Accuracy of field alignment in abdominal radiation therapy

被引:6
|
作者
Kortmann, RD
Hess, CF
Meisner, C
Schmidberger, H
Bamberg, M
机构
[1] UNIV TUBINGEN, DEPT RADIOTHERAPY, D-72076 TUBINGEN, GERMANY
[2] UNIV TUBINGEN, INST MED INFORMAT PROC, D-72076 TUBINGEN, GERMANY
关键词
radiation therapy; quality assurance; verification films; patient positioning; seminoma;
D O I
10.1016/0360-3016(96)00152-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the accuracy of field alignment in a homogeneous group of patients undergoing radiotherapy of the abdomen (adjuvant treatment of the paraaortic region in Stage I testicular seminoma), To evaluate the predictive value of the first verification on field placement errors during subsequent treatment delivery, Methods acid Materials: In 45 patients, linear and rotational discrepancies were measured between simulation and first check and between 10 consecutive verification films, Results: For the total group of patients, the distribution of all deviations showed mean values between 2.3 mm and -2.7 mm with standard deviations of 3.9 mm to 4.7 mm for linear discrepancies, and -0.5 degrees to 0.3 degrees with standard deviations of 1.2 degrees to 2.1 degrees for rotational discrepancies, respectively. For ail patients, deviations for the transition from simulator to the treatment machine were similar to deviations during subsequent treatment delivery, with 95% of all absolute deviations < 10.0 mm and 4 degrees, respectively, When performing correlation analysis between deviations at first check and during treatment delivery, a correlation for lateral displacements and a borderline correlation for caudal displacements could be found, There was no correlation for cranial and rotational displacements, Conclusions: Although a trend of deviations for subsequent treatment delivery may be shown at first check, our analysis indicates that the first verification cannot reliably predict inaccuracies during treatment delivery, Random fluctuations of field displacements of up to 1.0 cm prevail, They must be considered when prescribing the safety margins of the planned target volume and determining cutoff points for corrective actions in abdominal radiation therapy.
引用
收藏
页码:779 / 783
页数:5
相关论文
共 50 条
  • [21] Setup Time and Positioning Accuracy in Breast Radiation Therapy Using Surface Guided Radiation Therapy
    Kost, S.
    Shah, C. S.
    Xia, P.
    Guo, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E481 - E482
  • [22] Analysis of mechanical sources of patient alignment errors in radiation therapy
    Wyman, DR
    Ostapiak, OZ
    Gamble, LM
    MEDICAL PHYSICS, 2002, 29 (11) : 2698 - 2704
  • [23] Professional field of radiation therapy - Radiation Oncology.
    Lukas, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (01) : 71 - 71
  • [24] Will AI Improve Tumor Delineation Accuracy for Radiation Therapy?
    Chang, Zheng
    RADIOLOGY, 2019, 291 (03) : 687 - 688
  • [25] WORKSHOP ON GEOMETRIC ACCURACY AND REPRODUCIBILITY IN RADIATION-THERAPY
    REINSTEIN, LE
    MEEK, AG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (05): : 809 - 810
  • [26] Accuracy of Marketing Claims by Providers of Stereotactic Radiation Therapy
    Narang, Amol K.
    Lam, Edwin
    Makary, Martin A.
    DeWeese, Theodore L.
    Pawlik, Timothy M.
    Pronovost, Peter J.
    Herman, Joseph M.
    JOURNAL OF ONCOLOGY PRACTICE, 2013, 9 (01) : 57 - +
  • [27] Sweet syndrome in a field of radiation therapy
    Wanat, Karolyn A.
    Kovarik, Carrie L.
    Quon, Harry
    Miller, Christopher J.
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2012, 67 (06) : E284 - E286
  • [28] A Comparison of Field-in-Field and Intensity Modulated Radiation Therapy in Delivering Hypofractionated Radiation Therapy for Prostate Cancer
    Ghafour, Hawbir
    Ali, Jalil S.
    Ali, Ronak Taher
    Sirelkhatim, Elhussien
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (02)
  • [29] Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy
    Cheung, Joey P.
    Shugard, Erin
    Mistry, Nilesh
    Pouliot, Jean
    Chen, Josephine
    MEDICAL PHYSICS, 2019, 46 (02) : 892 - 901
  • [30] Has the use of computers in radiation therapy improved the accuracy in radiation dose delivery?
    Van Dyk, J.
    Battista, J.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489