Narrow-band imaging colonoscopy - a pilot feasibility study for the detection of polyps and correlation of surface patterns with polyp histologic diagnosis

被引:137
作者
Rastogi, Amit [1 ]
Bansal, Ajay [1 ]
Wani, Sachin [1 ]
Callahan, Peggy [1 ]
McGregor, Douglas H. [2 ]
Cherian, Rachel [2 ]
Sharma, Prateek [1 ]
机构
[1] Univ Kansas, Sch Med, Vet Affairs Med Ctr, Div Gastroenterol Hepatol, Kansas City, MO 64128 USA
[2] Univ Kansas, Sch Med, Vet Affairs Med Ctr, Dept Pathol, Kansas City, MO USA
关键词
D O I
10.1016/j.gie.2007.07.036
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Colonoscopy is the preferred screening method for colorectal cancer. However, it has a substantial miss rate for colon polyps, and several techniques have been attempted to improve this limitation. Narrow-band imaging (NBI) is a novel technology that enhances the visualization of surface mucosal and vascular patterns. Objective: The aim of this study was to determine the detection rate of additional polyps by NBI after removal of polyps visualized by standard white light colonoscopy (WLC) and to correlate the surface mucosal and vascular patterns with polyp histologic diagnosis. Design: This was a prospective pilot feasibility study. Setting: Kansas City Veterans Affairs Medical Center. Patients: Subjects referred for screening colonoscopy were prospectively enrolled. Methods: Subjects underwent colonoscopy after enrollment. After intubation of the cecum, colonic segments were sequentially examined, initially with WLC with removal of polyps followed by re-examination of the same segment with NBI. Additional polyps seen with NBI were photographed for their surface patterns and then removed. The total number of polyps visualized by WLC and NBI was calculated and the surface patterns were then correlated with polyp histologic features. Results: Forty patients were enrolled in the study, all men, 32 white. The mean age was 62 years. A total of 72 polyps were detected by WLC (43 tubular adenoma, 28 hyperplastic polyps), whereas NBI detected an additional 51 polyps, of which 29 were tubular adenomas and 22 were hyperplastic. Five different surface/vascular patterns were observed: fine capillary network with absent mucosal pattern, circular pattern with dots, round/oval pattern, tubular pattern, and gyrus pattern. The sensitivity, specificity, and overall accuracy of the first two patterns for hyperplastic polyps were 86%, 96%, and 92%, respectively, and of the latter three patterns for tubular adenomas were 96%, 86%, and 92%, respectively. Conclusions: This pilot study demonstrates the feasibility of polyp detection and histologic correlation with NBI. These findings need to be confirmed in future randomized controlled trials.
引用
收藏
页码:280 / 286
页数:7
相关论文
共 30 条
  • [21] Wide angle colonoscopy with a prototype instrument: Impact on miss rates and efficiency as determined by back-to-back colonoscopies
    Rex, DK
    Chadalawada, V
    Helper, DJ
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (09) : 2000 - 2005
  • [22] Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
    Rex, DK
    Cutler, CS
    Lemmel, GT
    Rahmani, EY
    Clark, DW
    Helper, DJ
    Lehman, GA
    Mark, DG
    [J]. GASTROENTEROLOGY, 1997, 112 (01) : 24 - 28
  • [23] Rex DK, 2006, REV GASTROENTEROL DI, V6, pS28
  • [24] Colorectal cancer in patients under close colonoscopic surveillance
    Robertson, DJ
    Greenberg, ER
    Beach, M
    Sandler, RS
    Ahnen, D
    Haile, RW
    Burke, CA
    Snover, DC
    Bresalier, RS
    McKeown-Eyssen, G
    Mandel, JS
    Bond, JH
    Van Stolk, RU
    Summers, RW
    Rothstein, R
    Church, TR
    Cole, BF
    Byers, T
    Mott, L
    Baron, JA
    [J]. GASTROENTEROLOGY, 2005, 129 (01) : 34 - 41
  • [25] Lack of effect of a low-fat, high-fiber diet on the recurrence of colorectal adenomas
    Schatzkin, A
    Lanza, E
    Corle, D
    Lance, P
    Iber, F
    Caan, B
    Shike, M
    Weissfeld, J
    Burt, R
    Cooper, MR
    Kikendall, JW
    Cahill, J
    Freedman, L
    Marshall, J
    Schoen, RE
    Slattery, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (16) : 1149 - 1155
  • [26] Risk of developing colorectal cancer following a negative colonoscopy examination - Evidence for a 10-year interval between colonoscopies
    Singh, Harminder
    Turner, Donna
    Xue, Lin
    Targownik, Laura E.
    Bernstein, Charles N.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (20): : 2366 - 2373
  • [27] Comparative study of conventional colonoscopy, chromoendoscopy, and narrow-band imaging systems in differential diagnosis of neoplastic and nonneoplastic colonic polyps
    Su, Ming-Yao
    Hsu, Chen-Ming
    Ho, Yu-Pin
    Chen, Pang-Chi
    Lin, Chun-Jung
    Chiu, Cheng-Tang
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (12) : 2711 - 2716
  • [28] Thiis-Evensen E, 1999, SCAND J GASTROENTERO, V34, P414
  • [29] Polyp miss rate determined by tandem colonoscopy: A systematic review
    van Rijn, JC
    Reitsma, JB
    Stoker, J
    Bossuyt, PM
    van Deventer, SJ
    Dekker, E
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (02) : 343 - 350
  • [30] PREVENTION OF COLORECTAL-CANCER BY COLONOSCOPIC POLYPECTOMY
    WINAWER, SJ
    ZAUBER, AG
    HO, MN
    OBRIEN, MJ
    GOTTLIEB, LS
    STERNBERG, SS
    WAYE, JD
    SCHAPIRO, M
    BOND, JH
    PANISH, JF
    ACKROYD, F
    SHIKE, M
    KURTZ, RC
    HORNSBYLEWIS, L
    GERDES, H
    STEWART, ET
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (27) : 1977 - 1981