Impact of the Lok-bar for High-precision Radiotherapy with Tomotherapy

被引:2
作者
Hirata, Makoto [1 ]
Monzen, Hajime [1 ]
Tamura, Mikoto [1 ,2 ]
Kubo, Kazuki [1 ,3 ]
Matsumoto, Kenji [1 ,2 ]
Hanaoka, Kohei [1 ,2 ]
Okumura, Masahiko [2 ]
Nishimura, Yasumasa [4 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Ohno Higashi, Osakasayama, Osaka 5898511, Japan
[2] Kindai Univ Hosp, Dept Cent Radiol, Osaka, Japan
[3] Tane Gen Hosp, Dept Radiat Oncol, Osaka, Japan
[4] Kindai Univ, Fac Med, Dept Radiat Oncol, Osaka, Japan
关键词
Artifacts; immobilizer; lok-bar; tomotherapy; HELICAL TOMOTHERAPY; RADIATION-THERAPY; IRRADIATION; ABSORPTION;
D O I
10.21873/anticanres.12515
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: Patient immobilization systems are used to establish a reproducible patient position relative to the couch. In this study, the impact of conventional lokbars for CT-simulation (CIVCO-bar) and treatment (iBEAMbar) were compared with a novel lok-bar (mHM-bar) in tomotherapy. Materials and Methods: Verification was obtained as follows: i. artifacts in CT images; ii. dose attenuation rate of lok-bar, compared to without lok-bar; and iii. dose differences between the calculated and measured absorbed doses. Results: With the CIVCO-bar, there were obvious metal artifacts, while there were nearly no artifacts with the mHM-bar. The mean dose attenuation rates with the mHM-bar and iBEAM-bar were 1.31% and 2.28%, and the mean dose difference was 1.55% and 1.66% for mHM-bar and iBEAM-bar. Conclusion: Using the mHM-bar reduced artifacts on the CT image and improved dose attenuation are obtained. The lok-bar needs to be inserted as a structure set in treatment planning with tomotherapy.
引用
收藏
页码:2733 / 2738
页数:6
相关论文
共 50 条
[31]   Comparison of Dosimetric Gains Provided by Intensity-Modulated Radiotherapy, Volume-Modulated Arc Therapy, and Helical Tomotherapy for High-Grade Glioma [J].
Liu, Pei ;
Liu, Gui ;
Wang, Guihua ;
Zhou, Weibing ;
Sun, Yangqing ;
Chen, Wen ;
Zeng, Qian ;
Hong, Jidong ;
Xie, Qiongxuan ;
Ou, Ludi ;
Wei, Rui .
BIOMED RESEARCH INTERNATIONAL, 2020, 2020
[32]   High-Precision Two-Dimensional Atom Localization in a Cascade-Type Atomic System [J].
Chen Jing-Dong ;
Fang Yu-Hong ;
Zhang Ting .
CHINESE PHYSICS LETTERS, 2014, 31 (10)
[33]   High-precision characterization of individual E. coli cell morphology by scanning flow cytometry [J].
Konokhova, Anastasiya I. ;
Gelash, Andrey A. ;
Yurkin, Maxim A. ;
Chernyshev, Andrey V. ;
Maltsev, Valeri P. .
CYTOMETRY PART A, 2013, 83A (06) :568-575
[34]   High-precision Q modeling and Q migration technology and its applications in loess plateau regions [J].
Xu, Wei ;
Liu, Hong-Xing ;
Mi, Hong-Gang ;
Zhang, Bing ;
Guo, Jun-Chao ;
Ge, Yong ;
You, Jun .
APPLIED GEOPHYSICS, 2024, 21 (04) :835-847
[35]   Three-dimensional atom localization with high-precision and high-resolution via a microwave field in an atomic system [J].
Liu, Jiayu ;
Wang, Haihua ;
Wang, Lei ;
Wang, Lin ;
Liu, Mingdong ;
Li, Aijun .
LASER PHYSICS, 2021, 31 (10)
[36]   High-dose Radiotherapy Using Helical Tomotherapy for Vertebral Metastasis: Early Clinical Outcomes and Cord Dose Specification [J].
Lee, Dong Soo ;
Kwak, Yoo Kang ;
Jeong, Song Mi ;
Song, Jin Ho ;
Kang, Young Nam ;
Lee, Sang Nam ;
Jang, Hong Seok ;
Kim, Yeon Sil ;
Yoon, Sei Chul ;
Choi, Byung Ock .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2013, 43 (06) :646-653
[37]   Comparison of helical tomotherapy with multi-field intensity-modulated radiotherapy treatment plans using simultaneous integrated boost in high-risk prostate cancer [J].
Basaran, Hamit ;
Karaca, Sibel ;
Koca, Timur ;
Gundogdu, Yasemin Ors .
POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (02) :143-149
[38]   From technological advances to biological understanding: The main steps toward high-precision RT in breast cancer [J].
Leonardi, Maria Cristina ;
Ricotti, Rosalinda ;
Dicuonzo, Samantha ;
Cattani, Federica ;
Morra, Anna ;
Dell'Acqua, Veronica ;
Orecchia, Roberto ;
Jereczek-Fossa, Barbara Alicja .
BREAST, 2016, 29 :213-222
[39]   High-precision CO2 isotopologue spectrometer with a difference-frequency-generation laser source [J].
Richter, Dirk ;
Wert, Bryan P. ;
Fried, Alan ;
Weibring, Petter ;
Walega, James G. ;
White, James W. C. ;
Vaughn, Bruce H. ;
Tittel, Frank K. .
OPTICS LETTERS, 2009, 34 (02) :172-174
[40]   Empirical planning target volume modeling for high precision MRI guided intracranial radiotherapy [J].
Stewart, James ;
Sahgal, Arjun ;
Zadeh, Mahtab M. ;
Moazen, Bahareh ;
Maralani, Pejman Jabehdar ;
Breen, Stephen ;
Lau, Angus ;
Binda, Shawn ;
Keller, Brian ;
Husain, Zain ;
Myrehaug, Sten ;
Detsky, Jay ;
Soliman, Hany ;
Tseng, Chia-Lin ;
Ruschin, Mark .
CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 39