Photon Counting CT of the liver with dual-contrast enhancement

被引:6
|
作者
Muenzel, Daniela [1 ]
Proksa, Roland [2 ]
Daerr, Heiner [2 ]
Fingerle, Alexander A. [1 ]
Pfeiffer, Franz [1 ,3 ,4 ]
Rummeny, Ernst J. [1 ]
Noel, Peter B. [1 ,3 ,4 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Diagnost & Intervent Radiol, D-80290 Munich, Germany
[2] Philips Res, Res Labs, Hamburg, Germany
[3] Tech Univ Munich, Chair Biomed Phys, Garching, Germany
[4] Tech Univ Munich, Dept Phys, Inst Med Engn, Garching, Germany
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
Photon Counting CT; Liver Imaging; Dual Contrast; Material Decomposition; HEPATOCELLULAR-CARCINOMA; PHASES; METASTASES;
D O I
10.1117/12.2216391
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The diagnostic quality of photon counting computed tomography (PCCT) is one the unexplored areas in medical imaging; at the same time, it seems to offer the opportunity as a fast and highly sensitive diagnostic tool. Today, conventional computed tomography (CT) is the standard imaging technique for diagnostic evaluation of the parenchyma of the liver. However, considerations on radiation dose are still an important factor in CT liver imaging, especially with regard to multi-phase contrast enhanced CT. In this work we report on a feasibility study for multi-contrast PCCT for simultaneous liver imaging at different contrast phases. PCCT images of the liver were simulated for a contrast-enhanced examination performed with two different contrast agents (CA), iodine (CA 1) and gadolinium (CA 2). PCCT image acquisition was performed at the time point with portal venous contrast distribution of CA 1 and arterial contrast phase for CA 2. Therefore, a contrast injection protocol was planned with sequential injection of CA 1 and CA 2 to provide a time dependent difference in contrast distribution of both CAs in the vessels and parenchyma of the liver. Native, arterial, and portal venous contrast enhanced images have been calculated based on the spectral separation of PCCT. In simulated PCCT images, we were able to differentiate between the tissue enhancement of CA 1 and CA 2. The distribution of both CA within the parenchyma of the liver was illustrated with perfusion maps for CA 1 and CA 2. In addition, virtual non contrast enhanced image were calculated. In conclusion, multi-phase PCCT imaging of the liver based on a single scan is a novel approach for spectral PCCT imaging, offering detailed contrast information in a single scan volume and a significant reduction of radiation dose.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT
    Greffier, Joel
    Villani, Nicolas
    Defez, Didier
    Dabli, Djamel
    Si-Mohamed, Salim
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (04) : 167 - 177
  • [32] Tungsten-Based Contrast Agent for Photon-Counting Detector CT Angiography in Calcified Coronaries
    Sartoretti, Thomas
    McDermott, Michael C.
    Stammen, Lion
    Martens, Bibi
    Moser, Lukas J.
    Jost, Gregor
    Pietsch, Hubertus
    Gutjahr, Ralf
    Nowak, Tristan
    Schmidt, Bernhard
    Flohr, Thomas G.
    Wildberger, Joachim E.
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2024, 59 (10) : 677 - 683
  • [33] Advanced Imaging Technology: Photon Counting CT
    Jalal, Sabeena
    Nicolaou, Savvas
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2024, 75 (01): : 20 - 21
  • [34] Abdominal applications of photon-counting CT
    Khanungwanitkul, Khanin
    Sliwicka, Olga
    Schwartz, Fides Regina
    BRITISH JOURNAL OF RADIOLOGY, 2024,
  • [35] Photon counting CT: Effects of dynamic beam attenuator on image quality
    Atak, Haluk
    Shikhaliev, Polad M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 867 : 58 - 71
  • [36] Eigenbin compression for reducing photon-counting CT data size
    Schmidt, Taly Gilat
    Yin, Zhye
    Yao, Jingwu
    Fan, Jiahua
    MEDICAL PHYSICS, 2024, : 8751 - 8760
  • [37] Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
    Booij, Ronald
    van der Werf, Niels R.
    Dijkshoorn, Marcel L.
    van der Lugt, Aad
    van Straten, Marcel
    DIAGNOSTICS, 2022, 12 (06)
  • [38] Minimizing Contrast Media Dose in CT Pulmonary Angiography with Clinical Photon Counting Using High Pitch Technique
    Saeed, Saher
    Niehoff, Julius H.
    Boriesosdick, Jan
    Michael, Arwed
    Woeltjen, Matthias M.
    Surov, Alexey
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    ACADEMIC RADIOLOGY, 2024, 31 (02) : 686 - 692
  • [39] Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT
    Stephan Rau
    Alexander Rau
    Thomas Stein
    Muhammad Taha Hagar
    Sebastian Faby
    Fabian Bamberg
    Jakob Weiss
    La radiologia medica, 2024, 129 : 669 - 676
  • [40] Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT
    Rau, Stephan
    Rau, Alexander
    Stein, Thomas
    Hagar, Muhammad Taha
    Faby, Sebastian
    Bamberg, Fabian
    Weiss, Jakob
    RADIOLOGIA MEDICA, 2024, 129 (04): : 585 - 597