Experimental study on the design of orifice pulse tube refrigerator

被引:6
作者
Huang, BJ [1 ]
Yu, GJ [1 ]
机构
[1] Natl Taiwan Univ, Dept Mech Engn, Taipei 10764, Taiwan
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2001年 / 24卷 / 05期
关键词
cryorefrigerator; pulse tube; performance; parameter single stage system;
D O I
10.1016/S0140-7007(00)00038-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study on the design of a single-stage orifice pulse tube refrigerator (OPTR) was carried out. It was shown experimentally that there exists an optimum operating frequency which increases with decreasing pulse tube volume, For a fixed pulse tube volume, increasing the pulse tube diameter will improve the performance. The experimental results are used to derive a correlation for the performance of OPTR which correlates the net cooling capacity with the operating conditions and the dimensions of the OPTR. (C) 2001 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:400 / 408
页数:9
相关论文
共 14 条
[1]  
[Anonymous], 1990, Adv. Cryog. Eng.
[2]  
[Anonymous], ADV CRYOG ENG
[3]   EXPERIMENTAL-VERIFICATION OF AN ANALYTICAL MODEL FOR ORIFICE PULSE TUBE REFRIGERATION [J].
BAKS, MJA ;
HIRSCHBERG, A ;
VANDERCEELEN, BJ ;
GIJSMAN, HM .
CRYOGENICS, 1990, 30 (11) :947-951
[4]   EXPERIMENTAL-ANALYSIS OF DOUBLE-INLET PRINCIPLE IN PULSE TUBE REFRIGERATORS [J].
CAI, JH ;
ZHOU, Y ;
WANG, JJ ;
ZHU, WX .
CRYOGENICS, 1993, 33 (05) :522-525
[5]   EXPERIMENTAL-ANALYSIS OF THE MULTI-BYPASS PRINCIPLE IN PULSE TUBE REFRIGERATORS [J].
CAI, JH ;
WANG, JJ ;
ZHU, WX ;
ZHOU, Y .
CRYOGENICS, 1994, 34 (09) :713-715
[6]  
DAVID M, 1993, CRYOGENICS, V33, P54
[7]  
HARPOLE GM, 1991, P 6 INT CRYOC C PLYM, V1, P91
[8]   System design of orifice pulse-tube refrigerator using linear flow network analysis [J].
Huang, BJ ;
Chuang, MD .
CRYOGENICS, 1996, 36 (11) :889-902
[9]  
*IW CO, 1995, CAT PTRE CRYOM PULS
[10]   General pulse tube theory [J].
Kittel, P ;
Kashani, A ;
Lee, JM ;
Roach, PR .
CRYOGENICS, 1996, 36 (10) :849-857