Fingerprinting of the Unsaponifiable Fraction of Vegetable Oils by Using Cryogenically-Modulated Comprehensive Two-Dimensional Gas Chromatography-High Resolution Time-of-Flight Mass Spectrometry

被引:13
作者
Aloisi, Ivan [1 ]
Zoccali, Mariosimone [2 ]
Dugo, Paola [1 ,3 ,4 ]
Tranchida, Peter Q. [1 ]
Mondello, Luigi [1 ,3 ,4 ,5 ]
机构
[1] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[2] Univ Messina, Phys Sci & Earth Sci, Dept Math & Computat Sci, Messina, Italy
[3] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Chromaleont Srl, Messina, Italy
[4] Univ Campus Biomed Rome, Unit Food Sci & Nutr, Dept Med, Rome, Italy
[5] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, BeSep Srl, Messina, Italy
关键词
Vegetable oils; Unsaponifiable fraction; Extra virgin olive oil; Comprehensive two-dimensional gas chromatography; High resolution time-of-flight mass spectrometry; GC;
D O I
10.1007/s12161-020-01773-9
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The present research is focused on the development of a cryogenically modulated (CM) comprehensive two-dimensional gas chromatography-high resolution time-of-flight mass spectrometry (GC x GC-HR ToFMS) method for the in-depth profiling of the unsaponifiable fraction of vegetable oils. Specifically, twelve vegetable oils (9 extra-virgin olive, soybean, peanut, and hazelnut oils) were subjected to analysis, with particular attention devoted to the higher molecular weight constituents (sterols, vitamin E, triterpenic alcohols). Peak assignment was carried out by using commercial unit-mass MS databases, accurate mass data, literature and on-line freely-available mass spectral information, as well as an in-lab-constructed HR ToFMS lipid database. The main objective of the work was to develop a method to define a well-characterized extra-virgin olive oil fingerprint, to be potentially exploited for vegetable oil differentiation. An additional objective of the investigation was to evaluate the performance of the HR ToFMS system (operated at a mass resolution of 25,000 FWHM) under the challenging analytical conditions of a CM GC x GC-based experiment. The HR ToFMS accurate-mass lipid database was (previously) constructed by acquiring, for the main part, the mass spectra of vegetable oil constituents, well-separated from both the matrix and column bleed background.
引用
收藏
页码:1523 / 1529
页数:7
相关论文
共 12 条
[1]   Separation of stigmasta-3,5-diene squalene isomers, and wax esters from olive oils by single high-performance liquid chromatography run [J].
Amelio, M ;
Rizzo, R ;
Varazini, F .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1998, 75 (04) :527-530
[2]  
Boskou D., 2006, Olive oil chemistry and technology, P41, DOI DOI 10.1016/B978-1-893997-88-2.50008-0
[3]   M Distinguishing the C3 VS SH4 Mass Split by Comprehensive Two-Dimensional Gas Chromatography-High Resolution Time-of-Flight Mass Spectrometry [J].
Byer, Jonathan D. ;
Siek, Kevin ;
Jobst, Karl .
ANALYTICAL CHEMISTRY, 2016, 88 (12) :6101-6104
[4]  
Frysinger GS, 1999, HRC-J HIGH RES CHROM, V22, P251
[5]   Gas chromatography coupled to high-resolution time-of-flight mass spectrometry to analyze trace-level organic compounds in the environment, food safety and toxicology [J].
Hernandez, Felix ;
Portoles, Tania ;
Pitarch, Elena ;
Lopez, Francisco J. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (02) :388-400
[6]   COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE [J].
LIU, ZY ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :227-231
[7]   Multidimensional gas chromatography [J].
Marriott, Philip J. ;
Chin, Sung-Tong ;
Maikhunthod, Bussayarat ;
Schmarr, Hans-Georg ;
Bieri, Stefan .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 34 :1-21
[8]  
Tranchida P. Q., 2014, LC GC N AM, V32, P24
[9]   Current state of comprehensive two-dimensional gas chromatography-mass spectrometry with focus on processes of ionization [J].
Tranchida, Peter Q. ;
Aloisi, Ivan ;
Giocastro, Barbara ;
Mondello, Luigi .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 105 :360-366
[10]   Flow-Modulated Comprehensive Two-Dimensional Gas Chromatography Combined with a High-Resolution Time-of-Flight Mass Spectrometer: A Proof-of-Principle Study [J].
Tranchida, Peter Q. ;
Salivo, Simona ;
Franchina, Flavio A. ;
Mondello, Luigi .
ANALYTICAL CHEMISTRY, 2015, 87 (05) :2925-2930