MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T

被引:27
|
作者
Crombe, A. [1 ]
Saranathan, M. [3 ]
Ruet, A. [2 ,4 ]
Durieux, M. [1 ]
de Roquefeuil, E. [1 ]
Ouallet, J. C. [2 ]
Brochet, B. [2 ,4 ]
Dousset, V. [1 ,4 ]
Tourdias, T. [1 ,4 ]
机构
[1] CHU Bordeaux, Serv Neuroimagerie Diagnost & Therapeut, F-33076 Bordeaux, France
[2] CHU Bordeaux, Pole Neurosci Clin, F-33076 Bordeaux, France
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Univ Bordeaux, INSERM, U862, Neuroctr Magendie, Bordeaux, France
关键词
HIGH-FIELD MRI; MULTIPLE-SCLEROSIS; CONTRAST ENHANCEMENT; MP-RAGE; BRAIN; SEQUENCES; RECOMMENDATIONS; STRENGTH; SINGLE; SENSITIVITY;
D O I
10.3174/ajnr.A4152
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI or the detection of gadolinium-enhancing MS lesions. MATERIALS AND METHODS: Fifty-eight patients with MS were prospectively imaged at 31 by using both 2D-spin-echo and 3D-gradient recalled-echo T1WI in random order after the injection of gadolinium. Blinded and independent evaluation was performed by a junior and a senior reader to count gadolinium-enhancing lesions and to characterize their location, size, pattern of enhancement, and the relative contrast between enhancing lesions and the adjacent white matter. Finally, the SNR and relative contrast of gadolinium-enhancing lesions were computed for both sequences by using simulations. RESULTS: Significantly more gadolinium-enhancing lesions were reported on 3D-gradient recalled-echo than on 2D-spin-echo (n = 59 versus n = 30 for the junior reader, P = .021: n = 77 versus n = 61 for the senior reader, P = .017). The difference between the 2 readers was significant on 2D-spin-echo (P = .044), for which images were less reproducible (K = 0.51) than for 3D-gradient recalled-echo (rc = 0.65). Further comparisons showed that there were statistically more small lesions (<5 mm) on 3D-gradient recalled-echo than on 2D-spin-echo (P = .04), while other features were similar. Theoretic results from simulations predicted SNR and lesion contrast for 3D-gradient recalled-echo to be better than for 2D-spin-echo for visualization of small enhancing lesions and were, therefore, consistent with clinical observations. CONCLUSIONS: At 31, 3D-gradient recalled-echo provides a higher detection rate of gadolinium-enhancing lesions, especially those with smaller size, with a better reproducibility; this finding suggests using 3D-gradient recalled-echo to detect MS activity, with potential impact in initiation, monitoring, and optimization of therapy.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [41] A 3D T1-WEIGHTED GRADIENT-ECHO SEQUENCE FOR ROUTINE USE IN 3D RADIOSURGICAL TREATMENT PLANNING OF BRAIN METASTASES - FIRST CLINICAL-RESULTS
    HAWIGHORST, H
    SCHAD, LR
    GADEMANN, G
    BLUML, S
    KNOPP, MV
    WENZ, F
    VANKAICK, G
    EUROPEAN RADIOLOGY, 1995, 5 (01) : 19 - 25
  • [42] Articular cartilage grading of the knee: diagnostic performance of fat-suppressed 3D volume isotropic turbo spin-echo acquisition (VISTA) compared with 3D T1 high-resolution isovolumetric examination (THRIVE)
    Lee, Young Han
    Hahn, Seok
    Lim, Daekeon
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2017, 58 (02) : 190 - 196
  • [43] T2-weighted turbo spin-echo magnetic resonance imaging of canine brain anatomy at 1.5T, 3T, and 7T field strengths
    Jacqmot, Olivier
    Van Thielen, Bert
    Hespel, Adrien-Maxence
    Luijten, Peter R.
    de Mey, Johan
    Van Binst, Anne
    Provyn, Steven
    Tresignie, Jonathan
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2022, 305 (01): : 222 - 233
  • [44] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [45] 3D T1-weighted turbo spin echo contrast-enhanced MRI at 1.5 T for frameless brain metastases radiotherapy
    Yuan, Jing
    Law, Stephen C. K.
    Wong, Ka Kin
    Lo, Gladys G.
    Kam, Michael K. M.
    Kwan, Wing Hong
    Xue, Cindy
    Wong, Oi Lei
    Yu, Siu Ki
    Cheung, Kin Yin
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2022, 148 (07) : 1749 - 1759
  • [46] 3D-Double-Inversion Recovery detects perilesional gliosis better than 3D-FLAIR and postcontrast T1 imaging in calcified neurocysticercosis
    Saini, Jitender
    Gupta, Pradeep Kumar
    Gupta, Praveen
    Yadav, Ravi
    Yadav, Nishtha
    Gupta, Rakesh Kumar
    NEUROLOGY INDIA, 2019, 67 (01) : 136 - 141
  • [47] Clinical Value of 3D T2*-weighted Imaging with Multi-echo Acquisition: Comparison with Conventional 2D T2*-weighted Imaging and 3D Phase-sensitive MR Imaging
    Kunimatsu, Akira
    Suzuki, Yuichi
    Hagiwara, Kazuchika
    Sasaki, Hiroki
    Mori, Harushi
    Katsura, Masaki
    Ohtomo, Kuni
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (03) : 205 - 211
  • [48] Comparison of Contrast-Enhanced 3D Imaging with 2D Imaging in the Evaluation of Perianal Fistula at 3T: A Prospective Observational Study
    Kv, Abdulla
    Arunachalam, Venkatesh Kasi
    Sherene, Haleema
    Ethiraju, Vijayakumaran
    Ranganathan, Rupa
    Sm, Gowtham
    Rajasekaran, Sriman
    Mehta, Pankaj
    Cherian, Mathew
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (01) : 95 - 102
  • [49] Evaluation of Selective Bundle Injury to the Anterior Cruciate Ligament: T2-Weighted Fast Spin-Echo 3-T MRI With Reformatted 3D Oblique Isotropic (VISTA) Versus 2D Technique
    Lee, Jung Eun
    Park, Hee Jin
    Lee, So Yeon
    Ahn, Jin Hwan
    Park, Jai Hyung
    Park, Ji Yeon
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (05) : W308 - W316
  • [50] MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T
    Bian, Wei
    Kerr, Adam B.
    Tranvinh, Eric
    Parivash, Sherveen
    Zahneisen, Benjamin
    Han, May H.
    Lock, Christopher B.
    Goubran, Maged
    Zhu, Kongrong
    Rutt, Brian K.
    Zeineh, Michael M.
    PLOS ONE, 2019, 14 (07):