MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T

被引:27
|
作者
Crombe, A. [1 ]
Saranathan, M. [3 ]
Ruet, A. [2 ,4 ]
Durieux, M. [1 ]
de Roquefeuil, E. [1 ]
Ouallet, J. C. [2 ]
Brochet, B. [2 ,4 ]
Dousset, V. [1 ,4 ]
Tourdias, T. [1 ,4 ]
机构
[1] CHU Bordeaux, Serv Neuroimagerie Diagnost & Therapeut, F-33076 Bordeaux, France
[2] CHU Bordeaux, Pole Neurosci Clin, F-33076 Bordeaux, France
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Univ Bordeaux, INSERM, U862, Neuroctr Magendie, Bordeaux, France
关键词
HIGH-FIELD MRI; MULTIPLE-SCLEROSIS; CONTRAST ENHANCEMENT; MP-RAGE; BRAIN; SEQUENCES; RECOMMENDATIONS; STRENGTH; SINGLE; SENSITIVITY;
D O I
10.3174/ajnr.A4152
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI or the detection of gadolinium-enhancing MS lesions. MATERIALS AND METHODS: Fifty-eight patients with MS were prospectively imaged at 31 by using both 2D-spin-echo and 3D-gradient recalled-echo T1WI in random order after the injection of gadolinium. Blinded and independent evaluation was performed by a junior and a senior reader to count gadolinium-enhancing lesions and to characterize their location, size, pattern of enhancement, and the relative contrast between enhancing lesions and the adjacent white matter. Finally, the SNR and relative contrast of gadolinium-enhancing lesions were computed for both sequences by using simulations. RESULTS: Significantly more gadolinium-enhancing lesions were reported on 3D-gradient recalled-echo than on 2D-spin-echo (n = 59 versus n = 30 for the junior reader, P = .021: n = 77 versus n = 61 for the senior reader, P = .017). The difference between the 2 readers was significant on 2D-spin-echo (P = .044), for which images were less reproducible (K = 0.51) than for 3D-gradient recalled-echo (rc = 0.65). Further comparisons showed that there were statistically more small lesions (<5 mm) on 3D-gradient recalled-echo than on 2D-spin-echo (P = .04), while other features were similar. Theoretic results from simulations predicted SNR and lesion contrast for 3D-gradient recalled-echo to be better than for 2D-spin-echo for visualization of small enhancing lesions and were, therefore, consistent with clinical observations. CONCLUSIONS: At 31, 3D-gradient recalled-echo provides a higher detection rate of gadolinium-enhancing lesions, especially those with smaller size, with a better reproducibility; this finding suggests using 3D-gradient recalled-echo to detect MS activity, with potential impact in initiation, monitoring, and optimization of therapy.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [1] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    Aymerich, F. X.
    Auger, C.
    Alcaide-Leon, P.
    Pareto, D.
    Huerga, E.
    Corral, J. F.
    Mitjana, R.
    Sastre-Garriga, J.
    Montalban, X.
    Rovira, A.
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1361 - 1368
  • [2] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    F. X. Aymerich
    C. Auger
    P. Alcaide-Leon
    D. Pareto
    E. Huerga
    J. F. Corral
    R. Mitjana
    J. Sastre-Garriga
    X. Montalban
    A. Rovira
    European Radiology, 2017, 27 : 1361 - 1368
  • [3] Diagnostic Utility of 3D Gradient-Echo MR Imaging Sequences through the Filum Compared with Spin-Echo T1 in Children with Concern for Tethered Cord
    Rafiee, F.
    Mehan, W. A.
    Rincon, S.
    Rohatgi, S.
    Rapalino, O.
    Buch, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (03) : 323 - 327
  • [4] T1-weighted MR imaging of glioma at 3T: a comparative study of 3D MPRAGE vs. conventional 2D spin-echo imaging
    Dodo, Toshiki
    Okada, Tomohisa
    Yamamoto, Akira
    Kanagaki, Mitsunori
    Fushimi, Yasutaka
    Okada, Tsutomu
    Sakata, Akihiko
    Arakawa, Yoshiki
    Miyamoto, Susumu
    Togashi, Kaori
    CLINICAL IMAGING, 2016, 40 (06) : 1257 - 1261
  • [5] Improvement of the Diagnostic Performance of Facial Neuritis Using Contrast-Enhanced 3D T1 Black-Blood Imaging: Comparison with Contrast-Enhanced 3D T1-Spoiled Gradient-Echo Imaging
    Lee, Seun-Ah
    Jo, Sang-Won
    Chang, Suk-Ki
    Kwon, Ki-Han
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [6] MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo
    Dupuy, Sheena L.
    Tauhid, Shahamat
    Kim, Gloria
    Chu, Renxin
    Tummala, Subhash
    Hurwitz, Shelley
    Bakshi, Rohit
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1564 - 1568
  • [7] Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T
    Ozturk, Arzu
    Aygun, Nafi
    Smith, Seth A.
    Caffo, Brian
    Calabresi, Peter A.
    Reich, Daniel S.
    NEURORADIOLOGY, 2013, 55 (04) : 431 - 439
  • [8] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424
  • [9] Gadolinium-Enhanced Three-Dimensional Magnetization-Prepared Rapid Gradient-Echo (3D MP-RAGE) Imaging is Superior to Spin-Echo Imaging in Delineating Brain Metastases
    Takeda, T.
    Takeda, A.
    Nagaoka, T.
    Kunieda, E.
    Takemasa, K.
    Watanabe, M.
    Hatou, T.
    Oguro, S.
    Katayama, M.
    ACTA RADIOLOGICA, 2008, 49 (10) : 1167 - 1173
  • [10] INTRACRANIAL LESION ENHANCEMENT WITH GADOLINIUM - T1-WEIGHTED SPIN-ECHO VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM GRADIENT-ECHO MR IMAGING
    MIROWITZ, SA
    RADIOLOGY, 1992, 185 (02) : 529 - 534