Comparison of visual, automatic and semiautomatic methods to determine ventilatory indices in 50 to 60 years old adults

被引:5
作者
Puehringer, Martin [1 ]
Ring-Dimitriou, Susanne [1 ]
Stoeggl, Thomas [1 ]
Iglseder, Bernhard [2 ]
Paulweber, Bernhard [3 ]
机构
[1] Univ Salzburg, Dept Sport & Exercise Sci, Salzburg, Austria
[2] Paracelsus Private Med Univ, Dept Geriatr Med, Christian Doppler Klin, Salzburg, Austria
[3] Paracelsus Private Med Univ, Dept Internal Med, Salzburg, Austria
关键词
Aerobic Capacity; cardio Pulmonary; exercise Physiology; exercise Testing; GAS-EXCHANGE; ANAEROBIC THRESHOLD; EXERCISE; RELIABILITY;
D O I
10.1080/02640414.2020.1725993
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to compare different methods of detecting ventilatory indices (VI) and to investigate the impact of cardiorespiratory fitness (CRF) level on VI detection. Fifty females and fifty males completed a graded exercise test until volitional exhaustion with continuous gas-exchange measurement. The first and second ventilatory indices (VI-1, VI-2) were detected through different single automatic methods and through a semiautomatic method which combines visual and automatic detection methods. Additionally, the VIs were detected visually by two experts which served as the study specific gold standard. When comparing the semiautomatic method at VI-1 (intraclass correlation coefficients (ICC) 0.88 [0.81, 0.92], Bland-Altman bias +/- limits of agreement (LoA) 55 +/- 334 ml O-2 center dot min(-1)) and VI-2 (ICC 0.97 [0.96, 0.98], LoA 1 +/- 268 ml O-2 center dot min(-1)) to the visually detected VI, high levels of agreements and no significant differences were found. This was not the case for any of the other automatic methods. Additionally, we couldn't find any relevant differences regarding the CRF level. We therefore concluded that the semiautomatic detection method should be used for VI detection, as results are more accurate than in any of the single-automatic methods.
引用
收藏
页码:692 / 702
页数:11
相关论文
共 27 条
  • [1] American College of Sports Medicine, 2013, GUID EX TEST PRESCR
  • [3] A NEW METHOD FOR DETECTING ANAEROBIC THRESHOLD BY GAS-EXCHANGE
    BEAVER, WL
    WASSERMAN, K
    WHIPP, BJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (06) : 2020 - 2027
  • [4] Methodological approach to the first and second lactate threshold in incremental cardiopulmonary exercise testing
    Binder, Ronald K.
    Wonisch, Manfred
    Corra, Ugo
    Cohen-Solal, Alain
    Vanhees, Luc
    Saner, Hugo
    Schmid, Jean-Paul
    [J]. EUROPEAN JOURNAL OF CARDIOVASCULAR PREVENTION & REHABILITATION, 2008, 15 (06): : 726 - 734
  • [5] Statistical methods for assessing agreement between two methods of clinical measurement
    Bland, J. Martin
    Altman, Douglas G.
    [J]. INTERNATIONAL JOURNAL OF NURSING STUDIES, 2010, 47 (08) : 931 - 936
  • [6] COHEN J., 1969, Statistical power analysis
  • [7] Evidence of break-points in breathing pattern at the gas-exchange thresholds during incremental cycling in young, healthy subjects
    Cross, Troy J.
    Morris, Norman R.
    Schneider, Donald A.
    Sabapathy, Surendran
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (03) : 1067 - 1076
  • [8] Dolezal BA, 2017, J SPORT SCI MED, V16, P396
  • [9] Do regression-based computer algorithms for determining the ventilatory threshold agree?
    Ekkekakis, Panteleimon
    Lind, Erik
    Hall, Eric E.
    Petruzzello, Steven J.
    [J]. JOURNAL OF SPORTS SCIENCES, 2008, 26 (09) : 967 - 976
  • [10] G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    Faul, Franz
    Erdfelder, Edgar
    Lang, Albert-Georg
    Buchner, Axel
    [J]. BEHAVIOR RESEARCH METHODS, 2007, 39 (02) : 175 - 191