MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T

被引:27
|
作者
Crombe, A. [1 ]
Saranathan, M. [3 ]
Ruet, A. [2 ,4 ]
Durieux, M. [1 ]
de Roquefeuil, E. [1 ]
Ouallet, J. C. [2 ]
Brochet, B. [2 ,4 ]
Dousset, V. [1 ,4 ]
Tourdias, T. [1 ,4 ]
机构
[1] CHU Bordeaux, Serv Neuroimagerie Diagnost & Therapeut, F-33076 Bordeaux, France
[2] CHU Bordeaux, Pole Neurosci Clin, F-33076 Bordeaux, France
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Univ Bordeaux, INSERM, U862, Neuroctr Magendie, Bordeaux, France
关键词
HIGH-FIELD MRI; MULTIPLE-SCLEROSIS; CONTRAST ENHANCEMENT; MP-RAGE; BRAIN; SEQUENCES; RECOMMENDATIONS; STRENGTH; SINGLE; SENSITIVITY;
D O I
10.3174/ajnr.A4152
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI or the detection of gadolinium-enhancing MS lesions. MATERIALS AND METHODS: Fifty-eight patients with MS were prospectively imaged at 31 by using both 2D-spin-echo and 3D-gradient recalled-echo T1WI in random order after the injection of gadolinium. Blinded and independent evaluation was performed by a junior and a senior reader to count gadolinium-enhancing lesions and to characterize their location, size, pattern of enhancement, and the relative contrast between enhancing lesions and the adjacent white matter. Finally, the SNR and relative contrast of gadolinium-enhancing lesions were computed for both sequences by using simulations. RESULTS: Significantly more gadolinium-enhancing lesions were reported on 3D-gradient recalled-echo than on 2D-spin-echo (n = 59 versus n = 30 for the junior reader, P = .021: n = 77 versus n = 61 for the senior reader, P = .017). The difference between the 2 readers was significant on 2D-spin-echo (P = .044), for which images were less reproducible (K = 0.51) than for 3D-gradient recalled-echo (rc = 0.65). Further comparisons showed that there were statistically more small lesions (<5 mm) on 3D-gradient recalled-echo than on 2D-spin-echo (P = .04), while other features were similar. Theoretic results from simulations predicted SNR and lesion contrast for 3D-gradient recalled-echo to be better than for 2D-spin-echo for visualization of small enhancing lesions and were, therefore, consistent with clinical observations. CONCLUSIONS: At 31, 3D-gradient recalled-echo provides a higher detection rate of gadolinium-enhancing lesions, especially those with smaller size, with a better reproducibility; this finding suggests using 3D-gradient recalled-echo to detect MS activity, with potential impact in initiation, monitoring, and optimization of therapy.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [21] Optimization of workflow for detection of brain metastases at 3T: is a black-blood MTC prepared 3D T1 used alone robust enough to replace the combination of conventional 3D T1 and the black-blood 3D T1 MTC?
    Chkili, Sophia
    Lefebvre, Yolene
    Chao, Shih-Li
    Bali, Maria Antonietta
    Lemort, Marc
    Coquelet, Nicolas
    NEURORADIOLOGY, 2023, 65 (07) : 1133 - 1141
  • [22] Optimization of workflow for detection of brain metastases at 3T: is a black-blood MTC prepared 3D T1 used alone robust enough to replace the combination of conventional 3D T1 and the black-blood 3D T1 MTC?
    Sophia Chkili
    Yolène Lefebvre
    Shih-Li Chao
    Maria Antonietta Bali
    Marc Lemort
    Nicolas Coquelet
    Neuroradiology, 2023, 65 : 1133 - 1141
  • [23] Single-Slab 3D Fast Spin Echo Imaging: T1-Contrast Perspective
    Park, Jaeseok
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2023, 27 (03) : 121 - 132
  • [24] 3D T2-Weighted Spin Echo Imaging in the Breast
    Moran, Catherine J.
    Hargreaves, Brian A.
    Saranathan, Manojkumar
    Lipson, Jafi A.
    Kao, Jennifer
    Ikeda, Debra M.
    Daniel, Bruce L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 332 - 338
  • [25] Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo
    Sanchez, Felipe
    Tyrrell, Pascal N.
    Cheung, Patrick
    Heyn, Chinthaka
    Graham, Simon
    Poon, Ian
    Ung, Yee
    Louie, Alexander
    Tsao, May
    Oikonomou, Anastasia
    CANCER IMAGING, 2023, 23 (01)
  • [26] Improved Signal Spoiling in Fast Radial Gradient-Echo Imaging: Applied to Accurate T1 Mapping and Flip Angle Correction
    Lin, Wei
    Song, Hee Kwon
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) : 1185 - 1194
  • [27] Comparison of 3D multi-echo gradient-echo and 2D T2*MR sequences for the detection of arterial thrombus in patients with acute stroke
    Hodel, Jerome
    Leclerc, Xavier
    Khaled, Wassef
    Tamazyan, Ruben
    Rodallec, Mathieu
    Gerber, Sophie
    Blanc, Raphael
    Benadjaoud, Mohamed
    Lambert, Oriane
    Rabrait, Cecile
    Zuber, Mathieu
    Rahmouni, Alain
    Zins, Marc
    EUROPEAN RADIOLOGY, 2014, 24 (03) : 762 - 769
  • [28] Knee Derangements: Comparison of Isotropic 3D Fast Spin-Echo, Isotropic 3D Balanced Fast Field-Echo, and Conventional 2D Fast Spin-Echo MR Imaging
    Jung, Jin Young
    Yoon, Young Cheol
    Kim, Hye Rin
    Choe, Bong-Keun
    Wang, Joon Ho
    Jung, Jee Young
    RADIOLOGY, 2013, 268 (03) : 802 - 813
  • [29] THEORETICAL-ANALYSIS OF GADOPENTETATE DIMEGLUMINE ENHANCEMENT IN T1-WEIGHTED IMAGING OF THE BRAIN - COMPARISON OF 2-DIMENSIONAL SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO SEQUENCES
    MUGLER, JP
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 761 - 769
  • [30] Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping
    Wu, Lin
    Carchi, Chris
    Michaeli, Shalom
    Mangia, Silvia
    Idiyatullin, Djaudat
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (01) : 149 - 161