Quantification of Alefacept, an immunosuppressive fusion protein in human plasma using a protein analogue internal standard, trypsin cleaved signature peptides and liquid chromatography tandem mass spectrometry

被引:18
作者
Halquist, Matthew S. [1 ]
Karnes, H. Thomas [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Pharmaceut, Richmond, VA 23298 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 11-12期
关键词
Signature peptides; LC-MS/MS; Biological fluids; Matrix effects; IMMUNOAFFINITY ENRICHMENT; MONITORING PHOSPHOLIPIDS; ABSOLUTE QUANTIFICATION; QUANTITATIVE-ANALYSIS; MULTIPLEXED ASSAYS; ABUNDANCE PROTEINS; SERUM; ANTIBODY; IMMUNOCAPTURE; EPIDEMIOLOGY;
D O I
10.1016/j.jchromb.2011.02.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative analysis of a therapeutic protein through use of surrogate proteotypic peptides was evaluated for the measurement of Amevive (Alefacept) in human plasma using liquid chromatography tandem mass spectrometry. Signature peptides were obtained through in silico and iterative tuning processes to represent Alefacept for quantification. Horse heart myoglobin was chosen as a protein analogue internal standard to compensate for errors associated with matrix effects and to track recovery throughout the entire sample pretreatment process. Samples were prepared for analysis by selective precipitation of the target proteins with pH controlled at 5.1 and heat denaturation at 45 degrees C followed by enzymatic digestion, dilution, and filtration. On-line extraction of the signature peptides was carried out using a Phenomenex Gemini C18 security guard column (4.0 mm x 2.0 mm) as a loading column and a Gemini C18 (100 mm x 2.1 I.D., particle size 5 mu m) as the analytical (eluting) column. Tandem mass spectrometric detection was performed on a hybrid triple quadrupole linear ion trap equipped with electrospray ionization to positively ionize signature peptides for Alefacept and myoglobin. The method was linear for Alefacept (protein) concentrations between 250 and 10,000 ng/mL. Precision and accuracy for inter-and intra-assay for the lower limit of quantification was less than 20% (16.2 and 10.3, respectively). The method was validated according to current FDA guidelines for bioanalytical method validation. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:789 / 798
页数:10
相关论文
共 40 条
[1]   Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry [J].
Abbatiello, Susan E. ;
Mani, D. R. ;
Keshishian, Hasmik ;
Carr, Steven A. .
CLINICAL CHEMISTRY, 2010, 56 (02) :291-305
[2]   Coupling immunoaffinity techniques with MS for quantitative analysis of low-abundance protein biomarkers [J].
Ackermann, Bradley L. ;
Berna, Michael J. .
EXPERT REVIEW OF PROTEOMICS, 2007, 4 (02) :175-186
[3]   Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma [J].
Addona, Terri A. ;
Abbatiello, Susan E. ;
Schilling, Birgit ;
Skates, Steven J. ;
Mani, D. R. ;
Bunk, David M. ;
Spiegelman, Clifford H. ;
Zimmerman, Lisa J. ;
Ham, Amy-Joan L. ;
Keshishian, Hasmik ;
Hall, Steven C. ;
Allen, Simon ;
Blackman, Ronald K. ;
Borchers, Christoph H. ;
Buck, Charles ;
Cardasis, Helene L. ;
Cusack, Michael P. ;
Dodder, Nathan G. ;
Gibson, Bradford W. ;
Held, Jason M. ;
Hiltke, Tara ;
Jackson, Angela ;
Johansen, Eric B. ;
Kinsinger, Christopher R. ;
Li, Jing ;
Mesri, Mehdi ;
Neubert, Thomas A. ;
Niles, Richard K. ;
Pulsipher, Trenton C. ;
Ransohoff, David ;
Rodriguez, Henry ;
Rudnick, Paul A. ;
Smith, Derek ;
Tabb, David L. ;
Tegeler, Tony J. ;
Variyath, Asokan M. ;
Vega-Montoto, Lorenzo J. ;
Wahlander, Asa ;
Waldemarson, Sofia ;
Wang, Mu ;
Whiteaker, Jeffrey R. ;
Zhao, Lei ;
Anderson, N. Leigh ;
Fisher, Susan J. ;
Liebler, Daniel C. ;
Paulovich, Amanda G. ;
Regnier, Fred E. ;
Tempst, Paul ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2009, 27 (07) :633-U85
[4]   Quantitative Analysis of an Aberrant Glycoform of TIMP1 from Colon Cancer Serum by L-PHA-Enrichment and SISCAPA with MRM Mass Spectrometry [J].
Ahn, Yeong Hee ;
Lee, Ji Yeon ;
Lee, Ju Yeon ;
Kim, Yong-Sam ;
Ko, Jeong Heon ;
Yoo, Jong Shin .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (09) :4216-4224
[5]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[6]   Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA) [J].
Anderson, NL ;
Anderson, NG ;
Haines, LR ;
Hardie, DB ;
Olafson, RW ;
Pearson, TW .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (02) :235-244
[7]   Quantification of NTproBNP in rat serum using immunciprecipitation and LC/MS/MS: a biomarker of drug-induced cardiac hypertrophy [J].
Berna, Michael ;
Ott, Lee ;
Engle, Steve ;
Watson, David ;
Solter, Philip ;
Ackermann, Bradley .
ANALYTICAL CHEMISTRY, 2008, 80 (03) :561-566
[8]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[9]  
2-0
[10]   Isotope-labeled protein standards [J].
Brun, Virginie ;
Dupuis, Alain ;
Adrait, Annie ;
Marcellin, Marlene ;
Thomas, Damien ;
Court, Magali ;
Vandenesch, Francois ;
Garin, Jerome .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (12) :2139-2149