
ANALYST, 1989, 114 (09) :1047-1051
[10]   Development and characterization of an amperometric sensor for triclosan detection based on electropolymerized molecularly imprinted polymer [J].
Liu, Ying ;
Song, Qi-Jun ;
Wang, Li .
MICROCHEMICAL JOURNAL, 2009, 91 (02) :222-226