Slowing the Increase in the Population Dose Resulting from CT Scans

被引:111
作者
Brenner, D. J. [1 ]
机构
[1] Columbia Univ, Ctr Radiol Res, Med Ctr, New York, NY 10032 USA
关键词
RADIOLOGY APPROPRIATENESS CRITERIA; MULTIPLE IMAGING TECHNIQUES; TRAUMA PRACTICE GUIDELINES; CERVICAL-SPINE EVALUATION; ATOMIC-BOMB SURVIVORS; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CANCER-RISKS; INTERNATIONAL SURVEY; EASTERN ASSOCIATION;
D O I
10.1667/RR1859.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The annual number of CT scans in the U.S. is now over 70 million. The concern is that organ doses from CT are typically far larger than those from conventional X-ray examinations, and there is epidemiological evidence of a small but significant increased cancer risk at typical CT doses. Because CT is a superb diagnostic tool and because individual CT risks are small, when a CT scan is clinically indicated, the CT benefit/risk balance is by far in the patient's favor. Nevertheless, CT should operate under the ALARA (As Low As Reasonably Achievable) principle, and opportunities exist to reduce the significant population dose associated with CT without compromising patient care. The first opportunity is to reduce the dose per scan, and improved technology has much potential here. The second opportunity is selective replacement of CT with other modalities, such as for many head and spinal examinations (with MRI), and for diagnosing appendicitis (selective use of ultrasound + CT). Finally, a fraction of CT scans could be avoided entirely, as indicated by CT decision rules: Clinical decision rules for CT use represent a powerful approach for slowing down the increase in CT use, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they are potentially not clinically helpful. In the U.S. and potentially elsewhere, legislative approaches are a possible option, to improve quality control and reduce clinically unneeded CT use, and it is also possible that upcoming changes in heath care economics will tend to slow the increase in such CT use. (C) 2010 by Radiation Research Society
引用
收藏
页码:809 / 815
页数:7
相关论文
共 63 条
[1]   Role of a quantitative D-dimer assay in determining the need for CT angiography of acute pulmonary embolism [J].
Abcarian, PW ;
Sweet, JD ;
Watabe, JT ;
Yoon, HC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (06) :1377-1381
[2]  
Amis E Stephen Jr, 2007, J Am Coll Radiol, V4, P272, DOI 10.1016/j.jacr.2007.03.002
[3]  
[Anonymous], 2006, Health risks from exposure to low levels of ionizing radiation BEIR VII, Phase 2
[4]   Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists [J].
Arch, Michael E. ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) :611-617
[5]   Do Clinicians Use the American College of Radiology Appropriateness Criteria in the Management of Their Patients? [J].
Bautista, Andre B. ;
Burgos, Anthony ;
Nickel, Barbara J. ;
Yoon, John J. ;
Tilara, Amish A. ;
Amorosa, Judith K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) :1581-1585
[6]  
Blachar Arye, 2006, J Am Coll Radiol, V3, P851, DOI 10.1016/j.jacr.2006.04.005
[7]   Computed tomography screening for lung cancer - Review of screening principles and update on current status [J].
Black, William C. .
CANCER, 2007, 110 (11) :2370-2384
[8]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[9]   Radiation Exposure From Medical Imaging Time to Regulate? [J].
Brenner, David J. ;
Hricak, Hedvig .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 304 (02) :208-209
[10]   Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006 [J].
Broder J. ;
Fordham L.A. ;
Warshauer D.M. .
Emergency Radiology, 2007, 14 (4) :227-232